Skip to main content
Log in

Analyzing the Operating Modes of a Single-Phase Autotransformer in a Three-Phase Bank of Single-Phase Transformers

  • Published:
Power Technology and Engineering Aims and scope

Currently, the operation of three-phase banks of single-phase transformers and autotransformers requires keeping an identical single-phase unit in reserve. In this case, an emergency situation may arise where it is necessary to replace the transformer in one of the phases, but there is a single-phase unit with different characteristics rather than an identical unit. The possibility of such a connection of a transformer bank is tested numerically.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A. I. Vol’dek, Electrical Machines [in Russian], Énergiya, Leningrad (1978).

  2. S. D. Lizunov and A. K. Lokhanin (eds.), Power Transformers [in Russian], Énergoizdat, Moscow (2004).

    Google Scholar 

  3. L. V. Leites, Electromagnetic Design of Transformers and Reactors [in Russian], Énergiya, Moscow (1981).

    Google Scholar 

  4. S. G. Tiguntsev, S. B. Akhmedov, A. T. Turdiev, and M. A. Sherkunkov, “On the article Possibility of decreasing the induced voltage on a repair work site,” Élektr. Stantsii, No. 1, 34 – 38 (2019).

    Google Scholar 

  5. Standard GOST R 52719–2007. Power Transformers. General Specifications [in Russian], Standartinform, Moscow (2007).

  6. Standard GOST 30830–2002 (IEC 60076-1–93). Power Transformers [in Russian], IPK Izd. Standartov, Moscow (2003).

  7. Standard GOST 26044–83. Vibration. Equipment for Operational Monitoring of Vibration of Power-Generating Hydroturbine Units. General Specifications [in Russian], Gosstandart, Moscow (1984).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. G. Tiguntsev.

Additional information

Translated from Élektricheskie Stantsii, No. 6, June 2023, pp. 25 – 28. DOI: https://doi.org/10.34831/EP.2023.1103.6.005

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tiguntsev, S.G., Vishnyakov, D.A. & Vishnyakov, N.A. Analyzing the Operating Modes of a Single-Phase Autotransformer in a Three-Phase Bank of Single-Phase Transformers. Power Technol Eng 57, 629–632 (2023). https://doi.org/10.1007/s10749-024-01711-3

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-024-01711-3

Keywords

Navigation