Defining the optimal systolic phase targets using absolute delay time for reconstructions in dual-source coronary CT angiography

  • Original Paper
  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

To define the optimal systolic phase for dual-source computed tomography angiography using an absolute reconstruction delay time after the R–R interval based on the coronary artery motion, we analyzed images reconstructed between 200 and 420 miliseconds (ms) after the R wave at 20 ms increments in 21 patients. Based on the American Heart Association coronary segmentation guidelines, the origin of six coronary artery landmarks (RCA, AM1, PDA, LM, OM1, and D2) were selected to calculate the coronary artery motion velocity. The velocity of the given landmark was defined as the quotient of the route and the length of the time interval. The x, y and z-coordinates of the selected landmark were recorded, and were used for the calculation of the 3D route of coronary artery motion by using a specific equation. Differences in velocities were assessed by analysis of variance for repeated measures; Bonferroni post hoc tests were used for multiple pair wise comparisons. 1488 landmarks were measured (6 locations at 12 systolic time points) in 21 patients and were analyzed. The mean values of the minimum velocities were calculated separately for each heart rate group (i.e. <65; 65–80; and >80 bpm). The mean lowest coronary artery velocities in each segment occurred in the middle period of each time interval of the acquired systolic phase i.e. 280–340 ms. No differences were found in the minimal coronary artery velocities between the three HR groups, with the exception of the AM1 branch (p = 0.00495) between <65 and >80 bpm (p = 0.03), and at HRs of 65–80 versus >80 bpm (p = 0.006). During an absolute delay of 200–420 ms after the R-wave, the ideal reconstruction interval varies significantly among coronary artery segments. Decreased velocities occur between 280 to 340 ms. Therefore a narrow range of systolic intervals, rather than a single phase, should be acquired.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Achenbach S, Moshage W, Ropers D, Nossen J, Daniel WG (1998) Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions. N Engl J Med 339:1964–1971

    Article  PubMed  CAS  Google Scholar 

  2. Reddy GP, Chernoff DM, Adams JR, Higgins CB (1998) Coronary artery stenoses: assessment with contrast-enhanced electron-beam CT and axial reconstructions. Radiology 208:167–172

    Article  PubMed  CAS  Google Scholar 

  3. Little WC, Downes TR, Applegate RJ (1990) Invasive evaluation of left ventricular diastolic performance. Herz 15:362–376

    PubMed  CAS  Google Scholar 

  4. Leschka S, Husmann L, Desbiolles LM et al (2006) Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT. Eur Radiol 16:1964–1972

    Article  PubMed  Google Scholar 

  5. Bley TA, Ghanem NA, Foell D et al (2005) Computed tomography coronary angiography with 370-millisecond gantry rotation time: evaluation of the best image reconstruction interval. J Comput Assist Tomogr 29:1–5

    Article  PubMed  Google Scholar 

  6. Chung CS, Karamanoglu M, Kovacs SJ (2004) Duration of diastole and its phases as a function of heart rate during supine bicycle exercise. Am J Physiol Heart Circ Physiol 287:H2003–H2008

    Article  PubMed  CAS  Google Scholar 

  7. Mahabadi AA, Achenbach S, Burgstahler C et al (2010) Safety, efficacy, and indications of beta-adrenergic receptor blockade to reduce heart rate prior to coronary CT angiography. Radiology 257:614–623

    Article  PubMed  Google Scholar 

  8. Gharib AM, Herzka DA, Ustun AO et al (2007) Coronary MR angiography at 3T during diastole and systole. J Magn Reson Imaging 26:921–926

    Article  PubMed  Google Scholar 

  9. Shin T, Pohost GM, Nayak KS (2010) Systolic 3D first-pass myocardial perfusion MRI: Comparison with diastolic imaging in healthy subjects. Magn Reson Med 63:858–864

    Article  PubMed  Google Scholar 

  10. Seifarth H, Wienbeck S, Pusken M et al (2007) Optimal systolic and diastolic reconstruction windows for coronary CT angiography using dual-source CT. AJR Am J Roentgenol 189:1317–1323

    Article  PubMed  Google Scholar 

  11. Herzog C, Abolmaali N, Balzer JO et al (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678

    PubMed  Google Scholar 

  12. Marwan M, Hausleiter J, Abbara S et al (2014) Multicenter Evaluation Of Coronary Dual-Source CT angiography in patients with intermediate Risk of Coronary Artery Stenoses (MEDIC): study design and rationale. J Cardiovasc Comput Tomogr 8:183–188

    Article  PubMed  Google Scholar 

  13. Johnson TR, Nikolaou K, Wintersperger BJ et al (2006) Dual-source CT cardiac imaging: initial experience. Eur Radiol 16:1409–1415

    Article  PubMed  Google Scholar 

  14. Lee AM, Beaudoin J, Engel LC et al (2013) Assessment of image quality and radiation dose of prospectively ECG-triggered adaptive dual-source coronary computed tomography angiography (cCTA) with arrhythmia rejection algorithm in systole versus diastole: a retrospective cohort study. Int J Cardiovasc Imaging 29:1361–1370

    Article  PubMed  Google Scholar 

  15. Ritchie CJ, Godwin JD, Crawford CR, Stanford W, Anno H, Kim Y (1992) Minimum scan speeds for suppression of motion artifacts in CT. Radiology 185:37–42

