Abstract

In myocardial gated SPECT imaging each cardiac cycle is divided into 8 or 16 temporal frames and the cause of the difference between 8 and 16 frames is not specified exactly. The aim of this study was to investigate the effect of myocardial detector counts and gender on the difference between 8 and 16 frames and also to compare the LVEF obtained by 8 and 16 frames with echocardiography. The study population included 84 patients who underwent gated SPECT imaging. Left ventricular parameters were assessed on 8 and 16 frames gated SPECT. LVEF was also measured with two-dimensional echocardiography within 5–10 days after gated SPECT imaging. There was a good correlation between 8 and 16 frames for calculation of LVEF (p = 0.00, r = 0.860), EDV (p = 0.00, r = 0.965) and ESV (p = 0.00, r = 0.956) in all patients. But the difference between 8 and 16 frames for calculation of LVEF (p = 0.00), EDV (p = 0.014) and ESV (p = 0.00) was statistically significant. This difference was assessed separately in females, males, patients with high photon counts and patients with low photon counts and in all subgroups was statistically significant difference in the estimation of LVEF and ESV (p < 0.05) but no significant difference in the estimation of EDV (p > 0.05). Echocardiography resulted in smaller LVEF as compared to 8 and 16 frames gated SPECT studies and there was a significant difference between the two methods (p = 0.00). The myocardial detector counts and gender have no effect on the difference between 8 and 16 frames methods and the LVEF on echocardiography is smaller than the gated SPECT, but the 8-frame is closer to echocardiography.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Go V, Bhatt MR, Hendel RC (2004) The diagnostic and prognostic value of ECG-gated SPECT myocardial perfusion imaging. J Nucl Med 45(5):912–921

    PubMed  Google Scholar 

  2. Paul AK, Nabi HA (2004) Gated myocardial perfusion SPECT: basic principles, technical aspects, and clinical applications. J Nucl Med Technol 32(4):179–187

    PubMed  Google Scholar 

  3. Kurisu S, Sumimoto Y, Ikenaga H, Watanabe N, Ishibashi K, Dohi Y, Fukuda Y, Kihara Y (2017) Comparison of 8-frame and 16-frame thallium-201 gated myocardial perfusion SPECT for determining left ventricular systolic and diastolic parameters. Heart Vessels 32(7):790–795. https://doi.org/10.1007/s00380-016-0935-6

    Article  PubMed  Google Scholar 

  4. Montelatici G, Sciagrà R, Passeri A, Dona M, Pupi A (2008) Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies. Eur J Nucl Med Mol Imaging 35(11):2059–2065. https://doi.org/10.1007/s00259-008-0866-2

    Article  PubMed  Google Scholar 

  5. Navare SM, Wackers FJ, Liu Y-H (2003) Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction. Eur J Nucl Med Mol Imaging 30(10):1330–1337. https://doi.org/10.1007/s00259-003-1231-0

    Article  PubMed  Google Scholar 

  6. Akincioglu C, Berman DS, Nishina H, Kavanagh PB, Slomka PJ, Abidov A, Hayes S, Friedman JD, Germano G (2005) Assessment of diastolic function using 16-frame 99mTc-sestamibi gated myocardial perfusion SPECT: normal values. J Nucl Med 46(7):1102–1108

  7. Ansari M, Hashemi H, Soltanshahi M, Qutbi M, Azizmohammadi Z, Tabeie F, Javadi H, Jafari E, Barekat M, Assadi M (2018) Factors that impact evaluation of left ventricular systolic parameters in myocardial perfusion gated SPECT with 16 frame and 8 frame acquisition models. Mol Imaging Radionuclide Therapy 27(2):55. https://doi.org/10.4274/mirt.49368

    Article  Google Scholar 

  8. Kumita S-i, Cho K, Nakajo H, Toba M, Uwamori M, Mizumura S, Kumazaki T, Sano J, Sakai S, Munakata K (2001) Assessment of left ventricular diastolic function with electrocardiography-gated myocardial perfusion SPECT: comparison with multigated equilibrium radionuclide angiography. J Nucl Cardiol 8(5):568–574. https://doi.org/10.1067/mnc.2001.116853

