To detect phase wire breaks in a 6 – 10 kV overhead line, the negative-sequence voltage on the low-tension side of the 6 – 10/0.4 kV power transformer can be used. The results of studying the effect of a phase wire break in an overhead line, phase displacement groups, and phase unbalance of demand loads in a 380 V network on the negative-sequence voltage are presented. A device for signaling phase wire breaks in a 6 – 10 kV overhead line is described. The device is based on a microprocessor electricity meter installed on the low-tension side of a 6 – 10/0.4 kV power transformer.
Similar content being viewed by others
References
A. V. Grigor’ev, A. I. Selivakhin, and V. I. Sukmanov, Protection of Rural Electric Networks [in Russian], Kainar, Alma-Ata (1984).
A. M. Manilov, “Protection of a 6 – 35 kV network after break of a phase and fall of the wire on the ground,” Énergetik, No. 11, 22 – 23 (2003).
Regulations for the Uniform Technical Policy of JSC Russian Grids in the Distribution Grid Sector [in Russian], JSC Rosseti, Moscow (2013).
A. M. Ershov, A. V. Khlopova, and N. Yu. Khabarov, “Classification of wire-break protection of 6 – 10 kV overhead lines,” in: Proc. 68th Sci. Conf. Engineering Science Sections [in Russian], YuUrGU, Chelyabinsk (2016), pp. 784 – 791.
USSR Inventor’s Certificate 792439, IPC H02H3/16, H02H5/10/; R. Sh. Sagutdinov, A. I. Selivakhin, A. P. Kuznetsov, and F. D. Kuznetsov, “Device for unbalance protection of a section of overhead transmission line with isolated neutral,” Byull. Otkryt. Izobret., No. 48 (1980).
A. I. Fedotov, G. V. Vagapov, N. V. Rozhentsova, and R. E. Abdullazyanov, “Detection of wire breaks and single-phase earth faults in distribution networks from the parameters of the 0.4 kV side of step-down substations,” Promyshl. Énerget., No. 4, 34 – 40 (2016).
S. A. Ul’yanov, Electromagnetic Transients in Electric Systems [in Russian], Énergiya, Moscow (1970).
F. D. Kosouhov and I. V. Naumov, Unbalanced Voltages and Currents in Rural Distribution Networks [in Russian], Izd. IrGSKhA, Irkutsk (2003).
A. V. Khlopova and A. M. Ershov, “Numerical model for studying operating modes of 6 – 10 kV/0.38 kV network,” in: Proc. 68th Sci. Conf. Nauka YuUrGU. Engineering Science Sections [in Russian], YuUrGU, Chelyabinsk (2016), pp. 799 – 805.
A. M. Ershov and A. V. Khlopova, “Physical model of a 10/0.38 kV network,” Élektrobezopasnost’, No. 2, 13 – 21 (2016).
A. V. Mlotok, A. M. Ershov, R. G. Valeev, and A. I. Sidorov, “Test 380 V network,” Vestn. Inzh. Shkoly DVFU, No. 2(19), 96 – 107 (2014).
V. G. Tynyanskii, Recognition of Operating Modes of 0.4 kV Overhead Lines and Consumers. Author’s Abstract of Candidate’s Thesis [in Russian], YuRGTU, Novocherkassk (2005).
RF Pat. No. 2633803, IPC Í02Í5/10/, No. 2017102432, A. M. Ershov, O. V. Filatov, A. V. Khlopova, A. V. Zaporozhskii, R. G. Valeev, and A. I. Sidorov, “A wire-break protection device for overhead transmission lines with isolated neutral,” appl. Jan. 25, 2017; publ. October 19, 2017; Byull., No. 29 (2017).
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Élektricheskie Stantsii, No. 12, December 2017, pp. 34 – 40.
Rights and permissions
About this article
Cite this article
Ershov, A.M., Khlopova, A.B. & Sidorov, A.I. Phase Wire Break Signaling for 6 – 10 kV Overhead Line. Power Technol Eng 52, 110–115 (2018). https://doi.org/10.1007/s10749-018-0918-0
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10749-018-0918-0