Calculation of the Admissible Short Circuit Current for the Protected Wires of an OHL

  • Published:
Power Technology and Engineering Aims and scope

Polymer materials used in protected wires are very sensitive to the temperature increase that occurs in the course of a short circuit (SC) current. Heating the insulation of the wire above the admissible temperature for it may make it necessary to replace the damaged wires. A methodology is proposed for calculating the admissible SC current for the protected wires of an OHL, taking into account the periodic and aperiodic components of the SC current. The materials of this article can be used in designing and using lines made with protected wires.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Wire with Protective Insulation for 110 kV Power Transmission Lines (SIP-7) [in Russian]. http://sevcable.ru/catalog/mark?id=1331&categoryld=303.

  2. Y. Ojala, T. Leskinen, M. Lahtinen, and A. Hinkkuri, “110 kV overhead transmission line with covered conductors,” in: Proc. of the 1998 CIGRE Session. Paper 22_33_36-10, CIGRE Study Committee 22 (1998).

  3. Wires with Protective Insulation for 35 kV Power Transmission Lines, PZV and PZVG brand [in Russian]. http://www.suetcahle.ru/wire/sevcahel/lep/pzv-pzvg.htm.

  4. GOST R 52736–2007. Short Circuits in Electrical Installations. Calculation Methods of Electrodynamics and Thermal Effect of a Short-Circuit Current [in Russian], Standartinform, Moscow (2007).

  5. GOST R 52373–2005. Self-Supporting Insulated and Protected Wires for Overhead Power Lines. General Specifications [in Russian], http://docs.cntd.ru/document/1200041198.

  6. Protected Wire for Overhead Power Lines, PAS AAA and PAS AAA-WR brands [in Russian]. http://www.impx.ru/files/tovary/pdf_catalogue_catalogue_124.pdf.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. P. Vikharev.

Additional information

Translated from Élektricheskie Stantsii, No. 4, April 2018, pp. 36 – 39.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Vikharev, A.P. Calculation of the Admissible Short Circuit Current for the Protected Wires of an OHL. Power Technol Eng 52, 357–360 (2018). https://doi.org/10.1007/s10749-018-0959-4

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-018-0959-4

Keywords

Navigation