Abstract
Cellulose nitrate membrane filter was used for the preconcentration-separation of Cu, Co, Cd, Pb and Cr ions. The analyte ions were collected on the membrane filter by the aid of carmine. Then membrane filter was dissolved by using nitric acid. The levels of the analytes in the final solutions were determined by flame atomic absorption spectrometry (FAAS). The analytical parameters including pH, amounts of carmine, sample volumes etc. have been optimized. No influences have been observed from the matrix ions. The detection limits for analytes were in the range of 0.08 μg/l-0.93 μg/l. The validation of the procedure was checked by the analysis of standard reference sediment (GBW 07309). The present method has been successfully applied for the FAAS determinations of analyte ions in real samples including black tea and magnesium salts.
Similar content being viewed by others
References
Afzali, D., Taher, M.A., Mostafavi, A., & Mahani, M.K. (2005). Flame atomic absorption spectrometric determination of trace amounts of nickel after extraction and preconcentration onto natural modified analcime zeolite loaded with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol. Journal of AOAC International, 88, 842– 846.
Anderson, S.S., dos Santos, W.N.L., Ferreira, S.L.C. (2005). Application of Box-Behnken design in the optimisation of an on-line pre-concentration system using knotted reactor for cadmium determination by flame atomic absorption spectrometry. Spectrochimica Acta, 60B, 737– 742.
Bahramifar, N., & Yamini, Y. (2005). On-line preconcentration of some rare earth elements in water samples using C18-cartridge modified with l-(2-pyridylazo) 2-naphtol (PAN) prior to simultaneous determination by inductively coupled plasma optical emission spectrometry (ICP-OES). Analytica Chimica Acta, 540, 325– 332.
Bispo, M.S., da Boa Morte, E.S., Korn, M.G.A., Teixeira, L.S.G., Korn, M., & Costa, A.C.S. (2005). Determination of Pb in river water samples by inductively coupled plasma optical emission spectrometry after ultrasound-assisted co-precipitation with manganese dioxide. Spectrochimica Acta, 60B, 653– 658.
Cassella, R.J., Bitencourt, D.T., Branco, A.G., Ferreira, S.L.C., De Jesus, D.S., De Carvalho, M.S., & Santelli, R.E. (1999). Online preconcentration system for flame atomic absorption spectrometry using unloaded polyurethane foam: determination of zinc in waters and biological materials. Journal of Analytical Atomic Spectrometry, 14 1749– 1753.
Cerutti, S., Salonia, J.A., Ferreira, S.L.C., Olsina, R.A., & Martinez, L.D. (2004). Factorial design for multivariate optimization of an on-line preconcentration system for platinum determination by ultrasonic nebulization coupled to inductively coupled plasma optical emission spectrometry. Talanta, 63, 1077– 1082.
Cheng, Q., & Dong, H. (2005). Solvent Sublation Using Dithizone as a Ligand for Determination of Trace Elements in Water Samples. Microchimica Acta, 150 59– 65.
Cpara, C., Hasegawa, S., & Naito, K. (2003). Collection of Iron(III) from Homogeneous Aqueous Solutions on Membrane Filters Using Chromazurol B with Triton X-100. Analytical Sciences, 19, 265– 268.
dos Santos, E.J., Herrmann, A.B., Ribeiro, A.S., & Curtius, A.J. (2005). Determination of Cd in biological samples by flame AAS following on-line preconcentration by complexation with O,O-diethyldithiophosphate and solid phase extraction with Amberlite XAD-4. Talanta, 65, 593– 597.
Duan, T., Song, X., Jin, D., Li, H., Xu, J., & Chen, H. (2005). Preliminary results on the determination of ultratrace amounts of cadmium in tea samples using a flow injection on-line solid phase extraction separation and preconcentration technique to couple with a sequential injection hydride generation atomic fluorescence spectrometry. Talanta, 67, 968– 974.
Erdem, A., & Eroglu, A.E. (2005). Speciation and preconcentration of inorganic antimony in waters by Duolite GT-73 microcolumn and determination by segmented flow injection-hydride generation atomic absorption spectrometry (SFI-HGAAS). Talanta, 68, 86– 92.
Farias, G.M., Moyano, S., Gasquez, J.A., Wuilloud, R., & Martinez, L.D. (2002). Determination of cobalt by ICP-AES in drinking water samples using a knotted reactor with flow-injection on-line. Journal of the Argentine Chemical Society, 90, 77– 90.