    Article  PubMed  CAS  Google Scholar 

  16. Lee AM, Engel LC, Shah B et al (2012) Coronary computed tomography angiography during arrhythmia: radiation dose reduction with prospectively ECG-triggered axial and retrospectively ECG-gated helical 128-slice dual-source CT. J Cardiovasc Comput Tomogr 6(172–183):e2

    PubMed  Google Scholar 

  17. Ghoshhajra BB, Engel LC, Karolyi M et al (2013) Cardiac computed tomography angiography with automatic tube potential selection: effects on radiation dose and image quality. J Thorac Imaging 28:40–48

    Article  PubMed  Google Scholar 

  18. Austen WG, Edwards JE, Frye RL et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the ad hoc committee for grading of coronary artery disease, council on cardiovascular surgery, American heart association. Circulation 51:5–40

    Article  PubMed  CAS  Google Scholar 

  19. Husmann L, Leschka S, Desbiolles L et al (2007) Coronary artery motion and cardiac phases: dependency on heart rate—implications for CT image reconstruction. Radiology 245:567–576

    Article  PubMed  Google Scholar 

  20. Wang Y, Vidan E, Bergman GW (1999) Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology 213:751–758

    Article  PubMed  CAS  Google Scholar 

  21. Boudoulas H, Geleris P, Lewis RP, Rittgers SE (1981) Linear relationship between electrical systole, mechanical systole, and heart rate. Chest 80:613–617

    Article  PubMed  CAS  Google Scholar 

  22. Adler G, Meille L, Rohnean A, Sigal-Cinqualbre A, Capderou A, Paul JF (2010) Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients. Eur Radiol 20:1118–1123

    Article  PubMed  Google Scholar 

  23. Kim HY, Lee JW, Hong YJ et al (2012) Dual-source coronary CT angiography in patients with high heart rates using a prospectively ECG-triggered axial mode at end-systole. Int J Cardiovasc Imaging 28(Suppl 2):101–107

    Article  PubMed  Google Scholar 

  24. Paul JF, Amato A, Rohnean A (2013) Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine. Int J Cardiovasc Imaging 29:651–657

    PubMed  Google Scholar 

  25. Okada M, Nakashima Y, Shigemoto Y et al (2011) Systolic reconstruction in patients with low heart rate using coronary dual-source CT angiography. Eur J Radiol 80:336–341

    Article  PubMed  Google Scholar 

  26. Hausleiter J, Meyer TS, Martuscelli E et al (2012) Image quality and radiation exposure with prospectively ECG-triggered axial scanning for coronary CT angiography: the multicenter, multivendor, randomized PROTECTION-III study. JACC Cardiovasc Imaging 5:484–493

    Article  PubMed  Google Scholar 

  27. Luisada AA, MacCanon DM (1972) The phases of the cardiac cycle. Am Heart J 83:705–711

    Article  PubMed  CAS  Google Scholar 

  28. Fabian J, Epstein EJ, Coulshed N (1972) Duration of phases of left ventricular systole using indirect methods, I. Normal subjects. Br Heart J 34:874–881

    Article  PubMed  CAS  PubMed Central  Google Scholar 

  29. Mollet NR, Cademartiri F, de Feyter PJ (2005) Non-invasive multislice CT coronary imaging. Heart 91:401–407

    Article  PubMed  PubMed Central  Google Scholar 

  30. Pannu HK, Flohr TG, Corl FM, Fishman EK (2003) Current concepts in multi-detector row CT evaluation of the coronary arteries: principles, techniques, and anatomy. Radiographics 23 Spec No: S111-25

  31. Boehm T, Husmann L, Leschka S, Desbiolles L, Marincek B, Alkadhi H (2007) Image quality of the aortic and mitral valve with CT: relative versus absolute delay reconstruction. Acad Radiol 14:613–624

    Article  PubMed  Google Scholar 

  32. Bloomfield GS, Gillam LD, Hahn RT et al (2012) A practical guide to multimodality imaging of transcatheter aortic valve replacement. JACC Cardiovasc Imaging 5:441–455

    Article  PubMed  Google Scholar 

  33. Wang Y, Qin L, Shi X et al (2012) Adenosine-stress dynamic myocardial perfusion imaging with second-generation dual-source CT: comparison with conventional catheter coronary angiography and SPECT nuclear myocardial perfusion imaging. AJR Am J Roentgenol 198:521–529

    Article  PubMed  Google Scholar 

  34. Taillefer R, Ahlberg AW, Masood Y et al (2003) Acute beta-blockade reduces the extent and severity of myocardial perfusion defects with dipyridamole Tc-99 m sestamibi SPECT imaging. J Am Coll Cardiol 42:1475–1483

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Brian Ghoshhajra.

Ethics declarations

Conflict of interest

None.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Celeng, C., Vadvala, H., Puchner, S. et al. Defining the optimal systolic phase targets using absolute delay time for reconstructions in dual-source coronary CT angiography. Int J Cardiovasc Imaging 32, 91–100 (2016). https://doi.org/10.1007/s10554-015-0755-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-015-0755-2

Keywords

Navigation