Advances in cardiac CT imaging: 64-slice scanner

  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

Background: Clinical progress by the development of multi-slice CT (MSCT) technology beyond 16 slices can more likely be expected from further improved spatial and temporal resolution rather than from a mere increase in the volume coverage speed. We present an evaluation of a recently introduced 64-slice CT (64SCT) system, which makes use of a periodic motion of the focal spot in the longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. Materials and Methods: A recently introduced 64SCT system (SOMATOM Sensation 64, Siemens Medical Solutions, Forchheim, Germany) is being described and tested in first clinical practice, applying the following parameters: z-flying focal spot technology, 64×0.6 mm slices; spatial resolution, 0.4 × 0.4 × 0.4 mm; gantry rotation time, 330 ms; temporal resolution, 83–165 ms. Various phantom studies and first clinically implemented protocols are being described, to evaluate the full spectrum of possible applications for this scanner type, with a focus on cardiac imaging. Results:ECG-gated cardiac scanning with this 64-slice CT system benefits clearly from both the improved temporal resolution and improved spatial resolution. These benefits enable a more reliable assessment of mixed plaques, due to reduced partial-voluming and beam-hardening artefacts caused by calcifications, and holds great promise for the reliable assessment of in-stent stenoses, as stent lumen visibility is clearly improved as compared to earlier MSCT systems. With the increased volume coverage and acquisition speed of the 64SCT system, a comprehensive emergency protocol of the thorax becomes feasible within an acceptable breath-hold time, performing an ECG-gated CT angiography of the complete thoracic vasculature. This protocol enables a detailed assessment of the thoracic aorta, the pulmonary arteries and the coronary arteries in one single examination. Conclusion:64SCT Cardiac imaging provides an increased spatial resolution with an isotropic voxel size of 0.4 mm and an improved temporal resolution of 83–165 ms. These benefits hold great promise especially for fast-moving organs requiring detailed imaging, such as the heart and coronary arteries.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • B Ohnesorge T Flohr C Becker et al. (2000) ArticleTitleCardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience Radiology 217(2) 564–571

    Google Scholar 

  • BJ Wintersperger K Nikolaou TF Jakobs MF Reiser CR Becker (2003) ArticleTitleCardiac multidetector-row computed tomography: initial experience using 16 detector-row systems Crit Rev Comput Tomogr 44 IssueID1 27–45 Occurrence Handle12627782

    PubMed  Google Scholar 

  • K Nikolaou M Poon M Sirol CR Becker ZA Fayad (2003) ArticleTitleComplementary results of computed tomography and magnetic resonance imaging of the heart and coronary arteries: a review and future outlook Cardiol Clin 21 IssueID4 639–655 Occurrence Handle14719573

    PubMed  Google Scholar 

  • ZA Fayad V Fuster K Nikolaou C Becker (2002) ArticleTitleComputed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging: current and potential future concepts Circulation 106 IssueID15 2026–2034

    Google Scholar 

  • T Flohr K Stierstorfer H Bruder J Simon S Schaller (2002) ArticleTitleNew technical developments in multislice CT–part 1: approaching isotropic resolution with sub-millimeter 16-slice scanning Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174 IssueID7 839–845 Occurrence Handle10.1055/s-2002-32692 Occurrence Handle1:STN:280:DC%2BD38zlslKqug%3D%3D Occurrence Handle12101473

    Article  CAS  PubMed  Google Scholar 

  • T Flohr H Bruder K Stierstorfer J Simon S Schaller B Ohnesorge (2002) ArticleTitleNew technical developments in multislice CT, part 2: sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174 IssueID8 1022–1027 Occurrence Handle10.1055/s-2002-32930 Occurrence Handle1:STN:280:DC%2BD38zpsVamsg%3D%3D Occurrence Handle12142982

    Article  CAS  PubMed  Google Scholar 

  • M Dewey M Laule L Krug et al. (2004) ArticleTitleMultisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses Invest Radiol 39 IssueID4 223–229

    Google Scholar 

  • K Nieman F Cademartiri P Lemos R Raaijmakers P Pattynama P Feyter Particlede (2002) ArticleTitleReliable noninvasive coronary aniography with fast submillimeter multslice spiral computed tomography Circulation 106 2051–2054

    Google Scholar 

  • D Ropers U Baum K Pohle et al. (2003) ArticleTitleDetection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction Circulation 107 IssueID5 664–666

    Google Scholar 

  • K Nikolaou CR Becker M Muders U Loehrs M Reiser ZA Fayad (2004) ArticleTitleHigh resolution magnetic resonance and multi-slice CT imaging of coronary artery plaques in human ex vivo coronary arteries Atherosclerosis 174 IssueID2 243–252

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Konstantin Nikolaou.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nikolaou, K., Flohr, T., Knez, A. et al. Advances in cardiac CT imaging: 64-slice scanner. Int J Cardiovasc Imaging 20, 535–540 (2004). https://doi.org/10.1007/s10554-004-7015-1

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-004-7015-1

Keywords

Navigation