Ferreira, S.L.C., De Jesus, D.S., Cassella, R.J., Costa, A.C.S., De Carvalho, M.S., & Santelli, R.E. (1999). An on-line solid phase extraction system using polyurethane foam for the spectrophotometric determination of nickel in silicates and alloys. Analytica Chimica Acta, 378, 287– 292.
Ferreira, S.L.C., Dos Santos, W. N.L., & Lemos, V.A. (2001). On-line preconcentration system for nickel determination in food samples by flame atomic absorption spectrometry. Analytica Chimica Acta, 445, 145– 151.
Ferreira, S.L.C., Dos Santos, W.N.L., Bezerra, M.A., Lemos, V.A., & Bosque Sendra, J.M. (2003). Use of factorial design and Doehlert matrix for multivariate optimisation of an on-line preconcentration system for lead determination by flame atomic absorption spectrometry. Analytical and Bioanalytical Chemistry, 375, 443– 449.
Gao, P.Y., Gu, X.X., & Zhou, T.Z. (1996). New Separation Method for Chromium(VI) in Water by Collection of its Ternary Complex on an Organic Solvent-Soluble Membrane Filter. Analytica Chimica Acta, 332, 307– 312.
Gama, E.M., Lima, A.S., & Lemos, V.A. (2006). Preconcentration system for cadmium and lead determination in environmental samples using polyurethane foam/Me-BTANC. Journal of Hazardous Materials, in press. enlargethispage-12pt
Ghaedi, M., Ahmadi, F., Karimi, H., & Gharaghani, S. (2006). Preconcentration and extraction of copper on activated carbon using 4-Amino-2, 3-dimethyl-1-phenyl-3-pyrazoline or 4-(4-methoxybenzylidenimin) thiophenole. Journal of the Korean Chemical Society, 50, 23– 31.
Itoh, J., Komata, M., Fijiyoshi, N., & Tsushima, H. (1983). Pre-Concentration of Trace Cobalt on Solvent-Soluble Membrane Filter Using Nitroso-R and Its Application for Graphite Furnace Atomic Absorption Spectrometry. Nippon Kagaku Kaishi, 6, 715– 718.
Jakmunkee, J., Sooksamiti, P., Geckies, H., & Grudpan, K. (2001). Flow Injection Sample Pretreatment for Determination of Lead by Flame Atomic Absorption Spectrophotometry. Analytical Sciences 17s, i1415– i1418.
Krishna, P.G., Rao, K.S., Biju, V.M., Rao, T.P., & Naidu, G.R.K. (2004), Simultaneous preconcentration of Cu, Cd and Pb from soil samples by solid phase extraction and their determination by flame AAS. Chemia Analityczna, 49, 383– 393.
Lemos, V.A., Santelli, R.E., De Carvalho, M.S., & Ferreira, S.L.C. (2000). Application of polyurethane foam loaded with BTAC in an on-line preconcentration system: cadmium determination by FAAS. Spectrochimica Acta B, 55, 1497– 1502.
Lemos, V.A., de Jesus, A.A., Gama, E.M., David, G.T., & Yamaki, R.T. (2005a). On-Line Solid Phase Extraction and Determination of Copper in Food Samples Using Polyurethane Foam Loaded with Me-BTANC. Analytical Letters, 38, 683– 696.
Lemos, V.A., & Baliza, P.X. (2005b). Amberlite XAD-2 functionalized with 2-aminothiophenol as a new sorbent for on-line preconcentration of cadmium and copper. Talanta, 67, 564– 570
Li, Z., Yuling, Y., Wei, Q., Liu, Z., & Tang, J. (2004), Fluorescence quenching method for determination of trace tungsten in environmental samples with dibromohydroxy-phenylfluorone. International Journal of Environmental Analytical Chemistry, 84, 789– 798.
Maitani, T, Xing, D.R., Ikeda, C.M., Goda, Y., Takeda, M., & Yoshihira, K. (1994). Application of ICP atomic-emission spectrometry with ultrasonic nebulizer to screening for carmine - determination of aluminum in canned cherries. Journal of the Food Hygienics Society of Japan, 35, 201– 205.
Marchisio, P.F., Sales, A., Cerutti, S., Marchevski, E., & Mar-tinez, L.D. (2005). On-Line Preconcentration/Determina-tion Of Lead Ylex Paraguariensis Samples (Mate Tea) Using Polyurethane Foam as Filter and USN-ICP-OES. Journal of Hazardous Materials, 124, 113– 118.
Matos, G.D., Tarley, C.R.T., Ferreira, S.L.C., & Arruda, M.A.Z. (2005). Use of experimental design in the optimisation of a solid phase preconcentration system for Cobalt determination by GFAAS. Ecletica Quimica, 30, 65– 74.
