Effect of freeze-drying and gamma irradiation on biomechanical properties of bovine pericardium

  • Y.M. Hafeez
  • A.B.Z. Zuki
  • N. Yusof
  • H. Asnah
  • M.Y. Loqman
  • M.M. Noordin
  • M.Y. Ainul-Yuzairi
Article

Abstract

Freeze-drying and gamma irradiation are the techniques widely use in tissue banking for preservation and sterilization of tissue grafts respectively. However, the effect of these techniques on biomechanical properties of bovine pericardium is poorly known. A total of 300 strips of bovine pericardium each measured 4 cm × 1 cm were used in this study to evaluate the effect of freeze-drying on biomechanical properties of fresh bovine pericardium and the effect of gamma irradiation on biomechanical properties of freeze-dried bovine pericardium. The strips were divided into three equal groups, which consist of 100 strips each group. The three groups were fresh bovine pericardium, freeze-dried bovine pericardium and irradiated freeze-dried bovine pericardium. The biomechanical properties of the pericardial strips were measured by a computer controlled instron tensiometer while the strips thickness was measured by Mitutoyo thickness gauge. The results of the study revealed that freeze-drying has no significant (p > 0.05) effect on the tensile strength, Young’s modulus (stiffness) and elongation rate of fresh bovine pericardium. Irradiation with 25 kGy gamma rays caused significant decreased in the tensile strength, Young’s modulus and elongation rate of the freeze-dried pericardium. However, gamma irradiation has no significant effect on the thickness of freeze-dried bovine pericardium, while freeze-drying caused significant decreased in the thickness of the fresh bovine pericardium. The outcome of this study demonstrated that freeze-drying has no significant effect on the biomechanical properties of fresh bovine pericardium, and gamma irradiation caused significant effect on the biomechanical properties of freeze-dried bovine pericardium.

