Abstract
Atherosclerotic disease within coronary arteries causes disruption of normal, laminar flow and generates flow turbulence. The characteristic acoustic waves generated by coronary turbulence serve as a novel diagnostic target. The frequency range and timing of microbruits associated with obstructive coronary artery disease (CAD) have been characterized. Technological advancements in sensor, data filtering and analytic capabilities may allow use of intracoronary turbulence for diagnostic and risk stratification purposes. Acoustic detection (AD) systems are based on the premise that the faint auditory signature of obstructive CAD can be isolated and analyzed to provide a new approach to noninvasive testing. The cardiac sonospectrographic analyzer, CADence, and CADScore systems are early-stage, investigational and commercialized examples of AD systems, with the latter two currently undergoing clinical testing with validation of accuracy using computed tomography and invasive angiography. Noninvasive imaging accounts for a large percentage of healthcare expenditures for cardiovascular disease in the developed world, and the growing burden of CAD will disproportionately affect areas in the developing world. AD is a portable, radiation-free, cost-effective method with the potential to provide accurate diagnosis or exclusion of significant CAD. AD represents a model for digital, miniaturized, and internet-connected diagnostic technologies.
Similar content being viewed by others
References
http://www.who.int/mediacentre/factsheets/fs317/en/. Accessed 4 Oct 2015
De Bruyne B, Pijls NHJ, Kalesan B, Barbato E, Tonino PAL, Piroth Z, Jagic N et al (2012) Fractional flow reserve-guided PCI versus medical therapy in stable coronary artery disease. N Engl J Med 367:991–1001
Levine GN, Bates ER, Blankenship JC, Lange RA, Mauri L, Mehran R et al (2011) ACCF/AHA/SCAI guideline for percutaneous coronary intervention. J Am Coll Cardiol 58:e44–e122
Windecker S, Kolh P, Alfonso F, Collet J-P, Cremer J, Falk V, Filippatos G et al (2014) ESC/EACTS guidelines on myocardial revascularization. Eur Heart J 35:2541–2619
Min JK, Leipsic J, Pencina MJ, Berman DS, Koo B-K, van Mieghem C et al (2012) Diagnostic accuracy of fractional flow reserve from anatomic CT angiography. JAMA 308:1237–1245
Nørgaard BL, Leipsic J, Gaur S, Seneviratne S, Ko BS, Ito H, Jensen JM et al (2014) Diagonstic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in suspected coronary artery disease. J Am Coll Cardiol 63:1145–1155
Dock W, Zoneraich Z (1967) A diastolic murmur arising in a stenosed coronary artery. Am J Med 42:617–619
Cheng TO (1970) Diastolic murmur caused by coronary artery stenosis. Ann Intern Med 72:543–546
Sangster JF, Oakley CM (1973) Diastolic murmur of coronary artery stenosis. Br Heart J 35:840–844
Fredburg JJ (1974) Pseudo-sound generation in atherosclerotic constrictions in arteries. Bull Math Biol 36:143–155
McKusick VA, Webb GN, Humphries JO, Reid JA (1955) On cardiovascular sound; further observations by means of spectral phonocardiography. Circulation 11:849–870
Semmlow J, Rahalkar K (2007) Acoustic detection of coronary artery disease. Annu Rev Biomed 9:449–469
Akay M, Welkowitz W, Semmlow JL, Kostis JB (1991) Application of the ARMA method to acoustic detection of coronary artery disease. Med Biol Eng Comput 29:365–372
Akay M, Akay YM, Welkowitz W, Semmlow JL, Kostis JB (1992) Application of adaptive filters to noninvasive acoustical detection of coronary occlusions before and after angioplasty. IEEE Trans Biomed Eng 39:176–184
Akay M, Akay YM, Gauthier D, Paden RG, Pavlicek W, Fortuin FD, Sweeney LP, Lee RW (2009) Dynamics of diastolic sounds caused by partially occluded coronary arteries. IEEE Trans Biomed Eng 56:513–517
Akay YM, Akay M, Welkowitz W, Semmlow JL, Kostis JB (1993) Noninvasive acoustical detection of coronary artery disease: a comparative study of signal processing methods. IEEE Trans Biomed Eng 40:571–578
Akay M, Welkowitz W, Semmlow JL, Akay YM, Kostis J (1992) Noninvasive acoustic detection of coronary artery disease using the adaptive line enhancer method. Med Biol Eng Comput 30:147–154
Akay M, Akay YM, Welkowitz W, Semmlow JL, Kostis J (1993) Application of adaptive FFT/FAST zero tracking filters to noninvasive characterization of the sound pattern caused by coronary artery stenosis before and after angioplasty. Ann Biomed Eng 21:9–17
