Assessing the Possibility of Participation of Cross-Connection Thermal Power Plants in Assigned-Reserve Primary Frequency Control

  • THERMAL POWER PLANTS
  • Published:
Power Technology and Engineering Aims and scope

The results of tests conducted at the Tobolsk CHPP confirm that cross-connection thermal power plants can participate in assigned-reserve primary frequency control and automatic secondary frequency and power-flow control.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Company Standard STO 59012820.27.100.002–2005. Standard Requirements for Participation of TPP Units in Assigned-Reserve Primary Frequency Control and Automatic Secondary Frequency Control [in Russian], Izd. JSC “SO UPS,” Moscow (2005).

  2. Company Standard STO 59012820.27.100.002–2012. Standard Requirements for Participation of Combined-Cycle Power Units in Assigned-Reserve Primary Frequency Control and Automatic Secondary Frequency and Real Power Flow Control [in Russian], Izd. JSC “SO UPS,” Moscow (2012).

  3. Company Standard STO 59012820.27.100.002–2013.Standard Requirements for Participation of Units of Thermal Power Plants in Assigned-Reserve Primary Frequency Control and Automatic Secondary Frequency and Power Flow Control [in Russian], Izd. JSC “SO UPS,” Moscow (2013).

  4. State Standard GOST 55890–2013. United Power System and Isolated Power Systems. Operational Dispatching Control. Frequency and Real Power Flow Control. Regulations and Requirements [in Russian], Standartinform, Moscow (2014).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to N. V. Zorchenko.

Additional information

Editorial Note

The possibility of participation of cross-connection TPPs in assigned-reserve primary frequency control (APFC) is of interest for a wide range of experts engaged in the development, design, introduction, and operation of automatic control systems. Since the facilities under consideration are various and complex, interested readers are welcome to send us information on experience and questions, remarks, and proposals regarding the participation of cross-connection TPPs in APFC and/or ASFPC.

Translated from Élektricheskie Stantsii, No. 5, May 2015, pp. 11 – 15.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zorchenko, N.V., Krylov, V.Y. Assessing the Possibility of Participation of Cross-Connection Thermal Power Plants in Assigned-Reserve Primary Frequency Control. Power Technol Eng 49, 278–282 (2015). https://doi.org/10.1007/s10749-015-0614-2

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-015-0614-2

Keywords

Navigation