Abstract
The choice of an electroencephalogram (EEG) reference has fundamental importance and could be critical during clinical decision-making because an impure EEG reference could falsify the clinical measurements and subsequent inferences. In this research, the suitability of three EEG references was compared while classifying depressed and healthy brains using a machine-learning (ML)-based validation method. In this research, the EEG data of 30 unipolar depressed subjects and 30 age-matched healthy controls were recorded. The EEG data were analyzed in three different EEG references, the link-ear reference (LE), average reference (AR), and reference electrode standardization technique (REST). The EEG-based functional connectivity (FC) was computed. Also, the graph-based measures, such as the distances between nodes, minimum spanning tree, and maximum flow between the nodes for each channel pair, were calculated. An ML scheme provided a mechanism to compare the performances of the extracted features that involved a general framework such as the feature extraction (graph-based theoretic measures), feature selection, classification, and validation. For comparison purposes, the performance metrics such as the classification accuracies, sensitivities, specificities, and F scores were computed. When comparing the three references, the diagnostic accuracy showed better performances during the REST, while the LE and AR showed less discrimination between the two groups. Based on the results, it can be concluded that the choice of appropriate reference is critical during the clinical scenario. The REST reference is recommended for future applications of EEG-based diagnosis of mental illnesses.
Similar content being viewed by others
References
Acharya UR, Sudarshan VK, Adeli H, Santhosh J, Koh JE, Adeli A (2015a) Computer-aided diagnosis of depression using EEG signals. Euro Neurol 73(5–6):329–336
Acharya UR, Sudarshan VK, Adeli H, Santhosh J, Koh JE, Puthankatti SD, Adeli A (2015b) A novel depression diagnosis index using nonlinear features in EEG signals. Eur Neurol 74(1–2):79–83
American Psychiatric Association (2013) Diagnostic and statistical manual of mental disorders (DSM-5®): American Psychiatric Association, Arlington
Bairy GM, Lih OS, Hagiwara Y, Puthankattil SD, Faust O, Niranjan U, Acharya UR (2017) Automated diagnosis of depression electroencephalograph signals using linear prediction coding and higher order spectra features. J Med Imaging Health Inf 7(8):1857–1862
Berg P, Scherg M (1994) A multiple source approach to the correction of eye artifacts. Electroencephalogr Clin Neurophysiol 90(3):229–241
Boutros NN, Arfken C, Galderisi S, Warrick J, Pratt G, Iacono W (2008) The status of spectral EEG abnormality as a diagnostic test for schizophrenia. Schizophr Res 99(1):225–237
Chella F, Pizzella V, Zappasodi F, Marzetti L (2016) Impact of the reference choice on scalp EEG connectivity estimation. J Neural Eng 13(3):036016
Dien J (1998) Issues in the application of the average reference: review, critiques, and recommendations. Behav Res Methods Instrum Comput 30(1):34–43
Dong L, Li F, Liu Q, Wen X, Lai Y, Xu P, Yao D (2017) MATLAB toolboxes for reference electrode standardization technique (REST) of scalp EEG. Front Neurosci 11:601
Faust O, Ang PCA, Puthankattil SD, Joseph PK (2014) Depression diagnosis support system based on EEG signal entropies. J Mech Med Biol 14(03):1450035
Ferree TC (2006) Spherical splines and average referencing in scalp electroencephalography. Brain Topogr 19(1–2):43–52
Fried SJ, Smith DM, Legatt AD (2014) Median nerve somatosensory evoked potential monitoring during carotid endarterectomy: does reference choice matter? J Clin Neurophysiol 31(1):55–57
Geselowitz DB (1998) The zero of potential. IEEE Eng Med Biol Mag 17(1):128–136
Hoechstetter K, Berg P, Scherg M (2010). BESA research tutorial 4: distributed source imaging. BESA Res Tutorial, 1–29
Hosseinifard B, Moradi MH, Rostami R (2013) Classifying depression patients and normal subjects using machine learning techniques and nonlinear features from EEG signal. Comput Methods Programs Biomed 109(3):339–345
Hu S, Lai Y, Valdés-Sosa PA, Brings-Vega ML, Yao D (2017) How do the reference montage and electrodes setup affect the measured scalp EEG potentials? J Neural Eng 15:026013
Jasper HH (1958) The ten twenty electrode system of the international federation. Electroencephalogr Clin Neurophysiol 10:371–375
Junghöfer M, Elbert T, Tucker DM, Braun C (1999) The polar average reference effect: a bias in estimating the head surface integral in EEG recording. Clin Neurophysiol 110(6):1149–1155
Jurcak V, Tsuzuki D, Dan I (2007) 10/20, 10/10, and 10/5 systems revisited: their validity as relative head-surface-based positioning systems. Neuroimage 34(4):1600–1611
