Abstract
Cardiac computed tomography angiography (cCTA) has recently been proposed for evaluation of successful interventional left atrial appendage closure (LAA/LAAC). This prospective longitudinal observational study aims to assess this proposal by applying a standardized imaging protocol to detect and quantify peri-device leaks (PDL) after LAAC. cCTA datasets of consecutive patients 6 months after successful LAAC were acquired on a third generation dual-source computed tomography system and reconstructed with a slice thickness of 0.5 mm. The standardized multi-planar reconstruction LAA occluder view for post-implantation evaluation (LOVE) algorithm was used to assess PDL in relation to LAA morphology and implanted LAAC devices. A total of 49 patients (median age 80 years, 24% female) were included consecutively. Overall PDL rate was 31%. Leak rates among different left atrial appendage morphologies varied largely. Windsock type had the highest incidence of PDL (47%). AMPLATZER™ AMULET™ device type revealed slightly higher PDL rates than WATCHMAN™ type and showed larger leaks. However, no statistical differences were found. PDL can be sized best in LOVE sagittal views, whereas a synopsis of LOVE sagittal, axial and coronal views allows further examination and detection of small leaks. PDL are common after successful interventional LAAC, which can be accurately detected and sized by standardized cCTA imaging protocols.
Similar content being viewed by others
References
Blackshear JL, Odell JA (1996) Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillation. Ann Thorac Surg 61(2):755–759. https://doi.org/10.1016/0003-4975(95)00887-X
Camm AJ, Lip GY, De Caterina R, Savelieva I, Atar D, Hohnloser SH, Hindricks G, Kirchhof P, Guidelines ESCCfP (2012) 2012 focused update of the ESC guidelines for the management of atrial fibrillation: an update of the 2010 ESC guidelines for the management of atrial fibrillation. Developed with the special contribution of the European Heart Rhythm Association. Eur Heart J 33(21):2719–2747. https://doi.org/10.1093/eurheartj/ehs253
Reddy VY, Doshi SK, Sievert H, Buchbinder M, Neuzil P, Huber K, Halperin JL, Holmes D, Investigators PA (2013) Percutaneous left atrial appendage closure for stroke prophylaxis in patients with atrial fibrillation: 2.3-year follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients with Atrial Fibrillation) trial. Circulation 127(6):720–729. https://doi.org/10.1161/CIRCULATIONAHA.112.114389
Viles-Gonzalez JF, Kar S, Douglas P, Dukkipati S, Feldman T, Horton R, Holmes D, Reddy VY (2012) The clinical impact of incomplete left atrial appendage closure with the watchman device in patients with atrial fibrillation: a PROTECT AF (percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation) substudy. J Am Coll Cardiol 59(10):923–929. https://doi.org/10.1016/j.jacc.2011.11.028
Bai R, Horton RP, L DIB, Mohanty P Pump A, Cardinal D, Scallon C, Mohanty S, Santangeli P, Brantes MC, Sanchez J, Burkhardt JD, Zagrodzky JD, Gallinghouse GJ, Natale A (2012) Intraprocedural and long-term incomplete occlusion of the left atrial appendage following placement of the WATCHMAN device: a single center experience. J Cardiovasc Electrophysiol 23(5):455–461. https://doi.org/10.1111/j.1540-8167.2011.02216.x
Jaguszewski M, Manes C, Puippe G, Salzberg S, Muller M, Falk V, Luscher T, Luft A, Alkadhi H, Landmesser U (2015) Cardiac CT and echocardiographic evaluation of peri-device flow after percutaneous left atrial appendage closure using the AMPLATZER cardiac plug device. Catheter Cardiovasc Interv 85(2):306–312. https://doi.org/10.1002/ccd.25667
Behnes M, Akin I, Sartorius B, Fastner C, El-Battrawy I, Borggrefe M, Haubenreisser H, Meyer M, Schoenberg SO, Henzler T (2016) LAA occluder view for post-implantation evaluation (LOVE)standardized imaging proposal evaluating implanted left atrial appendage occlusion devices by cardiac computed tomography. BMC Med Imaging 16:25. https://doi.org/10.1186/s12880-016-0127-y
