Skip to main content

Advertisement

Log in

Influence of Oil Injection System on Efficiency of Speed-Controlled Screw Refrigeration Compressor

  • Published:
Chemical and Petroleum Engineering Aims and scope

The problems of enhancing the efficiency of screw refrigeration compressors with speed control of refrigeration output are studied. Based on a mathematical model developed, it is demonstrated that compressor efficiency depends a great deal on the operation of the oil injection system. When an oil injection system that ensures optimal compressor operation under fixed conditions is chosen, change in operation conditions does not cause significant loss of efficiency. At the same time, if the oil injection system is non-optimal, change in operation conditions does not enhance compressor efficiency. This means that the configuration of the oil injection system determines the level of compressor efficiency, which remains practically unchanged if the operation conditions are changed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. A. V. Baranenko, N. N. Bukharin, V. I. Pekarev, et al., Refrigerating Machines, Politekhnika, St. Petersburg (1987).

    Google Scholar 

  2. I. G. Khisameev and V. A. Maksimov, Twin Rotor Compressor: Theory, Calculation, and Designing, Fen, Kazan (2000).

    Google Scholar 

  3. I. A. Sakun, Screw Compressors, Mashinostroenie, Leningrad (1979).

    Google Scholar 

  4. D. Mosemann, S. Krienke, and S. Nowotny, “Improvements of refrigeration screw compressors of large capacity,” Proc. Int. Compressor Engineering Conf., Purdue, USA (1988), pp. 250–255.

  5. H. Wu, X. Peng, Z. Xing, and P. Shu, “Experimental study on P–V indicator diagrams of twin screw refrigeration compressor with economizer,” Appl. Therm. Eng., 24, 1491–1500 (2004).

    Article  Google Scholar 

  6. B. V. Smirnov, R. M. Miftakhov, Yu. V. Milyutin, et al., Patent No. 2509678 RF, IPC B63G 8/36, F25B 49/02, “Method of control of refrigerating machine of ship air conditioning system,” subm. 10.01.2012, publ. 03.20.2014.

  7. www.apic.ru/marketing/mr_kompressor_2014.

  8. N. Stosic, I. K. Smith, and F. Kovacevic, Screw Compressors: Mathematical Modelling and Performance Calculation, Springer (2005).

  9. B. Sangfors, “Computer simulation of effects from injection of different liquids in screw compressors,” Int. Compr. Eng. Conf., Purdue, USA (1998), Vol. 1, pp. 595–600.

  10. A. L. Vernyi, “Study and method of calculation of screw compressors,” Processes, Technology, and Control in Cryogenic Engineering: Proc. VNIIkriogenmash, Balashikha (1978), pp. 72–82.

  11. V. L. Yusha, Enhancing Efficiency and Safety of Operation of Screw Compressor with Gas-Liquid Working Medium: Dissert. Cand. Techn. Sci., Leningrad (1987).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. L. Yusha.

Additional information

Translated from Khimicheskoe i Neftegazovoe Mashinostroenie, No. 9, pp. 6–10, September, 2016.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yusha, V.L., Vasil’ev, V.K., Chernov, G.I. et al. Influence of Oil Injection System on Efficiency of Speed-Controlled Screw Refrigeration Compressor. Chem Petrol Eng 52, 590–596 (2017). https://doi.org/10.1007/s10556-017-0238-5

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10556-017-0238-5

Keywords

Navigation