Keywords

Biomechanical properties Freeze-dried bovine pericardium Gamma irradiation 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Akira, M., Shuji, H., Norinao, M., Norimasa, N., Tatsuo, M., Konsei, S. 1998Solvent dried and gamma-irradiated tendon allografts in rats, mechanical and morphological valuationJ. Bone Surg.80-B731736Google Scholar
  2. Alain, C., David, E.P., Ashley, W. 1997Freeze drying of cardiac valves in preparation for cellular repopulationCryobiology341322CrossRefPubMedGoogle Scholar
  3. Anson, J.A., Marchand, E.P. 1996Bovine pericardium for dural grafts: clinical results in 35 patientsNeurosurgery39764768CrossRefPubMedGoogle Scholar
  4. Balderson, D.S., Currey, J.D., Pegg, D.E. 1988The effect of freeze-drying on the mechanical properties of bone destined for alloimplantation11th Conference of the ESB July 8–11ToulouseFranceGoogle Scholar
  5. Brasile, D.M., Soares, M.J., Souza, D.R., Ramirez, V.D., Suzigan, S., Godoy, M.F. 1998Mapping of bovine pericardium physical and histological testsJ. Heart Valve Dis.7202206PubMedGoogle Scholar
  6. Cornu, O., Banse, X., Docquire, P.L., Luyckx, S., Delloye, C.H. 2000Effect of freeze-drying and gamma irradiation on the mechanical properties of human cancellous boneJ. Orthop. Res.18426430CrossRefPubMedGoogle Scholar
  7. Crofts, C.E., Trowbridge, E.A. 1998The tensile strength of natural and chemically modified bovine pericardiumJ. Biomed. Mater. Res.228998CrossRefGoogle Scholar
  8. Dorpema, J.W. 1990Review and state of the art on radiation sterilization of medical devicesRadiat. Phys. Chem.35357360Google Scholar
  9. Dwight, A.W., Frederick, W.W. 1983Mechanical and functional properties of implanted freeze-dried flexor tendonsClin. Orthop.180301309PubMedGoogle Scholar
  10. Flanks, F. 1998Freeze-drying of byproducts putting principles into practiceEur. J. Pharm. Biopharm.45221229CrossRefPubMedGoogle Scholar
  11. Fengmei, L.I., Chen, D 1998Effect of radiation on structure and properties of materials made from ox pericardiumRadiat. Phys. Chem.52323326CrossRefGoogle Scholar
  12. James, N.L., Poole-Warren, L.A., Schindhlem, B.K., Mitchell, R.M., Mitchell, R.E., Howlett, C.R.. 1991Comparative evaluation of treated bovine pericardium as a xenograft for hernia repairBiomaterial12801809CrossRefGoogle Scholar
  13. Jai, Raman, John, C.H. 1990Freeze-dried micro arterial allograftsPlast. Reconstr. Surg.85248251PubMedGoogle Scholar
  14. Jose, M., Garcia, P., Eduardo, J.H., Antonio, C., Isabel, M.A., Aurora, R.P. 2001Ostrich pericardiuma biomaterial for construction of valve leafletsBiomaterials2227312740CrossRefPubMedGoogle Scholar
  15. Klinge, U., Conze, J., Limberg, W., Brucker, C., Ottinger, A.P., Schum-Pelick, V. 1996Pathophysiology of the abdominal wallChirurg67229233PubMedGoogle Scholar
  16. Langon, S.E., Chernecky, R., Pereira, C.A., Abdulla, D., Lee, J.M. 1999Biaxial mechanical/structural effects of equibiaxial strain during crosslinking of bovine pericardial xenograft materialsBiomaterials20137153CrossRefPubMedGoogle Scholar
  17. Maeda, A., Inoue, M., Shino, K., Nakata, K., Nakamura, H., Tanaka, M., Seguchi, Y., Ono, K. 1993Effects of solvent preservation with or without gamma irradiation on the material properties of canine tendon allograftsJ. Orthop. Res.11181189CrossRefPubMedGoogle Scholar
  18. Michael, J.L., Derek, R.B. 1981Tissue mechanics of canine pericardium in different test environmentsCirc. Res.49533544PubMedGoogle Scholar
  19. Michael, J.L., Shari, E.L. 1996Thickness measurement of soft tissue biomaterials: A comparison of five methodsJ. Biomech.29829832CrossRefPubMedGoogle Scholar
  20. Moore, C.H., Martelli, V., AI-Janabi, N., Ross, D.N. 1975Analysis of homograft valve failure in 311 patients followed up to 10 yearsAnn. Thorac. Surg.20274281PubMedGoogle Scholar
  21. Richard, H., Riyaz, H.J., Cal, J., Karen, W., Hugh, J.C. 1992A biomechanical analysis of solvent dehydrated and freeze-dried human fascia lata allografts: a preliminary reportAm. J. Sports Med.20607612PubMedGoogle Scholar
  22. Roberto, S., Benson,  2002Use of radiation in biomaterials scienceNucl. Instrum. Meth. B191752757Google Scholar
  23. Sacks, M.S., Chuong, C.J., More, R. 1992Collagen fiber architecture of bovine pericardiumASAIO J.40632637Google Scholar
  24. Santillan, D.P., Jasso, V.R., Sotres-Vega, A., Olmos, R., Arreola, J.L., Garc-ia, D., Vanda, B., Gaxiola, M. 1995Repair of thoracoabdominal wall defects in dogs using a bovine pericardium bioprosthesisRev. invest. Clin.47439446PubMedGoogle Scholar
  25. Tokuhiro, I., Victor, J.F., Michael, J., Steven, W.B., Boyce, B.A., William, C.R. 1981Structure of bovine parietal pericardium and of un implanted Ionescu-Shiley pericardial valvular bioprosthesesJ. Thorac. Cardiovasc. Surg.81747757PubMedGoogle Scholar
  26. Trowbridge, E.A., Roberts, K.M., Lawford, P.V. 1986Pericardial heterografts towards quality control of mechanical properties of glutaraldehyde fixed leafletsJ. Thorac. Cardiovas. Surg.922128Google Scholar
  27. Won Kyu, L., Ki Dong, P., Dong Keun, H., Hwal, S., Jong-Chul, P., Young Ha, K. 2000Heparinized bovine pericardium as a novel cardiovascular bioprosthesisBiomaterials2123232330CrossRefPubMedGoogle Scholar
  28. Yukiyoshi, T., Konsei, S., Shuji, H., Norimasa, N. 1997Effect of freeze-drying or gamma irradiation on remodeling of tendon allograft in a rat modelJ. Orthop. Res.15294300CrossRefPubMedGoogle Scholar
  29. Zioupos, P., Barbenel, J.C. 1994Mechanics of native bovine pericardium II. A structure based model for the anisotropic mechanical behavior of the tissueBiomaterials15374382CrossRefPubMedGoogle Scholar

Copyright information

© Springer 2005

Authors and Affiliations

  • Y.M. Hafeez
    • 1
  • A.B.Z. Zuki
    • 2
  • N. Yusof
    • 3
  • H. Asnah
    • 3
  • M.Y. Loqman
    • 2
  • M.M. Noordin
    • 2
  • M.Y. Ainul-Yuzairi
    • 2
  1. 1.Faculty of Veterinary MedicineUniversity of KhartoumKhartoum NorthSudan
  2. 2.Faculty of Veterinary MedicineUniversiti Putra MalaysiaSerdangMalaysia
  3. 3.Malaysian Institute for Nuclear Technology Research (MINT) BangiKajangMalaysia

Personalised recommendations