Abstract
Purpose The objective of this trial was to investigate the capacity of gated perfusion SPECT (GPS) to detect left ventricular aneurysm (ANV) by comparing QGS and 4D-MSPECT (4DM) algorithms with radionuclide ventriculography (RVG). Secondarily, the comparison of GPS ejection fraction (EF) measurements with those of contrast left ventriculography (LVG) and RVG was aimed. Methods Twenty-five patients with ANV confirmed by LVG were studied. The patients underwent RVG and rest Tc-99m-tetrofosmin GPS 1 week after LVG. A 9-segment model was used both in RVG and GPS evaluation. Aneurysm was defined by scoring the wall motion (WM) and phase analysis in RVG; perfusion, wall thickening and WM in GPS. Results The detection rate of ANV was 96%, 84% and 52% for RVG, QGS and 4DM, respectively. The LVG mean EF (43.52% ± 16.93%) was significantly higher (P < 0.01) than those of RVG (29.40% ± 10.90), QGS (30.04% ± 13.25%) and 4DM (34.92% ± 13.01%). Moderate to high EF correlation values were obtained between LVG and GPS (r = 0.71–0.79) and GPS–RVG (r = 0.69). There was no significant EF difference between the radionuclide methods except between 4DM–EF and RVG–EF (5.52%, P < 0.05). Wide Bland–Altman limits were observed between the radionuclide methods in EF comparisons (range: 30.5–38.5%). Conclusion GPS seems to have a role in the non-invasive investigation of ANV. QGS–GPS proved to be more reliable (84%) than 4DM–GPS (52%) in the ANV detection. The localization and the extent of the aneurysm itself as well as perfusion and function of adjacent segments may affect aneurysm diagnosis by means of GPS. RVG, QGS–GPS and 4DM–GPS seem not to be interchangeable for routine EF calculation in ANV patients.
Similar content being viewed by others
References
Rigo P, Murray M, Strauss HW et al (1974) Scintiphotographic evaluation of patients with suspected left ventricular aneurysm. Circulation 5:985–991
Friedman MI, Cantor RE (1979) Reliability of gated heart scintigrams for detection of left ventricular aneurysm: concise communication. J Nucl Med 20:720–723
Williams KA, Taillon LA (1996) Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion images. Comparison with assessment by contrast ventriculography and first-pass radionuclide angiography. J Am Coll Cardiol 27:173–181
Germano G, Kiat H, Kavanagh PB et al (1995) Automatic quantification of ejection fraction from gated sestamibi SPECT. J Nucl Med 36:2138–2147
Ioannidis JP, Trikalinos TA, Danias PG (2002) Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: a meta-analysis. J Am Coll Cardiol 39:2059–2068
Vourvouri EC, Poldermans D, Bax JJ et al (2001) Evaluation of left ventricular function and volumes in patients with ischemic cardiomyopathy: gated single-photon emission computed tomography versus two-dimensional echocardiography. Eur J Nucl Med 28:1610–1615
Higuchi T, Nakajima K, Taki J, Kinuya S, Bunko H, Tonami N et al (2001) Assessment of left ventricular systolic and diastolic function based on the edge detection method with myocardial ECG-gated SPET. Eur J Nucl Med 28:1512–1516
Abe M, Kazatani Y, Fukuda H et al (2000) Left ventricular volumes, ejection fraction, and regional wall motion calculated with gated technetium-99m tetrofosmin SPECT in reperfused acute myocardial infarction at super-acute phase: comparison with left ventriculography. J Nucl Cardiol 7:569–574
Germano G, Berman D (2003) Gated SPECT. In: Iskandrian AE, Verani MS (eds) Nuclear cardiac imaging. Oxford University Press, New York, pp 121–136
Gorlin R, Klein MD, Sullivan JM (1967) Prospective correlative study of ventricular aneurysm. Mechanistic concept and clinical recognition. Am J Med 42:512–531
Moralidis E, Spyridonidis T, Arsos G et al (2004) Tl-201 gated single photon emission computed tomographic myocardial perfusion imaging in the assessment of global and regional left ventricular function. Would it be favoured over equilibrium radionuclide angiography? Nucl Med Commun 25:665–673
Hansen CL, Goldstein RA, Berman DS (2006) Imaging guidelines for nuclear cardiology procedures. A report of the American Society of Nuclear Cardiology Quality Assurance Committee: myocardial perfusion and function single photon emission computed tomography. J Nucl Cardiol 13:97–120
Botvinick EH, Dae MW, O’Connel JW (1997) Functional imaging and phase analysis of blood pool imaging. In: Gerson MC (ed) Cardiac nuclear medicine, 3rd edn. McGraw Hill, New York
