Results from a Full-Scale Smoke Alarm Sensitivity Study

  • Published:
Fire Technology Aims and scope Submit manuscript

Abstract

A series of 24 full-scale experiments was conducted to examine the effects of alarm type (photoelectric, ionization, and dual sensor), alarm location, fabric type (100% cotton and 100% polyester), polyurethane foam density, ignition scenario, and room configuration, on smoke alarm performance. A two-level, fractional factorial design of eight experimental configurations was developed around the five factors: fabric type, foam density, fire location, ventilation, and ignition scenario. A structure, designed to represent a single-story home or apartment, was constructed inside the Large Fire Laboratory at the National Institute for Standards and Technology for the experiments. The fire source was a chair mockup consisting of a seat and back cushion of a specific cover fabric and foam density, weighing between 5.5 kg and 8.3 kg. It rested on a metal frame and was subjected to a small propane gas flame, or an electric cartridge heater to initiate smoldering. Each experimental configuration was replicated three times. Smoldering fires were allowed to progress until they naturally transitioned to flaming fires except for one test that was terminated early due to time constraints. The smoldering to flaming transition times ranged from (81 to 182) min. Each fire progressed for a time sufficient to produce multiple hazards (smoke, heat, and toxic gases). All alarms tested were purchased from retail outlets and activated at their preset levels. Photoelectric, ionization, and dual photoelectric/ionization alarms were co-located at multiple locations to facilitate comparisons of each alarm type, and different designs of the same type of alarm. For smoke alarms in the room of fire origin, it was observed that each of the five factors had an effect on the measured alarm times that was primarily a result of fire growth rate (fabric type, foam density, and ignition scenario), or smoke dilution and transport (fire location and ventilation). The photoelectric alarm responded quicker on average than ionization alarm in two of four smoldering fire configurations, responding before the ionization alarm in all 6 trials, while the ionization alarm responded before the photoelectric alarm in two of three trials for the other two configurations. The ionization alarm responded quicker on average than photoelectric alarm in all four flaming fire configurations, and responded before the photoelectric alarm in all 12 flaming fire trials. One dual alarm had the fastest average alarm time for all four smoldering fire configurations, and responded first in 11 of the 12 trials. It also yielded faster average alarm times than the other dual alarm in seven of eight configurations, and was the first dual alarm to respond in 22 out of 23 trials where dual alarms were present.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
Figure 12

Similar content being viewed by others

References

  1. Bukowski RW, Peacock RD, Averill JD, Cleary TG, Bryner NP, Walton WD, Reneke PA, Kuligowski ED (2008) Performance of home smoke alarms, analysis of the response of several available technologies in residential fire settings. Natl Inst Stand Technol, Tech. Note 1455-1

  2. Bukowski RW, Waterman TE, Christian WJ (1975) Detector sensitivity and siting requirements for dwellings: Report of the NBS Indiana Dunes Tests. No. SPP-43 Nat. Fire Prot. Assn., Quincy, MA

  3. Su JZ, Crampton GP, Carpenter DW, McCartney C, Leroux P (2003) Kemano fire studies—part 1: response of residential smoke alarms. Research Report 108, National Research Council of Canada, Ottawa, Canada

  4. BS 5852:2006 Methods of test for assessment of the ignitability of upholstered seating by smouldering and flaming ignition sources, British Standards Institute

  5. NFPA 72, National Fire Alarm Code (2007) 2007 Edition, National Fire Protection Association, Quincy, MA

Download references

Acknowledgements

The author would like to acknowledge James Filliben of the NIST Statistical Engineering Division for helpful discussions about experimental design. Michael Selepak, Laurean Delauter, Doris Rhinehart, Greg Masenheimer, and Anthony Chakalis supported the research through construction of the test structure, instrumentation set up and running the tests. Matthew Bundy, manager of the Large Fire Laboratory, was helpful keeping the tight test schedule on time and in assuring safe operation of the tests.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Thomas Cleary.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Cleary, T. Results from a Full-Scale Smoke Alarm Sensitivity Study. Fire Technol 50, 775–790 (2014). https://doi.org/10.1007/s10694-010-0152-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10694-010-0152-2

Keywords

Navigation