Skip to main content
Log in

An intelligent intestinal bleeding diagnosis and treatment capsule system based on color recognition

  • Published:
Biomedical Microdevices Aims and scope Submit manuscript
  • 1 Altmetric

Abstract

To our best knowledge, there are no non-invasive and painless means for the diagnosis and treatment of intestinal bleeding as of now, especially the segment of intestine that cannot be reached by endoscopy. We proposed an intelligent intestinal bleeding diagnosis and treatment capsule (IBDTC) system for the first time to diagnose and treat intestinal bleeding with low power consumption, estimated to be about 2.16mW. A hue-saturation-light (HSL) color space method was applied to diagnose bleeding according to H (hue) values of the film dyed by blood. A MEMS-based micro-igniter works as the critical component of the micro-thruster that houses the propellant (74.6% potassium nitrate, 11.9% sulfur, 13.5% charcoal) and the detonating agent (dinitrodiazophenol), to help release drug. Bleeding detection and ignition tests were performed to justify its feasibility and reliability. Results demonstrated that the bleeding diagnosis module of the IBDTC can effectively detect bleeding and the micro-igniter can successfully ignite the propellant. Owing to its simplicity and intelligence, the IBDTC system will pave a way for future accurate treatment of small intestinal bleeding with no injury, no pain, no complicated supporting equipment, no need for in vitro operation and positioning.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11

Similar content being viewed by others

Abbreviations

IBDTC:

Intestinal bleeding diagnosis and treatment capsule

HSL:

Hue-saturation-light

MEMS:

Micro-Electro-Mechanical Systems

LED:

Light emitting diode

RGB:

Red-Green–Blue

QFN:

Quad Flat No-lead

SMD:

Surface Mounted Devices

LPCVD:

Low-pressure chemical vapor deposition

PCB:

Printed Circuit Board

PBS:

Phosphate buffered solution

DC:

Direct current

References

Download references

Acknowledgements

The authors would like to thank Chongqing University Cancer Hospital for providing experimental materials.

Funding

This study was funded by the National Natural Science Foundation of China (Grant Number 81671850).

Author information

Authors and Affiliations

Authors

Contributions

Panpan Qiao: Methodology, Investigation, Writing–Original Draft, Visualization; Luo Yu: Formal analysis, Validation; Hongying Liu: Resources, Data Curation, Writing–Review & Editing, Funding acquisition; Xueping Yan: Software; Xitian Pi: Conceptualization, Supervision, Project administration.

Corresponding authors

Correspondence to Panpan Qiao, Hongying Liu or Xitian Pi.

Ethics declarations

Conflicts of interest/Competing interests

The authors declare that they have no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Qiao, P., Yu, L., Liu, H. et al. An intelligent intestinal bleeding diagnosis and treatment capsule system based on color recognition. Biomed Microdevices 25, 6 (2023). https://doi.org/10.1007/s10544-022-00642-y

Download citation

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s10544-022-00642-y

Keywords

Navigation