Abstract
In myocardial gated SPECT imaging each cardiac cycle is divided into 8 or 16 temporal frames and the cause of the difference between 8 and 16 frames is not specified exactly. The aim of this study was to investigate the effect of myocardial detector counts and gender on the difference between 8 and 16 frames and also to compare the LVEF obtained by 8 and 16 frames with echocardiography. The study population included 84 patients who underwent gated SPECT imaging. Left ventricular parameters were assessed on 8 and 16 frames gated SPECT. LVEF was also measured with two-dimensional echocardiography within 5–10 days after gated SPECT imaging. There was a good correlation between 8 and 16 frames for calculation of LVEF (p = 0.00, r = 0.860), EDV (p = 0.00, r = 0.965) and ESV (p = 0.00, r = 0.956) in all patients. But the difference between 8 and 16 frames for calculation of LVEF (p = 0.00), EDV (p = 0.014) and ESV (p = 0.00) was statistically significant. This difference was assessed separately in females, males, patients with high photon counts and patients with low photon counts and in all subgroups was statistically significant difference in the estimation of LVEF and ESV (p < 0.05) but no significant difference in the estimation of EDV (p > 0.05). Echocardiography resulted in smaller LVEF as compared to 8 and 16 frames gated SPECT studies and there was a significant difference between the two methods (p = 0.00). The myocardial detector counts and gender have no effect on the difference between 8 and 16 frames methods and the LVEF on echocardiography is smaller than the gated SPECT, but the 8-frame is closer to echocardiography.
Similar content being viewed by others
References
Go V, Bhatt MR, Hendel RC (2004) The diagnostic and prognostic value of ECG-gated SPECT myocardial perfusion imaging. J Nucl Med 45(5):912–921
Paul AK, Nabi HA (2004) Gated myocardial perfusion SPECT: basic principles, technical aspects, and clinical applications. J Nucl Med Technol 32(4):179–187
Kurisu S, Sumimoto Y, Ikenaga H, Watanabe N, Ishibashi K, Dohi Y, Fukuda Y, Kihara Y (2017) Comparison of 8-frame and 16-frame thallium-201 gated myocardial perfusion SPECT for determining left ventricular systolic and diastolic parameters. Heart Vessels 32(7):790–795. https://doi.org/10.1007/s00380-016-0935-6
Montelatici G, Sciagrà R, Passeri A, Dona M, Pupi A (2008) Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies. Eur J Nucl Med Mol Imaging 35(11):2059–2065. https://doi.org/10.1007/s00259-008-0866-2
Navare SM, Wackers FJ, Liu Y-H (2003) Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction. Eur J Nucl Med Mol Imaging 30(10):1330–1337. https://doi.org/10.1007/s00259-003-1231-0
Akincioglu C, Berman DS, Nishina H, Kavanagh PB, Slomka PJ, Abidov A, Hayes S, Friedman JD, Germano G (2005) Assessment of diastolic function using 16-frame 99mTc-sestamibi gated myocardial perfusion SPECT: normal values. J Nucl Med 46(7):1102–1108
Ansari M, Hashemi H, Soltanshahi M, Qutbi M, Azizmohammadi Z, Tabeie F, Javadi H, Jafari E, Barekat M, Assadi M (2018) Factors that impact evaluation of left ventricular systolic parameters in myocardial perfusion gated SPECT with 16 frame and 8 frame acquisition models. Mol Imaging Radionuclide Therapy 27(2):55. https://doi.org/10.4274/mirt.49368
Kumita S-i, Cho K, Nakajo H, Toba M, Uwamori M, Mizumura S, Kumazaki T, Sano J, Sakai S, Munakata K (2001) Assessment of left ventricular diastolic function with electrocardiography-gated myocardial perfusion SPECT: comparison with multigated equilibrium radionuclide angiography. J Nucl Cardiol 8(5):568–574. https://doi.org/10.1067/mnc.2001.116853
Wright GA, McDade M, Keeble W, Martin W, Hutton I (2001) Are ejection fractions from gated SPECT perfusion studies clinically useful? A comparison with radionuclide ventriculography. Physiol Meas 22(2):413. https://doi.org/10.1088/0967-3334/22/2/312
Hutyra M, Skala T, Kaminek M, Zapletalova J (2010) Comparison of left ventricular volumes and ejection fraction assessment by two-dimensional echocardiography compared with gated myocardial spect in patients with ischemic cardiomyopathy. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 154(1):47–54
Nichols K, Lefkowitz D, Faber T, Folks R, Cooke D, Garcia EV, Yao S-S, DePuey EG, Rozanski A (2000) Echocardiographic validation of gated SPECT ventricular function measurements. J Nucl Med 41(8):1308–1314
Shojaeifard M, Ghaedian T, Yaghoobi N, Malek H, Firoozabadi H, Bitarafan-Rajabi A, Haghjoo M, Amin A, Azizian N, Rastgou F (2016) Comparison of gated SPECT myocardial perfusion imaging with echocardiography for the measurement of left ventricular volumes and ejection fraction in patients with severe heart failure. Res Cardiovasc Med. https://doi.org/10.5812/cardiovascmed.29005
Verberne HJ, Acampa W, Anagnostopoulos C, Ballinger J, Bengel F, De Bondt P, Buechel RR, Cuocolo A, van Eck-Smit BL, Flotats A (2015) EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision. Eur J Nucl Med Mol Imaging 42(12):1929–1940. https://doi.org/10.1007/s00259-015-3139-x
Ala’eldin AA, Sciacca RR, Kim B, Bergmann SR (2000) Normal limits for left ventricular ejection fraction and volumes estimated with gated myocardial perfusion imaging in patients with normal exercise test results: influence of tracer, gender, and acquisition camera. J Nucl Cardiol 7(6):661–668. https://doi.org/10.1067/mnc.2000.109861
Vaduganathan P, He Z-X, Vick GW, Mahmarian JJ, Verani MS (1999) Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99 m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging. J Nucl Cardiol 6(1):3–10. https://doi.org/10.1016/S1071-3581(99)90058-2
Hovland A, Staub UH, Bjørnstad H, Prytz J, Sexton J, Støylen A, Vik-Mo H (2010) Gated SPECT offers improved interobserver agreement compared with echocardiography. Clin Nucl Med 35(12):927–930. https://doi.org/10.1097/rlu.0b013e3181f9ddfb
Acknowledgements
This study is a postgraduate thesis and was supported by Semnan university of medical science. We thank our colleagues at the Raaheaseman Center of Nuclear Medicine.
Funding
This work was supported by Semnan University of Medical Sciences, under grant number 1739.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest. I certify that there is no actual or potential conflict of interest in relation to this article.
Ethical approval
All stages of this research have been reviewed by the ethics committee of Semnan University of Medical Sciences. Approval number is (IR.SEMUMS.REC.1398.186).
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Mazinani, M., Tajik-Mansoury, M.A., Sabour, M. et al. A comparison of 8 and 16 frames gated SPECT imaging for determination of left ventricular volumes and ejection fraction: effects of gender and myocardial counts. Int J Cardiovasc Imaging 37, 2079–2084 (2021). https://doi.org/10.1007/s10554-021-02170-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10554-021-02170-x