    Article  CAS  PubMed  Google Scholar 

  9. Wright GA, McDade M, Keeble W, Martin W, Hutton I (2001) Are ejection fractions from gated SPECT perfusion studies clinically useful? A comparison with radionuclide ventriculography. Physiol Meas 22(2):413. https://doi.org/10.1088/0967-3334/22/2/312

    Article  CAS  PubMed  Google Scholar 

  10. Hutyra M, Skala T, Kaminek M, Zapletalova J (2010) Comparison of left ventricular volumes and ejection fraction assessment by two-dimensional echocardiography compared with gated myocardial spect in patients with ischemic cardiomyopathy. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 154(1):47–54

    Article  Google Scholar 

  11. Nichols K, Lefkowitz D, Faber T, Folks R, Cooke D, Garcia EV, Yao S-S, DePuey EG, Rozanski A (2000) Echocardiographic validation of gated SPECT ventricular function measurements. J Nucl Med 41(8):1308–1314

    CAS  PubMed  Google Scholar 

  12. Shojaeifard M, Ghaedian T, Yaghoobi N, Malek H, Firoozabadi H, Bitarafan-Rajabi A, Haghjoo M, Amin A, Azizian N, Rastgou F (2016) Comparison of gated SPECT myocardial perfusion imaging with echocardiography for the measurement of left ventricular volumes and ejection fraction in patients with severe heart failure. Res Cardiovasc Med. https://doi.org/10.5812/cardiovascmed.29005

    Article  PubMed  PubMed Central  Google Scholar 

  13. Verberne HJ, Acampa W, Anagnostopoulos C, Ballinger J, Bengel F, De Bondt P, Buechel RR, Cuocolo A, van Eck-Smit BL, Flotats A (2015) EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision. Eur J Nucl Med Mol Imaging 42(12):1929–1940. https://doi.org/10.1007/s00259-015-3139-x

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  14. Ala’eldin AA, Sciacca RR, Kim B, Bergmann SR (2000) Normal limits for left ventricular ejection fraction and volumes estimated with gated myocardial perfusion imaging in patients with normal exercise test results: influence of tracer, gender, and acquisition camera. J Nucl Cardiol 7(6):661–668. https://doi.org/10.1067/mnc.2000.109861

    Article  Google Scholar 

  15. Vaduganathan P, He Z-X, Vick GW, Mahmarian JJ, Verani MS (1999) Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99 m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging. J Nucl Cardiol 6(1):3–10. https://doi.org/10.1016/S1071-3581(99)90058-2

    Article  CAS  PubMed  Google Scholar 

  16. Hovland A, Staub UH, Bjørnstad H, Prytz J, Sexton J, Støylen A, Vik-Mo H (2010) Gated SPECT offers improved interobserver agreement compared with echocardiography. Clin Nucl Med 35(12):927–930. https://doi.org/10.1097/rlu.0b013e3181f9ddfb

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

This study is a postgraduate thesis and was supported by Semnan university of medical science. We thank our colleagues at the Raaheaseman Center of Nuclear Medicine.

Funding

This work was supported by Semnan University of Medical Sciences, under grant number 1739.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mohammad Ali Tajik-Mansoury.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest. I certify that there is no actual or potential conflict of interest in relation to this article.

Ethical approval

All stages of this research have been reviewed by the ethics committee of Semnan University of Medical Sciences. Approval number is (IR.SEMUMS.REC.1398.186).

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Mazinani, M., Tajik-Mansoury, M.A., Sabour, M. et al. A comparison of 8 and 16 frames gated SPECT imaging for determination of left ventricular volumes and ejection fraction: effects of gender and myocardial counts. Int J Cardiovasc Imaging 37, 2079–2084 (2021). https://doi.org/10.1007/s10554-021-02170-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-021-02170-x

Keywords

Navigation