Schmidt SE, Hansen J, Zimmermann Hammershøi D, Toft E, Struijk JJ (2011) Coronary artery disease and low frequency heart sound signatures. Comput Cardiol 38:481–484
Schmidt S, Holst-Hansen C, Hansen J, Toft E, Struijk J (2015) Acoustic features for the identification of coronary artery disease. IEEE Trans Biomed Eng 62(11):2611–2619
Borisyuk AO (2002) Experimental study of noise produced by steady flow through a simulated vascular stenosis. J Sound Vib 256:475–498
Makaryus AM, Makaryus JN, Figgatt A, Mulholland D, Kushner H, Semmlow JL, Meieres J, Taylor AJ (2013) Utility of an advanced digital electronic stethoscope in the diagnosis of coronary artery disease compared with coronary computed tomographic angiography. Am J Cardiol 111:786–792
Guion-Johnson MA, Madhu KP (2006) Using digital stethoscope data to diagnose stenosis in the left anterior descending coronary artery. Circulation 114(Suppl 2):600 (abstr)
http://aumcardio.com/. Accessed 18 Sept 2015
https://clinicaltrials.gov/ct2/show/NCT01743040. Accessed 18 Sept 2015
Hansen J, Zimmerman H, Schmidt SE Hammershøi D, Struijk JJ (2011) System for acquisition of weak murmurs related to coronary artery diseases. Comput Cardiol 38:213–216
Zimmerman H, Schmidt SE, Hansen J, Hammershøi D, Møller H (2011) Acoustic Coupler for Acquisition of Coronary Artery Murmurs. Comput Cardiol 38:209–212
http://acarix.com/technology/the-cadscorr-system. Accessed 20 Sept 2015
Winther S, Schmidt SE, Holm NR, Toft E, Struijk JJ, Bøtker HE, Bøttcher M (2016) Diagnosing coronary artery disease by sound analysis from coronary stenosis induced turbulent blood flow: diagnostic performance in patients with stable angina pectoris. Int J Cardiovasc Imaging 32:235–245
Nissen L, Winther S, Isaksen C, Ejlersen JA, Brix L, Urbonaviciene G, Frost L, Madsen LH, Knudsen LL, Schmidt SE et al (2016) Danish study of non-invasive testing in coronary artery disease (Dan-NICAD): study protocol for a randomised controlled trial. Trials 17:262
Azimpour F, Caldwell E, Tawfik P, Duval S RF, Wilson RF (2016) Audible coronary artery stenosis. Am J Med 129:515–521
Heidenreich PA, Trogdon JG, Khavjou OA, Butler J, Dracup K, Ezekowitz MD, Finkelstein EA et al (2011) Forecasting the future of cardiovascular disease in the United States. Circulation 123:933–944
Go AS, Mozaffarian D, Roger VL, Benjamin EJ, Berry JD, Borden WB et al; on behalf of the American Heart Association Statistics Committee and Stroke Statistics Subcommittee (2013) Heart disease and stroke statistics—2013 update. Circulation 127:e6–e245
Patel MR, Dai D, Hernandez AF, Douglas PS, Messenger J, Garratt KN, Maddox TM, Peterson ED, Roe MT (2014) Prevalence and predictors of nonobstructive coronary artery disease identified with coronary angiography in contemporary clinical practice. Am Heart J 167:846–852
Douglas PS, Hoffmann U, Patel MR, Mark DB, Al-Khalidi HR, Cavanaugh B, Cole J, Dolor RJ, Fordyce CB et al (2015) Outcomes of anatomical versus functional testing for coronary artery disease. N Engl J Med 372:1291–1300
Patel MR, Peterson ED, Dai D, Brennan JM, Redberg RF, Anderson V, Brindis RG, Douglas PS (2010) Low diagnostic yield of elective coronary angiography. N Engl J Med 362:886–895
Douglas PS, Taylor A, Bild D, Bonow R, Greenland P, Lauer M, Peacock F, Udelson J (2009) Outcomes research in cardiovascular imaging: report of a workshop sponsored by the national heart, lung and blood institute. J Am Soc Echocardiogr 22:766–773
Acknowledgements
JLT has received research grant support from AUM Cardiovascular, Inc. MB has received an unrestricted research grant from Acarix A/S.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
SW and RFW have disclosed no conflicts of interest.
Ethical approval
This article does not contain any studies with human participants or animals performed by any of the authors.
Rights and permissions
About this article
Cite this article
Thomas, J.L., Winther, S., Wilson, R.F. et al. A novel approach to diagnosing coronary artery disease: acoustic detection of coronary turbulence. Int J Cardiovasc Imaging 33, 129–136 (2017). https://doi.org/10.1007/s10554-016-0970-5
Received:
Accepted:
Published:
Issue Date: