Skip to main content
Log in

Beam purification techniques for low energy rare isotope beams from a gas cell

  • Published:
Hyperfine Interactions Aims and scope Submit manuscript

Abstract

A linear gas stopping cell has been implemented at the NSCL as part of the Low Energy Beam and Ion Trap (LEBIT) facility. The gas stopping cell is used to convert relativistic ions into low energy ions suitable for use in ion trap experiments. A common undesired property of such systems is the production of beam contaminants through charge exchange of gas impurities with the He +  ions produced in the stopping process. These contaminants are of particular concern for Penning trap mass spectrometry, where the simultaneous trapping of ions with different masses can cause unwanted shifts in the measured cyclotron frequency of the desired ions. In order to minimize such effects, a multi-stage beam purification system has been implemented at LEBIT.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Morrissey, D.J., et al.: Nucl. Instrum. Methods Phys. Res. Sect. B 204, 90 (2003)

    Article  ADS  Google Scholar 

  2. Weissman, L., et al.: Nucl. Phys. A 746, 655c–658c (2004)

    Article  ADS  Google Scholar 

  3. Weissman, L., et al.: Nucl. Instrum. Methods B 540, 245 (2005)

    Article  Google Scholar 

  4. Facina, M., et al.: doi:10.1007/s10751-007-9559-7, these proceedings

  5. Brubaker, W.M.: Adv. Mass Spectrom. 4, 293 (1968)

    Google Scholar 

  6. Fu, Y.-J., et al.: Int. J. Mass Spectrom. 255-256, 102–110 (2006)

    Article  Google Scholar 

  7. Jasik, J., et al.: Int. J. Mass Spectrom. 249-250, 162–170 (2006)

    Article  Google Scholar 

  8. Boxford, W.E., et al.: Int. J. Mass Spectrom. 244, 60–64 (2005)

    Article  Google Scholar 

  9. Schwarz, S., et al.: Nucl. Instrum. Methods B 204, 474 (2003)

    Article  ADS  Google Scholar 

  10. Bollen, G., et al.: Phys. Rev. Lett. 96, 152501 (2006)

    Article  ADS  Google Scholar 

  11. Schwarz, S., et al.: The LEBIT Facility at MSU High-Precicion Mass Measurements at a Fragmentation Facility: doi:10.1007/s10751-007-9549-9, these proceedings

  12. Guan, S., Marshall, A.: Int. J. Mass Spectrom. Ion Process. 157-158, 5 (1996)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. Schury.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schury, P., Bollen, G., Block, M. et al. Beam purification techniques for low energy rare isotope beams from a gas cell. Hyperfine Interact 173, 165–170 (2006). https://doi.org/10.1007/s10751-007-9553-0

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10751-007-9553-0

Keywords

Navigation