Recognizing Ability of Local Currents During Two-Side Observation of Transmission Line

  • Published:
Power Technology and Engineering Aims and scope

The article is aimed at analyzing the various information and parameters involved in diagnosing the fault location on the power line and identifying the damaged branch if there are several branches. Relay protection algorithms widely use the separation of the short-circuit current into the previous and emergency components. The latter carries the basic information of the fault location. Recently, it was found that the emergency component can also be divided into two components, namely normal and local. The local component is particularly very important because the ratio of local currents shows a strong dependence on the fault location or on the damaged branch, but does not depend on the fault current and, most importantly, does not on the part of the electrical system external to the observed line. The influence of unobserved branches on the accuracy of determining the damaged location by the proposed measurement is analyzed. Attention is drawn to the correlation between local currents algorithm and the emerging trends in merging or unifying the characteristics of relay protection and automation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. I. N. Popov, V. F. Lachugin, and G. V. Sokolova, Relay Protection Based on the Control of Transient Processes [in Russian], Énergoatomizdat, Moscow (1986).

  2. M. Fikri, M. El-Sayed, “New algorithm for distance protection of high voltage transmission lines,” IEE Proc., 135(5), 436 – 440 (1988).

    Google Scholar 

  3. Yu. Ya. Lyamets, A. A. Belyanin, and P. I. Voronov, “Modifications of the emergency components of the observed currents and voltages,” Élektrotekhnika, No. 2, 22 – 28 (2015).

  4. Yu. Ya. Lyamets, A. A. Belyanin, “Components of short-circuit currents in the observed electrical network,” Élektrotekhnika, No. 10, 40 – 44 (2016).

  5. C. Sungyun, A. P. Meliopoulos, “Setting-less transformer protection for ensuring security and dependability,” Elec. Eng., 98(3), 283 – 297 (2016).

    Google Scholar 

  6. Yu. Ya. Lyamets, M. V. Martynov, A. N. Maslov, I. Yu. Nikonov, “Unification of the characteristics of the damage indicator on the controlled section of the power transmission line,” Izv. RAN. Énerget., No. 1, 123 – 134 (2019).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ivan Kochetov.

Additional information

Translated from Élektricheskie stantsii, No. 6, June 2020, pp. 54 – 58.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kochetov, I., Liamets, Y.Y. & Makashkin, F.A. Recognizing Ability of Local Currents During Two-Side Observation of Transmission Line. Power Technol Eng 54, 600–604 (2020). https://doi.org/10.1007/s10749-020-01258-z

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-020-01258-z

Keywords

Navigation