The effect of CSR on voltage harmonics in high-voltage electrical networks is considered. An An applied method of modeling an electrical network in order to calculate the CSR effect on voltage harmonics is proposed. The results of calculations of the CSRT effect on the quality indicators of electric power are presented in the frequency domain, as well results of computer modeling of transient electromagnetic processes in a network with CSRT. Calculations for the experimental datas obtained in the commissioning of the CSRT at the 330 kV Starorusskaya SS were verified.
Similar content being viewed by others
References
M. V. Dmitriev, A. S. Karpov, E. B. Sheskin, et al., Controlled Shunt Reactors [in Russian], Rodnaya Ladoga, St. Petersburg (2013).
A. M. Matinyan, M. V. Peshkov, V. N. Karpov, N. A. Alekseev, V. A. Padalko, A. V. Antonov, and P. Yu. Bulykin, “Fast controlled shunt reactors for application in the UES of Russia and abroad,” Énergiya Edin. Seti, No. 3, 38 – 44 (2017).
A. M. Matinyan, M. V. Peshkov, V. N. Karpov, and N. A. Alekseev, “Harmonic composition of currents of network windings in a 500 kV CSRT with split valve windings,” Élektr. Stantsii, No. 4, 45 – 48 (2016).
State Standard GOST 32144–2013. Quality Standards of Electric Power in General Purpose Networks [in Russian].
J. Airillaga and N. R. Watson, Power System Harmonics, John Wiley & Sons, (2003).
C. J. Das, Power System Analysis: Short-Ciruit Load Flow and Harmonics, Marcel Dekker, (2002).
X. A. Wenyuan, A Multiphase Harmonic Load Flow Solution Technique. Ph.D. dissertation. https://open.library.ubc.ca/circle/collections/ubctheses/831/items/l.0065647, British Columbia (1990).
W. T. Wiechowski, Harmonics in Transmission Power Systems. Ph.D. dissertation. https://vbn.aau.dk/files/316398306/wojciechwiechowski.pdf, Denmark (2006).
Task Force On Harmonics Modeling and Simulation. Tutorial on Harmonics Modeling and Simulation, IEEE Publication TP-125-0 (1998).
RD 34.20.577. Methodical Directions to Determine the Stability of Electric Power Systems. Part 1 [in Russian].
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Élektricheskie Stantsii, No. 5, May 2020, pp. 47 – 53.
Rights and permissions
About this article
Cite this article
Matinyan, A.M., Koshelev, K.S., Kiselev, A.N. et al. Modern CSR with Split Valve Windings: Calculation of Harmonics and their Verification According to Experimental Data. Power Technol Eng 54, 581–587 (2020). https://doi.org/10.1007/s10749-020-01255-2
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10749-020-01255-2