Skip to main content
Log in

Structural Performance of Prestressed Composite Members with Corrugated Webs Exposed to Fire

  • Published:
Fire Technology Aims and scope Submit manuscript

Abstract

In this study, to assess the fire performances of corrugated webbed prestressed (CWPS) composite beams exposed to fire, full-scale fire resisting tests were carried out, and fire-resisting behavioural responses of the test specimens were analyzed and compared with those obtained from nonlinear finite element analyses. Key test variables were the cover thickness of the fire protection material applied to the bottom flange of corrugated webbed steel beams, which was directly exposed to fire, and the shapes of corrugated webs. All the composite beams with fire protection material covers exposed to standard fire showed good fire-resisting capacities with fire ratings over 3 h and in particular, CWPS composite beams with relatively thin fire protection material cover thickness, compared with the non-prestressed slim-floor composite beam, satisfied the required fire performance criteria in ISO 834 standard and Eurocode. Additionally, the test results showed that the shape of corrugated webs used in CWPS composite beam specimens could have a great impact on their fire-resisting performance. The nonlinear finite element analyses performed in this study accurately estimated the overall behaviours of test specimens and especially assessed the effects of the shape of the corrugated web on the temperature distributions and fire resistance performances of CWPS composite beams appropriately.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14
Figure 15
Figure 16
Figure 17
Figure 18
Figure 19
Figure 20
Figure 21

Similar content being viewed by others

References

  1. Mullett DL (1998) Composite floor systems. Blackwell Science, London

    Google Scholar 

  2. Kim KS, Lee DH, Choi SM, Choi YH, Jung SH (2011) Flexural behavior of prestressed composite beams with corrugated web: part I. Development and analysis. Compos Part B Eng 42:1603–1616

  3. Kim KS, Lee DH (2011) Flexural behavior of prestressed composite beams with corrugated web: Part II. Experiments and verification. Compos Part B Eng 42:1617–1629

  4. Oh JY, Lee DH, Kim KS (2012) Accordion effect in prestressed steel beams with corrugated webs. ThinWall Struct 57:49–61

    Google Scholar 

  5. Oh JY, Lee DH, Cho SH, Kang H, Cho HC, Kim KS (2015) Flexural behavior of prestressed steel-concrete composite members with discontinuous webs. Adv Mater Sci Eng 2015:278293 (1–13)

  6. Easley, JT (1975) Buckling formulas for corrugated metal shear diaphragms. J Struct Div ASCE 101:1403–1417

    Google Scholar 

  7. Luo R, Edlund B (1994) Buckling analysis of trapezoidally corrugated panels using spline finite strip method. Thin Wall Struct 18:209–224

    Article  Google Scholar 

  8. Elgaaly M, Hamilton RW, Seshadri A (1996) Shear strength of beams with corrugated webs. J Struct Eng ASCE 122:390–398

    Article  Google Scholar 

  9. Azizinamini A, Barth K, Dexter R, Rubeiz C (2004) High performance steel: research front-historical account of research activities. J Bridge Eng 9:212–217

    Article  Google Scholar 

  10. Khalid Y, Chan C, Sahari B, Hamouda A (2004) Bending behaviour of corrugated web beams. J Mater Process Technol 150:242–254

    Article  Google Scholar 

  11. Abbas HH, Sause R, Driver RG (2007) Analysis of flange transverse bending of corrugated web I-girders under in-plane loads. J Struct Eng ASCE 133:347–355

    Article  Google Scholar 

  12. Mirghaderi R, Sobhan S, Torabian S (2008) In reducing beam section by corrugated webs for developing a connection of specially moment resisting frame, structures congress 2008@ sCrossing Borders, ASCE, pp 1–10

  13. Ibrahim S (2015) Steel plate girders with corrugated webs, past, present and future. Dissertation, Ain Shams University

  14. Driver RG, Abbas HH, Sause R (2006) Shear behavior of corrugated web bridge. J Struct Eng ASCE 132:195–203

    Article  Google Scholar 

  15. Lawson RM, Mullett DL, Rackham JW (1997) Design of asymmetric slimfloor beams using deep composite decking. The Steel Construction Institute, Ascot, Berks

    Google Scholar 

  16. Malaska M, Mäkeläinen P (1999) Study on composite slim floor beams. Laboratory of steel structures, Publications 9. Helsinki University of Technology, Espoo

  17. Lorenc W, Kubica E (2006) Behavior of composite beams prestressed with external tendons: experimental study. J Constr Steel Res 62:1353–1366

    Article  Google Scholar 

  18. Chen S, Gu P (2005) Load carrying capacity of composite beams prestressed with external tendons under positive moment. J Constr Steel Res 61:515–530

    Article  Google Scholar 

  19. Ayyub BM, Sohn YG, Saadatmanesh H (1990) Prestressed composite girders under positive moment. J Struct Eng ASCE 116:2931–2951

    Article  Google Scholar 

  20. Ayyub BM, Sohn YG, Saadatmanesh H (1992) Prestressed composite girders. I: experimental study for negative moment. J Struct Eng ASCE 118:2743–2762

    Article  Google Scholar 

  21. Ayyub BM, Sohn YG, Saadatmanesh H (1992) Prestressed composite girders. II: analytical study for negative moment. J Struct Eng ASCE 118:2763–2783