Mangschau A (1989) Akinetic versus dyskinetic left ventricular aneurysm diagnosed by gated scintigraphy: difference in surgical outcome. Ann Thorac Surg 47:746–751
Pennell DJ, Prvulovich E (1995) Image interpretation: nuclear cardiology. British Nuclear Medicine Society, London, pp 56–79
Berman DS, Germano G (2006) Interpretation and reporting of gated myocardial perfusion SPECT. In: Berman DS, Germano G (eds) Clinical gated cardiac SPECT, 2nd edn. Blackwell Publishing, UK
Matthias Bechtel JF, Tolg R, Graf B et al (2004) High incidence of sudden death late after anterior LV-aneurysm repair. Eur J Cardiothorac Surg 25:807–811
Movahed MR, Vu J, Lizotte P (2006) Failure of gated SPECT and echocardiography to detect large apical aneurysm secondary to hyperdynamic left ventricular wall at the aneurysm neck. Cardiovasc Revasc Med 7:250–254
Konen E, Merchant N, Gutierrez C et al (2005) True versus false left ventricular aneurysm: differentiation with MR imaging—initial experience. Radiology 236:65–70
Versteegh MI, Lamb HJ, Bax JJ et al (2003) MRI evaluation of left ventricular function in anterior LV aneurysms before and after surgical resection. Eur J Cardiothorac 23:609–651
Wagner A, Mahrholdt H, Holly TA et al (2003) Contrast-enhanced MRI and routine single photon emission computed tomography (SPECT) perfusion imaging for detection of subendocardial myocardial infarcts: an imaging study. Lancet 361:374–379
Nakajima K, Higuchi T, Taki J et al (2001) Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs. J Nucl Med 42:1571–1578
Abe K, Hirakawa K, Yonenaga T et al (2005) Assessment of left ventricular ejection fraction measured by quantitative gated SPECT correlation with left ventriculography and first-pass radionuclide angiography. Int J Cardiovasc Imaging 22:223–230
Atsma DE, Bavelaar-Croon CD, Germano G et al (2000) Good correlation between gated single photon emission computed myocardial tomography and contrast ventriculography in the assessment of global and regional left ventricular function. Int J Card Imaging 16:447–453
Kouris K, Abdel-Dayem HM, Taha B et al (1992) Left ventricular ejection fraction and volumes calculated from dual gated SPECT myocardial imaging with 99Tcm-MIBI. Nucl Med Commun 13:648–655
Wright GA, McDade M, Keeble W et al (2000) Quantitative gated SPECT myocardial perfusion imaging with 201Tl: an assessment of the limitations. Nucl Med Commun 21:1147–1151
Nichols K, DePuey EG, Rozanski A (1996) Automation of gated tomographic left ventricular ejection fraction. J Nucl Cardiol 3:475–482
Canbaz F, Basoglu T, Yapici O et al (2006) Myocardial perfusion defects with near-to-absent count reduction: a comparison of gated SPECT to radionuclide ventriculography in the determination of left ventricular function. Int J Cardiovasc Imaging 22:231–241
Chua T, Yin LC, Thiang TH et al (2000) Accuracy of the automated assessment of left ventricular function with gated perfusion SPECT in the presence of perfusion defects and left ventricular dysfunction: correlation with equilibrium radionuclide ventriculography and echocardiography. J Nucl Cardiol 7:301–311
Wynne J, Green LH, Mann T et al (1978) Estimation of left ventricular volumes in man from biplane cineangiograms filmed in oblique projections. Am J Cardiol 41:726–732
Yoshioka J, Hasegawa S, Yamaguchi H et al (1999) Left ventricular volumes and ejection fraction calculated from quantitative electrocardiographic-gated 99mTc-tetrofosmin myocardial SPECT. J Nucl Med 40:1693–1698
Lipke CS, Kuhl HP, Nowak B et al (2004) Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging. Eur J Nucl Med Mol Imaging 31:482–490
Nichols K, Tamis J, DePuey EG et al (1998) Relationship of gated SPECT ventricular function parameters to angiographic measurements. J Nucl Cardiol 5:295–303
Manrique A, Faraggi M, Ve´ra P et al (1999) A 201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction. Comparison with equilibrium radionuclide angiography. J Nucl Med 40:805–809
Lum DP, Coel MN (2003) Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT. Nucl Med Commun 24:259–266
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Canbaz, F., Basoglu, T., Durna, K. et al. Left ventricular aneurysm in the scope of gated perfusion SPECT: accuracy of detection and ejection fraction calculation. Int J Cardiovasc Imaging 24, 585–596 (2008). https://doi.org/10.1007/s10554-008-9298-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10554-008-9298-0