Revisiting the Method of Designing Salt Equalization Lines between the Saline Compartments of Drum Boilers of Thermal Power Plants

  • Published:
Power Technology and Engineering Aims and scope

A method for designing salt equalization lines (SEL) in two-sided external saline compartments (SC) with allowance for natural circulation is described. If there is heat imbalance between the left and right SCs, the SEL cannot eliminate the salt imbalance between them because of the natural circulation in the two-sided SCs. The method was validated experimentally for TG-104 boiler with SELs: salt imbalance occurred between the SCs after artificial creation of heat imbalance between the left and right waterwalls of the saline compartments.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Technical Guides RTM 108.030.05–75. Design of Internal Layouts and Drum Internals of High-Pressure Boilers [in Russian], Ministerstvo Énerg. Mashinostr., Moscow (1975).

  2. I. I. Belyakov, A. F. Belokonova, and A. V. Mikhailova, “Studying the causes of damage to waterwall tubes of HP drum boilers,” Élektr. Stantsii, No. 6, 30 – 34 (1980).

    Google Scholar 

  3. I. I. Belyakov, “Staged evaporation in high-pressure boilers,” Énergosber. Vovopodgot., No. 2, 41 – 44 (2000).

    Google Scholar 

  4. I. I. Belyakov, “Analysis of internal layout of high-pressure drum boilers,” Power Techol. Eng., 39(1), 38 – 43 (2005).

    MathSciNet  Google Scholar 

  5. V. S. Shchetkin, “Testing the circulation in the side and back waterwalls of the head BKZ-420-140NGM close-coupled boiler,” Élektr. Stantsii, No. 3, 21 – 24 (1978).

    Google Scholar 

  6. A. I. Fedorov, “Studying the causes of damage to waterwall tubes of the external saline compartment of the TPE-208 boiler of a 210 MW power unit,” Teploénergetika, No. 4, 17 – 22 (2003).

    Google Scholar 

  7. A. I. Fedorov, D. A. Baev, and V. A. Batorshin, “Studying the effect of gas consumption imbalance among burners on the salt concentration distribution in the furnace panels of a high-pressure drum boiler,” in: Proc. 7th Int. Sci.-Tech., Conf. on Water Conditioning and Chemistry at TPP: Purposes and Tasks [in Russian], OAO VTI, Moscow (2020), pp. 41 – 46.

  8. Regulation Document RD 24.031.121–2012. Equipping Stationary Steam Boilers with Steam and Water Sampling Devices [in Russian], NPO TsKTI, St. Petersburg (2012).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. I. Fedorov.

Additional information

Translated from Élektricheskie Stantsii, No. 3, March 2021, pp. 17 – 22. DOI: 10.34831/EP.2021.1076.3.003

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Fedorov, A.I. Revisiting the Method of Designing Salt Equalization Lines between the Saline Compartments of Drum Boilers of Thermal Power Plants. Power Technol Eng 55, 408–413 (2021). https://doi.org/10.1007/s10749-021-01374-4

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-021-01374-4

Keywords

Navigation