    Article  Google Scholar 

  22. Bae DB, Lee KM (2004) Behavior of preflex beam in manufacturing process. KSCE J Civ Eng 8:111–115

    Article  Google Scholar 

  23. Metwally AE, Loov RE (2003) Corrugated steel webs for prestressed concrete girders. Mater Struct 36:127–134

    Article  Google Scholar 

  24. Newman GM (1995) Fire resistance of slim floor beams. J Constr Steel Res 33:87–100

    Article  Google Scholar 

  25. Ma Z, Mäkeläinen P (1999) Numerical analysis of steel–concrete composite slim floor structures in fire. Laboratory of Steel Structures Publications 11. Helsinki University of Technology, Espoo

  26. Ma Z, Mäkeläinen P (2006) Structural behavior of composite slim floor frames in fire conditions. J Constr Steel Res 62:1282–1289

    Article  Google Scholar 

  27. Mäkeläinen P, Ma Z (2000) Fire resistance of composite slim floor beams. J Constr Steel Res 54:345–363

    Article  Google Scholar 

  28. Mullett DL (1992) Slim floor design and construction. The Steel Construction Institute (SCI), Ascot, Berks

  29. Mullett DL, Lawson RM (1993) Slim floor construction using deep decking. The Steel Construction Institute (SCI), Ascot, Berks

  30. Dwaikat MB, Kodur VKR (2008) A numerical approach for modeling the fire induced restraint effects in reinforced concrete beams. Fire Saf J 43:291–307

    Article  Google Scholar 

  31. ENV 1994-1-2, Eurocode 4 (2005) Design of composite steel and concrete structures. Part 1-2: general rules-structural fire design. European Committee for Standardization, Brussels

  32. ICC 2012 (2011) International building code commentary, vol 1. International Code Council

  33. ASTM (2012) E119 Standard test methods for fire tests of building construction and materials. ASTM International, West Conshohocken

    Google Scholar 

  34. KS 2257 (2005) Methods of fire resistance test for elements of building construction. Part 1: general requirements. Korean Standards Association

  35. Korea Institute of Construction Technology (KICT), www.kict.re.kr, 2014

  36. ENV 1992-1-2, Eurocode 2 (2004) Basis of design and design actions on structures. Part 1-2: Actions on structures exposed to fire. European Committee for Standardization, Brussels

  37. ISO 834 (1999) Fire resistance tests—elements of building construction. Part 1: general requirements. International Organization for Standardization

  38. Incropera FP, DeWitt DP, Bergman TL, Lavine AS (2011) Introduction to heat transfer, 6th edn. Wiley

  39. ENV 1993-1-2, Eurocode 3 (2005) Design of steel structures. Part 1-2: general rules-structural fire design. European Committee for Standardization, Brussels

  40. Gales J, Stratford T (2012) New parameters to describe high temperature deformation of prestressing steel determined using digital image correlation. Struct Eng Int’l 22:476–486

    Article  Google Scholar 

  41. Bisby L, Gales J, Maluk C (2013) A contemporary review of large-scale non-standard structural fire testing. Fire Sci Rev 2:1–27

    Article  Google Scholar 

  42. Kodur VKR, Garlock M, Iwankiw N (2012) Structures in fire: state-of-the-art, research and training needs. Fire Technol 48:825–839. doi:10.1007/s10694-011-0247-4

    Article  Google Scholar 

  43. Beneš M, Štefan R (2015) Hygro-thermo-mechanical analysis of spalling in concrete walls at high temperatures as a moving boundary problem. Int J Heat Mass Transf 85:110–134

    Article  Google Scholar 

  44. Dwaikat MB, Kodur VKR (2009) Hydrothermal model for predicting fire-induced spalling in concrete structural systems. Fire Saf J 44:425–434

    Article  Google Scholar 

  45. Jansson R (2013) Fire spalling of concrete. PhD thesis, KTH Architecture and the Built Environment

  46. Gawin D, Pesavento F (2012) An overview of modeling cement based materials at elevated temperatures with mechanics of multi-phase porous media. Fire Technol 48:753–793. doi:10.1007/s10694-011-0216-y

    Article  Google Scholar 

  47. Dwaikat MB, Kodur VKR (2010) Fire induced spalling in high strength concrete beams. Fire Technol 46:251–274. doi:10.1007/s10694-009-0088-6

    Article  Google Scholar 

  48. Franssen JM (2007) User’s manual for SAFIR 2007, a computer program for analysis of structures subjected to fire. Structural Engineering, ArGEnCO, University of Liege, Belgium

    Google Scholar 

  49. Hibbitt, Karlsson & Sorensen Inc. (2006) ABAQUS/Standard user’s manual. ABAQUS Version 6.6. Pawtucket, Rhode Island

  50. ANSYS (2012) ANSYS user manual, Version 14.0. ANSYS Inc., Cecil Township

  51. Stem-Gottfried J, Rein G (2012) Travelling fire for structural design-Part I: literature review. Fire Saf J 54:74–85

    Article  Google Scholar 

  52. Stem-Gottfried J, Rein G (2012) Travelling fire for structural design—part II: design methodology. Fire Saf J 54:74-85

    Article  Google Scholar 

Download references

Acknowledgments

This research was supported by a grant (14Industrialization_Public Technology-03) from Technology Business Innovation Program funded by Ministry of Land, Infrastructure and Transport Affairs of Korean government.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kang Su Kim.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kang, H., Lee, D.H., Hwang, JH. et al. Structural Performance of Prestressed Composite Members with Corrugated Webs Exposed to Fire. Fire Technol 52, 1957–1981 (2016). https://doi.org/10.1007/s10694-015-0521-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10694-015-0521-y

Keywords

Navigation