In 2019, the fourth 110 MW combined-cycle power unit was commissioned at the Pregolskaya Thermal Power Plant (TPP), the Kaliningradskaya CHP-2 branch of the Inter RAO-Electric Power Plants company. The PGU-110 power unit includes a 77.85 MWgas turbine PG6111FA(manufactured by General Electric) delivered by the Russian Gas Turbines company. Natural gas is used as fuel in the combustion chamber. Detailed tests and studies of the operating modes of the gas turbine in a wide range were carried out in the same year. The test results are presented, and the thermal characteristics of the gas turbine are specified. During the tests, the standard automated measurement system was used. More than 60 stationary modes at various electrical loads and ambient temperatures were studied. The experimental data were processed following State Standard GOST R 55798–2013 (Gas Turbine Installations. Test Methods. Acceptance Tests) and special heat-balance methods. During the tests, the electrical output of the gas turbine varied from 80.1 to 17 MW in the range of external temperatures from +2 to +21°C, while the initial gas temperature in the turbine decreased from 1220 to 1000°C. In the range of loads studied, the NOx emissions at 15% O2 did not exceed 10 ppm.
Similar content being viewed by others
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Élektricheskie Stantsii, No. 3, March 2021, pp. 12 – 15. DOI: 10.34831/EP.2021.1076.3.001
Rights and permissions
About this article
Cite this article
Ageev, A.V., Rozhkov, A.D., Frolov, M.S. et al. Results of Thermal Testing and Characteristics of 78 MW Gas-Turbine Unit. Power Technol Eng 55, 404–407 (2021). https://doi.org/10.1007/s10749-021-01373-5
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10749-021-01373-5