Knott V, Mahoney C, Kennedy S, Evans K (2001) EEG power, frequency, asymmetry and coherence in male depression. Psychiatry Res 106(2):123–140
Lei X, Liao K (2017) Understanding the influences of EEG reference: a large-scale brain network perspective. Front Neurosci 11:205
Liao S-C, Wu C-T, Huang H-C, Cheng W-T, Liu Y-H (2017) Major depression detection from EEG signals using kernel eigen-filter-bank common spatial patterns. Sensors 17(6):1385
Liu H, Motoda H (2007) Computational methods of feature selection. CRC Press, Boca Raton
Liu Q, Balsters JH, Baechinger M, van der Groen O, Wenderoth N, Mantini D (2015) Estimating a neutral reference for electroencephalographic recordings: the importance of using a high-density montage and a realistic head model. J Neural Eng 12(5):056012
Mahmud WMRW., Awang A, Herman I, Mohamed MN (2004) Analysis of the psychometric properties of the Malay version of Beck Depression Inventory II (BDI-II) among postpartum women in Kedah, North West of Peninsular Malaysia. Malays J Med Sci 11(2):19
Mamitsuka H (2006) Selecting features in microarray classification using ROC curves. Pattern Recogn 39(12):2393–2404
McLachlan G (2004) Discriminant analysis and statistical pattern recognition, vol 544. Wiley, Hoboken
Mumtaz W, Ali SSA, Yasin MAM, Malik AS (2017a) A machine learning framework involving EEG-based functional connectivity to diagnose major depressive disorder (MDD). Med Biol Eng Comput 56:233–246
Mumtaz W, Xia L, Ali SSA, Yasin MAM, Hussain M, Malik AS (2017b) Electroencephalogram (EEG)-based computer-aided technique to diagnose major depressive disorder (MDD). Biomed Signal Process Control 31:108–115
Musa R, Fadzil MA, Zain Z (2007) Translation, validation and psychometric properties of Bahasa Malaysia version of the Depression Anxiety and Stress Scales (DASS). ASEAN J Psychiatry 8(2):82–89
Nunez PL (2010) REST: a good idea but not the gold standard. Clin Neurophysiol 121(12):2177–2180
Osselton J (1965) Acquisition of EEG data by bipolar unipolar and average reference methods: a theoretical comparison. Electroencephalogr Clin Neurophysiol 19(5):527–528
Puthankattil SD, Joseph PK (2012) Classification of EEG signals in normal and depression conditions by ANN using RWE and signal entropy. J Mech Med Biol 12(04):1240019
Qin Y, Xu P, Yao D (2010) A comparative study of different references for EEG default mode network: the use of the infinity reference. Clin Neurophysiol 121(12):1981–1991
Qin Y, Xin X, Zhu H, Li F, Xiong H, Zhang T, Lai Y (2017) A comparative study on the dynamic EEG center of mass with different references. Front Neurosci 11:509
Stam C, Van Dijk B (2002) Synchronization likelihood: an unbiased measure of generalized synchronization in multivariate data sets. Physica D 163(3):236–251
Suykens JA, Vandewalle J (1999) Least squares support vector machine classifiers. Neural Process Lett 9(3):293–300
Tian Y, Yao D (2013) Why do we need to use a zero reference? Reference influences on the ERPs of audiovisual effects. Psychophysiology 50(12):1282–1290
Tiwari AK, Pachori RB, Kanhangad V, Panigrahi BK (2017) Automated diagnosis of epilepsy using key-point-based local binary pattern of EEG signals. IEEE J Biomed Health Inf 21(4):888–896
Trujillo LT, Stanfield CT, Vela RD (2017) The effect of electroencephalogram (EEG) reference choice on information-theoretic measures of the complexity and integration of EEG signals. Front Neurosci 11:425
Xu P, Xiong XC, Xue Q, Tian Y, Peng Y, Zhang R et al (2014) Recognizing mild cognitive impairment based on network connectivity analysis of resting EEG with zero reference. Physiological measurement 35(7):1279
Yang P, Fan C, Wang M, Li L (2017) A comparative study of average, linked mastoid, and REST references for ERP components acquired during fMRI. Front Neurosci 11:247
Yao D (2001) A method to standardize a reference of scalp EEG recordings to a point at infinity. Physiol Meas 22(4):693
Yao D (2017) Is the surface potential integral of a dipole in a volume conductor always zero? A cloud over the average reference of EEG and ERP. Brain Topogr 30(2):161–171
Yao D, Wang L, Oostenveld R, Nielsen KD, Arendt-Nielsen L, Chen AC (2005) A comparative study of different references for EEG spectral mapping: the issue of the neutral reference and the use of the infinity reference. Physiol Meas 26(3):173
Acknowledgements
The research work is funded by the Ministry of Higher Education Malaysia (Cost Center: 0153CA-005).
Author information
Authors and Affiliations
Corresponding author
Additional information
Handling Editor: Dezhong Yao.
Rights and permissions
About this article
Cite this article
Mumtaz, W., Malik, A.S. A Comparative Study of Different EEG Reference Choices for Diagnosing Unipolar Depression. Brain Topogr 31, 875–885 (2018). https://doi.org/10.1007/s10548-018-0651-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10548-018-0651-x