Abstract
Results of updating the reducer between the LPC and the condenser involving removal of lens compensators and stiffening of the bar and rib frames are presented. Air inflows into the vacuum system through cracks in welded joints of flexible elements with total welded length of 240 m are lowered considerably by replacing them by stiff sheet structures. Computations of the thermal and stress-strain states of the system are performed.
Similar content being viewed by others
References
V. F. Vlasik, A. S. Shcherbina, and V. K. Bronnikov, “Effect of end seals on the tightness of vacuum systems of VK-100-6 LMZ turbines,” Énergetik, No. 1 (1971).
V. G. Orlik, L. B. Reznik, I. A. Oksman, and I. A. Perminov, “Reduction of air inflows into condenser through end seals,” Énergetik, No. 2 (1987).
V. G. Orlik, N. V. Averkina, L. L. Vainshtein, and Yu. Ya. Kachuriner, “Effect of specific properties of wet steam on the operational reliability of turbines,” Élektr. Stantsii, No. 8 (2001).
L. L. Vainshtein, “A study of stability of three-dimensional stator structures of the low-pressure part of steam turbines,” Trudy TsKTI, Issue 254 (1989).
RTM 24.020.16-83. Design of Temperature Fields of Rotors and Casings of Steam Turbines [in Russian].
RTM 24.020.13-72. Computer-Aided Design of Turbine Cooling. Temperature Fields and Stationary Hydraulics [in Russian].
V. P. Lagun, L. L. Simoyu, Yu. V. Nakhman et al., Teploénergetika, No. 10 (1977).
Author information
Authors and Affiliations
Additional information
__________
Translated from Élektricheskie Stantsii, No. 9, September 2006, pp. 45–47.
Rights and permissions
About this article
Cite this article
Orlik, V.G., Vainshtein, L.L., Averkina, N.V. et al. Reduction of air inflows in condensers of 200-MW power units. Power Technol Eng 40, 362–364 (2006). https://doi.org/10.1007/s10749-006-0078-5