Abstract
Reliability (repeatability or agreement) is assessed by different statistical tests including Pearson r or Spearman rho which is one of the common mistakes in reliability analysis. Pearson r or Spearman rho correlation coefficient only assesses the linearity between two continuous variables. Any shift in the regression line’s location or scale, which leads to non-reliability, cannot be detected by these correlation coefficients. In reliability analysis, the individual approach should be considered instead of the global average. To correctly assess the reliability (agreement), for continuous variables, either the Bland –Altman plot or Intra-class correlation coefficient (ICC) absolute measure should be applied.
Availability of data and materials
Not applicable
References
Orii M, Sone M, Osaki T, Kikuchi K, Sugawara T et al Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult population. Int J Cardiovasc Imaging. 2023 Jan 17. doi: https://doi.org/10.1007/s10554-023-02793-2. Epub ahead of print. PMID: 36648573
Sabour S (2015) Spinal instability neoplastic scale: methodologic issues to avoid misinterpretation. AJR Am J Roentgenol 204(4):W493
Sabour S (2015) Reliability of automatic vibratory equipment for ultrasonic strain measurement of the median nerve: common mistake. Ultrasound Med Biol 41(4):1119–1120
Sabour S (2014) Methodologic concerns in reliability of noncalcified coronary artery plaque burden quantification. AJR Am J Roentgenol 203(3):W343
Sabour S (2016) Reproducibility of semi-automatic coronary plaque quantification in coronary CT angiography with sub-msv radiation dose; common mistakes. J Cardiovasc Comput Tomogr 10(5):e21–e22
Sabour S (2015) Reproducibility of dynamic Scheimpflug-based pneumotonometer and its correlation with a dynamic bidirectional pneumotonometry device: methodological issues. Cornea 34(5):14–15
Sabour S (2016) Reliability of a new modified tear breakup time method: methodological and statistical issues. Graefes Arch Clin Exp Ophthalmol 254(3):595–596
Sabour S, Ghassemi F (2012) Accuracy, validity, and reliability of the infrared optical head tracker (IOHT). Invest Ophthalmol Vis Sci 53(8):4776
Sabour S (2015) Validity and reliability of the new Canadian Nutrition Screening Tool in the ‘real-world’ hospital setting: methodological issues. Eur J Clin Nutr 69(7):864
Sabour S (2014) Validity and reliability of the 13 C-methionine breath test for the detection of moderate hyperhomocysteinemia in mexican adults; statistical issues in validity and reliability analysis. Clin Chem Lab Med 52(12):295–296
Acknowledgements
Not applicable
Funding
None
Author information
Authors and Affiliations
Contributions
SS contributed effectively to: 1) Substantial contributions to the conception of the manuscript; 2) Drafting the article and revising it critically for important intellectual content; and 3) Final approval of the version to be published.
Corresponding author
Ethics declarations
Competing interests
The author declare that there are no competing interests.
Permissions
Not relevant.
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Conflict of interests
The author declares that there are no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Sabour, S., Torabi, A. Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult population; a common mistake. Int J Cardiovasc Imaging 39, 1203–1205 (2023). https://doi.org/10.1007/s10554-023-02821-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10554-023-02821-1