Reliability (repeatability or agreement) is assessed by different statistical tests including Pearson r or Spearman rho which is one of the common mistakes in reliability analysis. Pearson r or Spearman rho correlation coefficient only assesses the linearity between two continuous variables. Any shift in the regression line’s location or scale, which leads to non-reliability, cannot be detected by these correlation coefficients. In reliability analysis, the individual approach should be considered instead of the global average. To correctly assess the reliability (agreement), for continuous variables, either the Bland –Altman plot or Intra-class correlation coefficient (ICC) absolute measure should be applied.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Availability of data and materials

Not applicable

References

  1. Orii M, Sone M, Osaki T, Kikuchi K, Sugawara T et al Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult population. Int J Cardiovasc Imaging. 2023 Jan 17. doi: https://doi.org/10.1007/s10554-023-02793-2. Epub ahead of print. PMID: 36648573

  2. Sabour S (2015) Spinal instability neoplastic scale: methodologic issues to avoid misinterpretation. AJR Am J Roentgenol 204(4):W493

    Article  PubMed  Google Scholar 

  3. Sabour S (2015) Reliability of automatic vibratory equipment for ultrasonic strain measurement of the median nerve: common mistake. Ultrasound Med Biol 41(4):1119–1120

    Article  PubMed  Google Scholar 

  4. Sabour S (2014) Methodologic concerns in reliability of noncalcified coronary artery plaque burden quantification. AJR Am J Roentgenol 203(3):W343

    Article  PubMed  Google Scholar 

  5. Sabour S (2016) Reproducibility of semi-automatic coronary plaque quantification in coronary CT ‎angiography with sub-msv radiation dose; common mistakes. J Cardiovasc Comput ‎Tomogr 10(5):e21–e22

    Article  PubMed  Google Scholar 

  6. Sabour S (2015) Reproducibility of dynamic Scheimpflug-based pneumotonometer and its ‎correlation with a dynamic bidirectional pneumotonometry device: methodological issues. ‎Cornea 34(5):14–15

    Google Scholar 

  7. Sabour S (2016) Reliability of a new modified tear breakup time method: methodological and ‎statistical issues. Graefes Arch Clin Exp Ophthalmol 254(3):595–596

    Article  PubMed  Google Scholar 

  8. Sabour S, Ghassemi F (2012) Accuracy, validity, and reliability of the infrared optical head tracker (IOHT). Invest Ophthalmol Vis Sci 53(8):4776

    Article  PubMed  PubMed Central  Google Scholar 

  9. Sabour S (2015) Validity and reliability of the new Canadian Nutrition Screening Tool in the ‘real-world’ hospital setting: methodological issues. Eur J Clin Nutr 69(7):864

    Article  CAS  PubMed  Google Scholar 

  10. Sabour S (2014) Validity and reliability of the 13 C-methionine breath test for the detection of moderate hyperhomocysteinemia in mexican adults; statistical issues in validity and reliability analysis. Clin Chem Lab Med 52(12):295–296

    Google Scholar 

Download references

Acknowledgements

Not applicable

Funding

None

Author information

Authors and Affiliations

Authors

Contributions

SS contributed effectively to: 1) Substantial contributions to the conception of the manuscript; 2) Drafting the article and revising it critically for important intellectual content; and 3) Final approval of the version to be published.

Corresponding author

Correspondence to Siamak Sabour.

Ethics declarations

Competing interests

The author declare that there are no competing interests.

Permissions

Not relevant.

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Conflict of interests

The author declares that there are no competing interests.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sabour, S., Torabi, A. Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult population; a common mistake. Int J Cardiovasc Imaging 39, 1203–1205 (2023). https://doi.org/10.1007/s10554-023-02821-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-023-02821-1

Keywords

Navigation