Skip to main content
Log in

Indoor Air Quality at Salarjung Museum, Hyderabad, India

  • Published:
Environmental Monitoring and Assessment Aims and scope Submit manuscript

Abstract

Deterioration of art objects at Salarjung Museum has been noticed such as blackening of white and pink pigments of Indian miniature paintings and other objects like pigments, paints, varnishes, coatings, silver ware, zari works, textiles, which are displayed in museum galleries. The cause of deterioration of the artifacts is attributed to air pollution. The outdoor air pollution levels with respect to suspended particulate matter, sulphur dioxide, oxides of nitrogen, ammonia, aldehydes and oxidants are observed to be high when compared with background environment and ambient air quality standards for sensitive areas. The indoor air quality levels in terms of various parameters including temperature and relative humidity (RH) observed to be more than the threshold limits. The climatic conditions coupled with polluted indoor air are the main causes for the deterioration of art objects. Hence remedial measures are suggested to avoid further deterioration of objects.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Central Pollution Control Board (CPCB): 1994, National Ambient Air Quality Standards (National), India.

  • Curatorial Care of Metal Objects, Extracted from the NPS Museum HandBook.

  • Glen, R. C., William, W. N., Christine, T. and Paul, M. W.: 1991, ‘Protection of works of art from damage due to atmospheric ozone’, Environment 25A(2), 441–450.

    Google Scholar 

  • James, P. L.: 1988, Methods of Air Sampling and Analysis, 3rd ed., Intersociety Committee, Lewis Publishers, Inc., pp. 403–492, U.S.A.

    Google Scholar 

  • Jean, T.: 1994, Display Materials: The Good, the Bad and the Ugly, Canadian Conservation Institute, Ottawa, Canada, ISBN 0950-8068-70, pp. 79–87.

    Google Scholar 

  • Jean, T.: 2000, Standards for Levels of Indoor Pollutants in Museums, Indoor Air Quality in Museums and Archives, Canadian Conservation Institute, April 25th, 2000.

  • Jean, T.: 1999, Standards for Levels of Pollutants in Museums: Part-II, IAP 1999, Presentation 5, Canadian Conservation Institute.

  • Katz, M.: 1977, Methods of Air Sampling and Analysis. Intersociety Committee Publication (2nd edn.), American Public Health Association, Washington DC, U.S.A.

    Google Scholar 

  • Moraueska, L., Bofingeo, N. D. and Marni, M.: 1995, Indoor Air an Integrated Approach, EPA Report U.S. 1995.

  • Raychaudhuri, M.: 1999, Formaldehyde Collection and Detection, IAP, Presentation 2, University of East Anglia.

  • Scottish Museums Council: 1994, Fact sheetThe Effect of Storage and Display Materials on Museum Objects, Scottish Museums Council, 1994.

  • WHO: 1976, ‘Selected methods for measuring air pollutants’, WHO collaborating center on air pollution control with US EPA, Washington DC, pp. 1–31.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. K. Reddy.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Reddy, M.K., Suneela, M., Sumathi, M. et al. Indoor Air Quality at Salarjung Museum, Hyderabad, India. Environ Monit Assess 105, 359–367 (2005). https://doi.org/10.1007/s10661-005-4344-z

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10661-005-4344-z

Keywords

Navigation