Saw J, Tzikas A, Shakir S, Gafoor S, Omran H, Nielsen-Kudsk JE, Kefer J, Aminian A, Berti S, Santoro G, Nietlispach F, Moschovitis A, Cruz-Gonzalez I, Stammen F, Tichelbacker T, Freixa X, Ibrahim R, Schillinger W, Meier B, Sievert H, Gloekler S (2017) Incidence and clinical impact of device-associated thrombus and peri-device leak following left atrial appendage closure with the amplatzer cardiac plug. JACC Cardiovasc Interv 10(4):391–399. https://doi.org/10.1016/j.jcin.2016.11.029
Viles-Gonzalez JF, Reddy VY, Petru J, Mraz T, Grossova Z, Kralovec S, Neuzil P (2012) Incomplete occlusion of the left atrial appendage with the percutaneous left atrial appendage transcatheter occlusion device is not associated with increased risk of stroke. J Interv Card Electrophysiol 33(1):69–75. https://doi.org/10.1007/s10840-011-9613-x
Dieker W, Behnes M, Fastner C, Sartorius B, Wenke A, Sing-Gill I, El-Battrawy I, Kuschyk J, Papavassiliu T, Hoffmann U, Mashayekhi K, Schoenberg SO, Borggrefe M, Henzler T, Akin I (2018) Impact of left atrial appendage morphology on thrombus formation after successful left atrial appendage occlusion: Assessment with cardiac-computed-tomography. Sci Rep 8(1):1670. https://doi.org/10.1038/s41598-018-19385-z
Kirchhof P, Benussi S, Kotecha D, Ahlsson A, Atar D, Casadei B, Castella M, Diener HC, Heidbuchel H, Hendriks J, Hindricks G, Manolis AS, Oldgren J, Popescu BA, Schotten U, Van Putte B, Vardas P, Group ESCSD (2016) 2016 ESC guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Eur Heart J 37(38):2893–2962. https://doi.org/10.1093/eurheartj/ehw210
Fastner C, Behnes M, Sartorius B, Yildiz M, Mashayekhi K, El-Battrawy I, Lehmann R, Baumann S, Becher T, Borggrefe M, Akin I (2016) Left atrial appendage morphology, echocardiographic characterization, procedural data and in-hospital outcome of patients receiving left atrial appendage occlusion device implantation: a prospective observational study. BMC Cardiovasc Disord 16:25. https://doi.org/10.1186/s12872-016-0200-z
KDIGO (2012) Clinical practice guideline for the evaluation and management of chronic kidney disease. Kidney Int Suppl 3(1):1–150
Wang Y, Di Biase L, Horton RP, Nguyen T, Morhanty P, Natale A (2010) Left atrial appendage studied by computed tomography to help planning for appendage closure device placement. J Cardiovasc Electrophysiol 21(9):973–982. https://doi.org/10.1111/j.1540-8167.2010.01814.x
Lam SC, Bertog S, Sievert H (2015) Incomplete left atrial appendage occlusion and thrombus formation after watchman implantation treated with anticoagulation followed by further transcatheter closure with a second-generation amplatzer cardiac plug (Amulet device). Catheter Cardiovasc Interv 85(2):321–327. https://doi.org/10.1002/ccd.25456
Ismail TF, Panikker S, Markides V, Foran JP, Padley S, Rubens MB, Wong T, Nicol E (2015) CT imaging for left atrial appendage closure: a review and pictorial essay. J Cardiovasc Comput Tomogr 9(2):89–102. https://doi.org/10.1016/j.jcct.2015.01.011
Chung H, Jeon B, Chang HJ, Han D, Shim H, Cho IJ, Shim CY, Hong GR, Kim JS, Jang Y, Chung N (2015) Predicting peri-device leakage of left atrial appendage device closure using novel three-dimensional geometric CT analysis. J Cardiovasc Ultrasound 23(4):211–218. https://doi.org/10.4250/jcu.2015.23.4.211
Acknowledgements
Supported by the DZHK (Deutsches Zentrum fur Herz-Kreislauf-Forschung - German Centre for Cardiovascular Research).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. This study has been approved by the medical ethics committee II of the Faculty of Medicine Mannheim, University of Heidelberg, Germany.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Research involving human and animal participants
This article does not contain any studies with animals performed by any of the authors.
Rights and permissions
About this article
Cite this article
Lindner, S., Behnes, M., Wenke, A. et al. Assessment of peri-device leaks after interventional left atrial appendage closure using standardized imaging by cardiac computed tomography angiography. Int J Cardiovasc Imaging 35, 725–731 (2019). https://doi.org/10.1007/s10554-018-1493-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10554-018-1493-z