Skip to main content

MDCT and virtual angioscopy in spontaneous aortocaval fistula

Abstract

Aortocaval fistula is a rare, less than 1%, but life threatening complication, of abdominal aortic aneurysm. Mortality is high but prompt recognition of the fistula can reduce mortality rate. The multidetector row CT (MDCT) findings in a 69-year-old patient with a complex medical history characterized by previous episodes of myocardial ischemia, is reported. MDCT shows an early homogeneous enhancement of the inferior vena cava, slightly dilated at the liver level and markedly narrowed above the renal vein due to aneurysm compression. The patient underwent to emergency laparotomy but died during surgery for cardiac arrest. MDCT allows a prompt recognition of the fistula and different computerized reconstruction techniques as maximum intensity projection (MIP), multiplanar reformatting (MPR) and virtual angioscopy (VA) added imaging information for surgery.

This is a preview of subscription content, access via your institution.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

References

  1. Davidovic LB, Kostic DM, Cvetkovic SD, Jakovljevic NS, Stojanov PL, Kacar AS et al. (2002) Aorto-caval fistulas. Cardiovasc Surg 10:555–560

    PubMed  Article  CAS  Google Scholar 

  2. Leigh-Smith S, Smith RC (2005) Aorto caval fistula – the “bursting heart syndrome”. J Accid Emerg Med 17:223–224

    Google Scholar 

  3. Fenster MS, Dent JM, Tribble C, Angle JF, Sarembock IJ, Komada M et al (1996) Aortocaval fistula complicating abdominal aortic aneurysm: case report and literature review. Cathet Cardiovasc Diagn 38:236–238

    Article  Google Scholar 

  4. Cura M, Cura A, Bugnone A (2003) Early enhancement of the inferior vena cava on helical CT. Clin Imaging 27:236–238

    PubMed  Article  Google Scholar 

  5. Rajmohan B(2002) Spontaneous aortocaval fistula. J Postgrad Med 48:203–205

    PubMed  CAS  Google Scholar 

  6. Coulier B, Tilquin O, Etienne P-Y (2004) Multidetector row CT diagnosis of aortocaval fistula complicating aortic aneurysm: a case report. Emerg Radiol 11:100–103

    PubMed  Article  Google Scholar 

  7. Lin PH, Bush RL, Lumsden AB (2004) Aortocaval fistula. J Vasc Surg 39:266–268

    PubMed  Article  Google Scholar 

  8. Brunkwall J, Lanne T, Bergentz S-E (1999) Acute renal impairment due to a primary aortocaval fistula is normalised after a successful operation. Eur J Vasc Endovasc Surg 17:191–196

    PubMed  Article  CAS  Google Scholar 

  9. Rosenthal D, Atkins C, Jerrius HS, Clark MD, Matsuura JH (1998) Diagnosis of aortocaval fistula by computed tomography. Ann Vasc Surg 12:86–87

    PubMed  Article  CAS  Google Scholar 

  10. Unterweger M, Wiesner W, Pretre R, Marincek B (2000) Spiral CT in an acute spontaneous aorto-caval fistula. Eur Radiol 10:733–735

    PubMed  Article  CAS  Google Scholar 

  11. Carrascosa P, Capunay C, Vembar M, Ciancibello L, Carrascosa J (2005) Multislice CT angioscopy of the abdomen. Abdom Imaging 30:249–258

    PubMed  Article  CAS  Google Scholar 

Download references

Author information

Affiliations

Authors

Corresponding author

Correspondence to Sergio Salerno.

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Salerno, S., Romano, I., De Luca, T. et al. MDCT and virtual angioscopy in spontaneous aortocaval fistula. Int J Cardiovasc Imaging 23, 635–638 (2007). https://doi.org/10.1007/s10554-006-9158-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-006-9158-8

Keywords

  • Aorta
  • Cava
  • Fistula
  • Multidetector row CT
  • Virtual Angioscopy