Skip to main content
Log in

Accuracy of three-dimensional echocardiography in candidates for transcatheter aortic valve replacement

  • Original Paper
  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

The correct determination of aortic annulus dimensions is a crucial step to avoid complications in Transcatheter Aortic Valve Replacement (TAVR). Currently, the gold standard method for the evaluation of the aortic annulus is Multidetector Computed Tomography (MDCT), which is limited by the risk of contrast-induced nephropathy. Three-dimensional transesophageal echocardiography automated software (3DTEEa) have been used as an alternative in patients with contra-indications to MDCT. We aimed to evaluate the accuracy of 3DTEEa-derived aortic annulus dimensions; to assess the influence of calcification in the agreement between 3DTEEa and MDCT; and to determine reclassification in prosthesis size choice if 3DTEEa was the only imaging method. One hundred and seven consecutive patients referred for TAVR were studied. Aortic annulus dimensions were determined using MDCT and 3DTEE manual (3DTEEm) and automated measurements. Valve calcification was assessed with MDCT. Limits of agreement (LOA) were narrower for 3DTEEa (minimum diameter: mean bias 0.60; LOA − 2.94 to 4.14; maximum diameter: mean bias 0.20; LOA − 3.82 to 4.22) as compared to 3DTEEm (minimum diameter: mean bias 0.22; LOA − 3.84 to 4.28; maximum diameter: mean bias − 1.25; LOA − 6.37; 3.86). Compared to MDCT, 3DTEEa overestimated while 3DTEEm underestimated most parameters. No differences were found in average bias between methods according to quartiles of valve calcification. Most patients would have received the same size valve (63.9%) if 3DTEEa was the only available method. Measurement of aortic annulus dimensions using a 3DTEE automatic software is feasible and not influenced by valve calcification. It may be an alternative for patients who cannot undergo MDCT.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Iung B, Baron G, Butchart EG, Delahaye F, Gohlke-Bärwolf C, Levang OW, Tornos P, Vanoverschelde J-L, Vermeer F, Boersma E (2003) A prospective survey of patients with valvular heart disease in Europe: the Euro heart survey on valvular heart disease. Eur Heart J 24(13):1231–1243

    Article  Google Scholar 

  2. Baumgartner H, Falk V, Bax JJ, De Bonis M, Hamm C, Holm PJ, Iung B, Lancellotti P, Lansac E, Rodriguez Munoz D (2017) 2017 ESC/EACTS guidelines for the management of valvular heart disease The Task Force for the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J 38(36):2739

    Article  Google Scholar 

  3. Détaint D, Lepage L, Himbert D, Brochet E, Messika-Zeitoun D, Iung B, Vahanian A (2009) Determinants of significant paravalvular regurgitation after transcatheter aortic valve implantation: impact of device and annulus discongruence. JACC Cardiovasc Interv 2(9):821–827

    Article  Google Scholar 

  4. Khalique OK, Hahn RT, Gada H, Nazif TM, Vahl TP, George I, Kalesan B, Forster M, Williams MB, Leon MB (2014) Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement. JACC Cardiovasc Interv 7(8):885–894

    Article  Google Scholar 

  5. Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA (2012) SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr 6(6):366–380

    Article  Google Scholar 

  6. Smith LA, Dworakowski R, Bhan A, Delithanasis I, Hancock J, MacCarthy PA, Wendler O, Thomas MR, Monaghan MJ (2013) Real-time three-dimensional transesophageal echocardiography adds value to transcatheter aortic valve implantation. J Am Soc Echocardiogr 26(4):359–369

    Article  Google Scholar 

  7. Stella S, Italia L, Geremia G, Rosa I, Ancona F, Marini C, Capogrosso C, Giglio M, Montorfano M, Latib A, Margonato A, Colombo A, Agricola E (2019) Accuracy and reproducibility of aortic annular measurements obtained from echocardiographic 3D manual and semi-automated software analyses in patients referred for transcatheter aortic valve implantation: implication for prosthesis size selection. Eur Heart J Cardiovasc Imaging 20(1):45–55. https://doi.org/10.1093/ehjci/jey013

    Article  PubMed  Google Scholar 

  8. Fonseca P, Figueiredo B, Almeida C, Almeida J, Bettencourt N, Sampaio F, Ferreira N, Goncalves H, Braga P, Ribeiro VG (2016) Aortic valve calcium volume predicts paravalvular regurgitation and the need for balloon post-dilatation after transcatheter aortic valve implantation. J Interv Cardiol 29(1):117–123. https://doi.org/10.1111/joic.12267

    Article  PubMed  Google Scholar 

  9. Tamborini G, Fusini L, Muratori M, Cefalù C, Gripari P, Ali SG, Pontone G, Andreini D, Bartorelli AL, Alamanni F (2014) Feasibility and accuracy of three-dimensional transthoracic echocardiography vs. multidetector computed tomography in the evaluation of aortic valve annulus in patient candidates to transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging 15(12):1316–1323

