An atmospheric pressure deaerator with a capacity of 500 tons/h has been designed for use in the heat supply system at the JSC “South-West Power Plant”. It employs superheated (relative to the saturation temperature for the pressure in the deaerator) water with a temperature of 130 – 150°C as a heat transfer medium. Tests and operational data of the new DA-500/100 deaerator show that it operates stably, reliably, and efficiently within the design range of hydraulic and thermal loads, while the quality of the feed water after it meets the standards. The DA-500/100 deaerator with superheated water as the heat transfer medium is recommended for use in large heat supply systems in heating and electric power plants and boiler plants.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Atmospheric and High Pressure Deaerators: Catalog-Handbook 18-7-71 [in Russian], Izd. NIIInformTYaZhMaSh, Moscow (1972).

  2. State Standard GOST 16860–71. Thermal deaerators [in Russian].

  3. State Standard GOST 16860–77. Thermal deaerators [in Russian].

  4. State Standard GOST 16860–88. Thermal deaerators [in Russian], Standartinform, Moscow (2007).

  5. Heat-Exchange Equipment for Industrial Installations and Heat Supply Systems: Industrial Catalog 04004 [in Russian], Izd. VNIIAM, NPO CKTI, Moscow (2004).

  6. A. S. Gimmelberg, V. G. Mikhailov, A. N. Baeva, and D. M. Donder”, A new design for atmospheric pressure deaerators for large heat supply systems,” Tyazh. Mashinostr., No. 10 (2002).

  7. A. S. Gimmelberg, V. G. Mikhailov, G. V. Grigorev, L. A. Khomenok, P. V. Egorov, N. E. Shilova, and B. M. Sokolov, “Deaerator with a small sized deaeration column for 300-MW power generating units,” Élektr. Stantsii, No. 4 (2006).

  8. G. V. Grigorev, A. S. Gimmelberg, P. V. Egorov, N. E. Shilova, V. G. Mikhailov, and A. N. Baeva, “Large scale thermal deaerators with a horizontal column for high-power generating units in nuclear power plants,” Teploénergetika, No. 2 (2008).

  9. Technical Operating Rules for Electric Power Plants and Grids [in Russian], Omega-L, Moscow (2003).

Download references

Author information

Authors and Affiliations

Authors

Additional information

Translated from Élektricheskie Stantsii, No. 12, December 2013, pp. 36 – 40.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Gimmelberg, A.S., Mikhailov, V.E., Mikhailov, V.G. et al. Atmospheric Pressure Deaerators for Heat Supply Systems at the South-West Power Plant. Power Technol Eng 48, 47–51 (2014). https://doi.org/10.1007/s10749-014-0482-1

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-014-0482-1

Keywords

Navigation