Skip to main content
Log in

Supplementation of organ culture medium with dextran is not required in pre-stripped human donor tissue for DMEK surgery

  • Published:
Cell and Tissue Banking Aims and scope Submit manuscript

Abstract

To assess corneal endothelial cell (CEC) quantity and quality in eye-bank prepared lamellar grafts for Descemet Membrane Endothelial Keratoplasty (DMEK) from organ cultured donor corneas that have not undergone de-swelling by media supplementation with dextran. Prior to graft preparation, corneas that had not undergone de-swelling (n = 30) were placed into fresh storage medium without dextran (KMI). Corneas in the control group (n = 30) were placed in dehydration medium containing 5% dextran (KMII). Subtotal stripping of Descemet’s membrane (DM) was performed manually. Following graft preparation, 10 corneas of each group were cultured further in their respective medium for 24 h, 72 h, or 120 h, respectively. Before and after DM stripping, as well as at the end of culture, CEC numbers were obtained. At the end of culture, CEC morphology was graded using a scoring system and CEC metabolism was assessed by detection of adenosine triphosphate. At 24 h after DM stripping, mean CEC counts (in cells/mm2) were 2204 in corneas stored in KMII, and 2391 in corneas stored in KMI (p = 0.003). This corresponds to a mean relative CEC loss of 12.4% with dextran versus 9.7% without dextran (p = 0.04). At 72 h, CEC counts were 1946 in KMII, and 2289 in KMI (p = 0.004). This corresponds to CEC loss of 23% with dextran versus 14% without dextran (p = 0.009). At 120 h, CEC counts were 2047 in KMII, and 2230 in KMI (p = 0.14). This corresponds to CEC loss of 22.7% with dextran versus 17.2% without dextran (p = 0.14). Also, at 120 h after DM stripping, 6/10 corneas fell below a threshold of 2000 cells/mm2 if stored in medium containing dextran, versus 1/9 corneas if stored without dextran (p = 0.003). Morphological assessment of CEC quality revealed equal scores for cell polymorphism (median = 1), granulation (median = 0) and segmentation (median = 1) in all groups. Lower ATP/protein ratios were observed in corneas stored in medium without dextran at 24 h (p < 0.001), 72 h (p < 0.001), and 120 h (p = 0.02). Abandoning the use of dextran in corneas destined for DMEK surgery leads to increased CEC counts and thereby serves to reduce tissue loss.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  • Abdin A, Daas L, Pattmöller M, Suffo S, Langenbucher A, Seitz S (2018) Negative impact of dextran in organ culture media for pre-stripped tissue preservation on DMEK (Descemet membrane endothelial keratoplasty) outcome. Graefes Arch Clin Exp Ophthalmol 256:2135–2142

    Article  CAS  PubMed  Google Scholar 

  • Armitage WJ, Easty DL (1997) Factors influencing the suitability of organ-cultured corneas for transplantation. Invest Ophthalmol Vis Sci 38:16–24

    CAS  PubMed  Google Scholar 

  • Bhogal M, Matter K, Balda MS, Allan B (2016) Organ culture storage of pre-prepared corneal donor material for Descemet’s membrane endothelial keratoplasty. Br J Ophthalmol 100:1576–1583

    Article  PubMed  PubMed Central  Google Scholar 

  • Borderie VM, Baudrimont M, Lopez M et al (1997) Evaluation of the deswelling period in dextran-containing medium after corneal organ culture. Cornea 16:215–223

    CAS  PubMed  Google Scholar 

  • Borderie VM, Scheer S, Touzeau O et al (1998) Donor organ cultured corneal tissue selection before penetrating keratoplasty. Br J Ophthalmol 82:382–388

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  • Bundesärztekammer (2018) Richtlinien zum Führen einer Hornhautbank. Dtsch Arztebl 115:262

    Google Scholar 

  • Heinzelmann S, Böhringer D, Eberwein P et al (2017) Graft dislocation and graft failure following Descemet membrane endothelial keratoplasty (DMEK) using precut tissue: a retrospective cohort study. Graefes Arch Clin Exp Ophthalmol 255:127–133