    Article  Google Scholar 

  10. Podlesnikar T, Prihadi EA, van Rosendael PJ, Vollema EM, van der Kley F, de Weger A, Ajmone Marsan N, Naji F, Fras Z, Bax JJ, Delgado V (2018) Influence of the quantity of aortic valve calcium on the agreement between automated 3-dimensional transesophageal echocardiography and multidetector row computed tomography for aortic annulus sizing. Am J Cardiol 121(1):86–93. https://doi.org/10.1016/j.amjcard.2017.09.016

    Article  PubMed  Google Scholar 

  11. Prihadi EA, van Rosendael PJ, Vollema EM, Bax JJ, Delgado V, Ajmone Marsan N (2018) Feasibility, accuracy, and reproducibility of aortic annular and root sizing for transcatheter aortic valve replacement using novel automated three-dimensional echocardiographic software: comparison with multi-detector row computed tomography. J Am Soc Echocardiogr 31(4):505–514.e503. https://doi.org/10.1016/j.echo.2017.10.003

    Article  PubMed  Google Scholar 

  12. Mediratta A, Addetia K, Medvedofsky D, Schneider RJ, Kruse E, Shah AP, Nathan S, Paul JD, Blair JE, Ota T, Balkhy HH, Patel AR, Mor-Avi V (2017) 3D echocardiographic analysis of aortic annulus for transcatheter aortic valve replacement using novel aortic valve quantification software: comparison with computed tomography. Echocardiography (Mount Kisco, NY) 34(5):690–699. https://doi.org/10.1111/echo.13483

    Article  Google Scholar 

  13. Queiros S, Morais P, Fehske W, Papachristidis A, Voigt JU, Fonseca JC, D’Hooge J, Vilaca JL (2019) Assessment of aortic valve tract dynamics using automatic tracking of 3D transesophageal echocardiographic images. Int J Cardiovasc Imaging 35(5):881–895. https://doi.org/10.1007/s10554-019-01532-w

    Article  PubMed  Google Scholar 

  14. Tsang W, Bateman MG, Weinert L, Pellegrini G, Mor-Avi V, Sugeng L, Yeung H, Patel AR, Hill AJ, Iaizzo PA, Lang RM (2012) Accuracy of aortic annular measurements obtained from three-dimensional echocardiography, CT and MRI: human in vitro and in vivo studies. Heart (British Cardiac Society) 98(15):1146–1152. https://doi.org/10.1136/heartjnl-2012-302074

    Article  Google Scholar 

  15. García-Martín A, Lázaro-Rivera C, Fernández-Golfín C, Salido-Tahoces L, Moya-Mur J-L, Jiménez-Nacher J-J, Casas-Rojo E, Aquila I, González-Gómez A, Hernández-Antolín R (2016) Accuracy and reproducibility of novel echocardiographic three-dimensional automated software for the assessment of the aortic root in candidates for thanscatheter aortic valve replacement. Eur Heart J Cardiovasc Imaging 17(7):772–778

    Article  Google Scholar 

  16. Kasel AM, Cassese S, Bleiziffer S, Amaki M, Hahn RT, Kastrati A, Sengupta PP (2013) Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. JACC Cardiovasc Imaging 6(2):249–262. https://doi.org/10.1016/j.jcmg.2012.12.005

    Article  PubMed  Google Scholar 

  17. Vaquerizo B, Spaziano M, Alali J, Mylote D, Theriault-Lauzier P, Alfagih R, Martucci G, Buithieu J, Piazza N (2016) Three-dimensional echocardiography vs computed tomography for transcatheter aortic valve replacement sizing. Eur Heart J Cardiovasc Imaging 17(1):15–23. https://doi.org/10.1093/ehjci/jev238

    Article  PubMed  Google Scholar 

  18. Khalique OK, Hamid NB, White JM, Bae DJ, Kodali SK, Nazif TM, Vahl TP, Paradis JM, George I, Leon MB, Hahn RT (2017) Impact of methodologic differences in three-dimensional echocardiographic measurements of the aortic annulus compared with computed tomographic angiography before transcatheter aortic valve replacement. J Am Soc Echocardiogr 30(4):414–421. https://doi.org/10.1016/j.echo.2016.10.012

    Article  PubMed  Google Scholar 

  19. Husser O, Holzamer A, Resch M, Endemann DH, Nunez J, Bodi V, Schmid C, Riegger GA, Gossmann H, Hamer O, Stroszczynski C, Luchner A, Hilker M, Hengstenberg C (2013) Prosthesis sizing for transcatheter aortic valve implantation–comparison of three dimensional transesophageal echocardiography with multislice computed tomography. Int J Cardiol 168(4):3431–3438. https://doi.org/10.1016/j.ijcard.2013.04.182

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Francisco Sampaio.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

The study was approved by the local’s Ethics Committee and informed consent was obtained from all individual participants included in the study.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Maia, J., Ladeiras-Lopes, R., Guerreiro, C. et al. Accuracy of three-dimensional echocardiography in candidates for transcatheter aortic valve replacement. Int J Cardiovasc Imaging 36, 291–298 (2020). https://doi.org/10.1007/s10554-019-01716-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-019-01716-4

Keywords

Navigation