The major results of a study of the temperature state of the flow-through part of a T-125/150 PGU-450 turbine operating in the steam-free and motor regimes are reported. A scheme for transfer of the turbine into the motor regime is proposed.
Similar content being viewed by others
References
E. K. Arakelyan and V. A. Starshinov, Increasing the Efficiency and Maneuverability of Thermal Power Plant Equipment [in Russian], Izd. MÉI, Moscow (1993).
A. A. Madoyan, B. L. Levchenko, E. K. Arakelyan, et al., Use of the Motor Mode at Thermal Power Plants [in Russian], Énergiya, Moscow (1980).
E. K. Arakelyan and K. V. Sakharov, “Astudy of the temperature state of the HPC stages of a T-125/150 PGU-450 turbine during lowsteam operation,” Novoe Ross. Élektroénerg., No. 1 (2013).
A. G. Kostyuk and V. V. Frolov, Turbines for Thermal and Nuclear Power Plants [in Russian], Izd. MÉI, Moscow (2001).
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Élektricheskie Stantsii, No. 6, June 2015, pp. 21 – 26.
Rights and permissions
About this article
Cite this article
Arakelyan, É.K., Bezdelgin, I.O. & Andryushin, K.A. Temperature State of the Flow-Through Part of a T-125/150 PGU-450 Steam Turbine Operating in the Steam-Free and Motor Regimes. Power Technol Eng 49, 291–295 (2015). https://doi.org/10.1007/s10749-015-0617-z
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10749-015-0617-z