    Article  PubMed  Google Scholar 

  • Hermel M, Salla S, Fuest M, Walter P (2016) The role of corneal endothelial morphology in graft assessment and prediction of endothelial cell loss during organ culture of human donor corneas. Acta Ophthalmol 95:205–210

    Article  PubMed  Google Scholar 

  • Kruse FE, Schrehardt US, Tourtas T (2014) Optimizing outcomes with Descemet’s membrane endothelial keratoplasty. Curr Opin Ophthalmol 25:325–334

    Article  PubMed  Google Scholar 

  • Menzel-Severing J, Kruse FE, Tourtas T (2017) Organ-cultured, prestripped donor tissue for DMEK surgery: clinical outcomes. Br J Ophthalmol 101:1124–1127

    Article  PubMed  Google Scholar 

  • Nakagawa H, Inatomi T, Hieda O et al (2014) Clinical outcomes in Descemet stripping automated endothelial keratoplasty with internationally shipped precut donor corneas. Am J Ophthalmol 157:50–55.e1

    Article  PubMed  Google Scholar 

  • Palioura S, Colby K (2017) Outcomes of Descemet stripping endothelial keratoplasty using eye bank-prepared preloaded grafts. Cornea 36:21–25

    Article  PubMed  Google Scholar 

  • Parekh M, Ruzza A, Ferrari S, Ponzin D (2016) Preservation of preloaded DMEK lenticules in dextran and non-dextran-based organ culture medium. J Ophthalmol 2016:5830835

    PubMed  PubMed Central  Google Scholar 

  • Petty RD, Sutherland LA, Hunter EM, Cree IA (1995) Comparison of MTT and ATP-based assays for the measurement of viable cell number. J Biolumin Chemilumin 10:29–34

    Article  CAS  PubMed  Google Scholar 

  • Ragunathan S, Ivarsen A, Nielsen K, Hjortdal J (2014) Comparison of organ cultured precut corneas versus surgeon-cut corneas for Descemet’s stripping automated endothelial keratoplasty. Cell Tissue Bank 15:573–578

    Article  PubMed  Google Scholar 

  • Redbrake C, Salla S, Nilius R et al (1997) A histochemical study of the distribution of dextran 500 in human corneas during organ culture. Curr Eye Res 16:405–411

    Article  CAS  PubMed  Google Scholar 

  • Romano V, Parekh M, Ruzza A et al (2018) Comparison of preservation and transportation protocols for preloaded Descemet membrane endothelial keratoplasty. Br J Ophthalmol 102:549–555

    PubMed  Google Scholar 

  • Salla S, Redbrake C, Becker J, Reim M (1995) Remarks on the vitality of the human cornea after organ culture. Cornea 14:502–508

    Article  CAS  PubMed  Google Scholar 

  • Schlögl A, Tourtas T, Kruse FE, Weller JM (2016) Long-term clinical outcome after Descemet membrane endothelial keratoplasty. Am J Ophthalmol 169:218–226

    Article  PubMed  Google Scholar 

  • Yoeruek E, Hofmann J, Bartz-Schmidt KU (2013) Comparison of swollen and dextran deswollen organ-cultured corneas for Descemet membrane dissection preparation: histological and ultrastructural findings. Invest Ophthalmol Vis Sci 54:8036–8040

    Article  PubMed  Google Scholar 

  • Zhu L, Zha Y, Cai J, Zhang Y (2018) Descemet stripping automated endothelial keratoplasty versus descemet membrane endothelial keratoplasty: a meta-analysis. Int Ophthalmol 38:897–905

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Johannes Menzel-Severing.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

This article does not contain any studies with human participants or animals performed by any of the authors. However, this article does contain studies using human tissue. Informed consent was obtained from the relatives of all post-mortem tissue donors included in the study. All study procedures were performed in accordance with the principles laid down in the Declaration of Helsinki.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Salla, S., Kruse, F.E., Walter, P. et al. Supplementation of organ culture medium with dextran is not required in pre-stripped human donor tissue for DMEK surgery. Cell Tissue Bank 20, 193–200 (2019). https://doi.org/10.1007/s10561-019-09757-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10561-019-09757-8

Keywords

Navigation