Mostafavi, A., Taher, M.A., Afzali, D., Mohammadi, S.Z., & Pour, A.S. (2005). Modified Bentonite as A New Sorbent For Separation and Preconcentration Trace Amounts of Metal Cations, The Fourth Jordanian International Conference of Chemistry, 19-21 Sept., Irbid-Jordan.
Narin, I., & Soylak, M. 2003. Enrichment and Determinations of Nickel(II), Cadmium(II), Copper(II), Cobalt(II) and Lead(II) Ions in Natural Waters, Table Salts, Tea and Urine Samples as Pyrrolydine Dithiocarbamate Chelates by Membrane Filtration-Flame Atomic Absorption Spectrometry Combination. Analytica Chimica Acta, 493, 205– 212.
Pourreza, N., & Ghanemi, K. 2006. Determination of copper by flame atomic absorption spectrometry after solid-phase extraction. Spectroscopy Letters, 39, 127– 134.
Praveen, R.S., Daniel, S., & Rao, T.P. (2005). Solid phase extraction preconcentration of cobalt and nickel with 5,7-dichloroquinone-8-ol embedded styrene-ethylene glycol dimethacrylate polymer particles and determination by flame atomic absorption spectrometry (FAAS). Talanta, 66, 513– 520.
Sakai, T., Suzui, M., Higuchi, H., Kajita, Y., & Uchida, T. (1997). Preconcentration on Organic Solvent-Soluble Membrane Filter and Spectrophotometric Determination of Trace Cobalt in Biological Samples. Analytical Sciences, 13S, 131– 136.
Seckin, T., & Koytepe, S. (2005). Preparation and characterization of novel polyimides from 2,6-bis[1-(p-dimethylaminophenylimino)ethyl] pyridine for the selective extraction of some metals. Polymer Bulletin, 55, 41– 49.
Soylak, M. (1998). Determination of Trace Amounts of Copper in Metallic Aluminium Samples after Separation and Preconcentration on an Activated Carbon Column. Fresenius Environmental Bulletin, 7, 383– 387.
Soylak, M., Divrikli, U., Elci, L., & Dogan, M. (2002). Preconcentration of Cr(III), Co(II), Cu(II), Fe(III) and Pb(II) as Calmagite Chelates on Cellulose Nitrate Membrane Filter Prior to their Flame Atomic Absorption Spectrometric Determinations. Talanta, 56, 565– 570.
Soylak, M., Karatepe, A.U., Elci, L., & Dogan, M. (2003). Column Preconcentration/Separation and Atomic Absorption Spectrometric Determinations of Some Heavy Metals in Table Salt Samples Using Amberlite XAD-1180, Turkish Journal of Chemistry, 27 (2003) 235– 242.
Soylak, M., Erdogan, N.D., & Elci, L. (2004). Membrane Filtration of Fe(III), Cu(II) and Pb(II) Ions as 1-(2-Pyridylazo) 2-Naphtol (PAN) for their Preconcentration and Atomic Absorption Determinations. Journal of the Chinese Chemical Society, 51, 703– 706.
Soylak, M., Narin, I., Bezerra, M.A., & Ferreira, S.L.C. (2005). Factorial Design in the Optimization of Preconcentration Procedure for Lead Determination by FAAS. Talanta, 65, 895– 899.
Suvardhan, K., Kumar, K.S., Reddy, K.M., Jyothi, M.V., & Chiranjeevi, P. (2004). Determination of trace metals with newly synthesized coniine dithiocarbamate by atomic absorption spectroscopy (AAS). E-Journal of Chemistry, 1, 99– 104.
Tuzen, M., Soylak, M., & Elci, L. (2005). Multi-element pre-concentration of heavy metal ions by solid phase extraction on Chromosorb 108. Analytica Chimica Acta, 548, 101– 108.
Wang, L.Q., Li, J.Q., & Deng, Y.L. (2001). Determination of trace nickel in coal gangue by catalytic fading spectrophotometry. Spectroscopy and Spectral Analysis, 21, 731– 732.
Ying, T., Li, Z.J., Juan, Z., & Pan, J.M. (2005). Recent advances of the derivatives of pyridylazo as reagents in analytical chemistry. Reviews In Analytical Chemistry, 24, 103– 147.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Soylak, M., Divrikli, U., Saracoglu, S. et al. Membrane filtration – atomic absorption spectrometry combination for copper, cobalt, cadmium, lead and chromium in environmental samples. Environ Monit Assess 127, 169–176 (2007). https://doi.org/10.1007/s10661-006-9271-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10661-006-9271-0