Abstract
Background: Clinical progress by the development of multi-slice CT (MSCT) technology beyond 16 slices can more likely be expected from further improved spatial and temporal resolution rather than from a mere increase in the volume coverage speed. We present an evaluation of a recently introduced 64-slice CT (64SCT) system, which makes use of a periodic motion of the focal spot in the longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. Materials and Methods: A recently introduced 64SCT system (SOMATOM Sensation 64, Siemens Medical Solutions, Forchheim, Germany) is being described and tested in first clinical practice, applying the following parameters: z-flying focal spot technology, 64×0.6 mm slices; spatial resolution, 0.4 × 0.4 × 0.4 mm; gantry rotation time, 330 ms; temporal resolution, 83–165 ms. Various phantom studies and first clinically implemented protocols are being described, to evaluate the full spectrum of possible applications for this scanner type, with a focus on cardiac imaging. Results:ECG-gated cardiac scanning with this 64-slice CT system benefits clearly from both the improved temporal resolution and improved spatial resolution. These benefits enable a more reliable assessment of mixed plaques, due to reduced partial-voluming and beam-hardening artefacts caused by calcifications, and holds great promise for the reliable assessment of in-stent stenoses, as stent lumen visibility is clearly improved as compared to earlier MSCT systems. With the increased volume coverage and acquisition speed of the 64SCT system, a comprehensive emergency protocol of the thorax becomes feasible within an acceptable breath-hold time, performing an ECG-gated CT angiography of the complete thoracic vasculature. This protocol enables a detailed assessment of the thoracic aorta, the pulmonary arteries and the coronary arteries in one single examination. Conclusion:64SCT Cardiac imaging provides an increased spatial resolution with an isotropic voxel size of 0.4 mm and an improved temporal resolution of 83–165 ms. These benefits hold great promise especially for fast-moving organs requiring detailed imaging, such as the heart and coronary arteries.
Similar content being viewed by others
References
B Ohnesorge T Flohr C Becker et al. (2000) ArticleTitleCardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience Radiology 217(2) 564–571
BJ Wintersperger K Nikolaou TF Jakobs MF Reiser CR Becker (2003) ArticleTitleCardiac multidetector-row computed tomography: initial experience using 16 detector-row systems Crit Rev Comput Tomogr 44 IssueID1 27–45 Occurrence Handle12627782
K Nikolaou M Poon M Sirol CR Becker ZA Fayad (2003) ArticleTitleComplementary results of computed tomography and magnetic resonance imaging of the heart and coronary arteries: a review and future outlook Cardiol Clin 21 IssueID4 639–655 Occurrence Handle14719573
ZA Fayad V Fuster K Nikolaou C Becker (2002) ArticleTitleComputed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging: current and potential future concepts Circulation 106 IssueID15 2026–2034
T Flohr K Stierstorfer H Bruder J Simon S Schaller (2002) ArticleTitleNew technical developments in multislice CT–part 1: approaching isotropic resolution with sub-millimeter 16-slice scanning Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174 IssueID7 839–845 Occurrence Handle10.1055/s-2002-32692 Occurrence Handle1:STN:280:DC%2BD38zlslKqug%3D%3D Occurrence Handle12101473
T Flohr H Bruder K Stierstorfer J Simon S Schaller B Ohnesorge (2002) ArticleTitleNew technical developments in multislice CT, part 2: sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174 IssueID8 1022–1027 Occurrence Handle10.1055/s-2002-32930 Occurrence Handle1:STN:280:DC%2BD38zpsVamsg%3D%3D Occurrence Handle12142982
M Dewey M Laule L Krug et al. (2004) ArticleTitleMultisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses Invest Radiol 39 IssueID4 223–229
K Nieman F Cademartiri P Lemos R Raaijmakers P Pattynama P Feyter Particlede (2002) ArticleTitleReliable noninvasive coronary aniography with fast submillimeter multslice spiral computed tomography Circulation 106 2051–2054
D Ropers U Baum K Pohle et al. (2003) ArticleTitleDetection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction Circulation 107 IssueID5 664–666
K Nikolaou CR Becker M Muders U Loehrs M Reiser ZA Fayad (2004) ArticleTitleHigh resolution magnetic resonance and multi-slice CT imaging of coronary artery plaques in human ex vivo coronary arteries Atherosclerosis 174 IssueID2 243–252
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Nikolaou, K., Flohr, T., Knez, A. et al. Advances in cardiac CT imaging: 64-slice scanner. Int J Cardiovasc Imaging 20, 535–540 (2004). https://doi.org/10.1007/s10554-004-7015-1
Issue Date:
DOI: https://doi.org/10.1007/s10554-004-7015-1