Abstract
Cell sorters play important roles in biological and medical applications, such as cellular behavior study and disease diagnosis and therapy. This work presents a label-free microfluidic sorter that has a downstream-pointing magnetic elastic diverter. Different with most existing magnetic sorters, the proposed device does not require the target microobjects to be intrinsically magnetic or coated with magnetic particles, giving users more flexibility in sorting criteria. The diverter is wirelessly deformed by an applied magnetic field, and its deformation induces a fluid vortex that sorts incoming microobjects, e.g., cells, to the collection outlet. The diverter does not touch samples in this process, reducing the sample contamination and damage risks. This sorter uses a magnetic field generated by off-chip electromagnetic coils that are centimeters away from the device. With simple structure and no on-chip circuits or coils, this device can be integrated with other lab-on-a-chip instruments in a sealed chip, ameliorating the safety concerns in handling hazardous samples. The parallel and independent control of two such diverters on a single chip were demonstrated, showing the potential of doubling the overall throughput or forming a two-stage cascaded sorter. The sorter was modeled based on the Euler-Bernoulli beam theory and its reliability was demonstrated by achieving a raw success rate of 96.68% in sorting 1506 registered microbeads. With a simple structure, the sorter is easy and cheap to fabricate. The advantages of the proposed sorter make it a promising multi-purpose sorting tool in both academic and industrial applications.
This is a preview of subscription content, access via your institution.







References
J.D. Adams, U. Kim, H.T. Soh, Multitarget magnetic activated cell sorter. Proc. Natl. Acad. Sci. USA. 105(47), 18165–18170 (2008)
R.W. Applegate, J. Squier, T. Vestad, J. Oakey, D.W.M. Marr, P. Bado, M.A. Dugan, A.A. Said, Microfluidic sorting system based on optical waveguide integration and diode laser bar trapping. Lab Chip. 6(3), 422–426 (2006)
B.J. Bain, I. Bates, M.A. Laffan, S.M. Lewis, Dacie and Lewis practical haematology (2011)
C. Carr, M. Espy, P. Nath, S.L. Martin, M.D. Ward, J. Martin, Design, fabrication and demonstration of a magnetophoresis chamber with 25 output fractions. J. Magn. Magn. Mater. 321(10), 1440–1445 (2009)
C.H. Chen, S.H. Cho, F. Tsai, A. Erten, Y.H. Lo, Microfluidic cell sorter with integrated piezoelectric actuator. Biomed. Microdevices. 11(6), 1223–1231 (2009)
Y. Chen, A.J. Chung, T.H. Wu, M.A. Teitell, D. Di Carlo, P.Y. Chiou, Pulsed laser activated cell sorting with three dimensional sheathless inertial focusing. Small. 10(9), 1746–1751 (2014)
P.Y. Chiou, A.T. Ohta, M.C. Wu, Massively parallel manipulation of single cells and microparticles using optical images. Nature. 436(7049), 370–372 (2005)
S. Choi, S. Song, C. Choi, J.K. Park, Continuous blood cell separation by hydrophoretic filtration. Lab Chip. 7(11), 1532–1538 (2007)
D. Di Carlo, D. Irimia, R.G. Tompkins, M. Toner, Continuous inertial focusing, ordering, and separation of particles in microchannels. Proc. Natl. Acad. Sci. USA. 104(48), 18892–18897 (2007)
E. Diller, M. Sitti, Micro-scale mobile robotics. Found Trends Robot. 2(3), 143–259 (2011)
X. Ding, S.C.S. Lin, B. Kiraly, H. Yue, S. Li, I.K. Chiang, J. Shi, S.J. Benkovic, T.J. Huang, On-chip manipulation of single microparticles, cells, and organisms using surface acoustic waves. Proc. Natl. Acad. Sci. USA. 109(28), 11105–11109 (2012)
M.D. Estes, J. Do, C.H. Ahn, On chip cell separator using magnetic bead-based enrichment and depletion of various surface markers. Biomed. Microdevices. 11(2), 509–515 (2009)
M.A. Faridi, H. Ramachandraiah, I. Iranmanesh, D. Grishenkov, M. Wiklund, A. Russom, MicroBubble activated acoustic cell sorting. Biomed. Microdevices. 19(2), 23 (2017)
J.Y. Gauthier, C. Lexcellent, A. Hubert, J. Abadie, N. Chaillet, Magneto-thermo-mechanical modeling of a magnetic shape memory alloy Ni-Mn-Ga single crystal. Ann. Solid Struct. Mech. 2(1), 19–31 (2011)
F. Guo, X.H. Ji, K. Liu, R.X. He, L.B. Zhao, Z.X. Guo, W. Liu, S.S. Guo, X.Z. Zhao, Droplet electric separator microfluidic device for cell sorting. Appl. Phys. Lett. 96(19). doi:10.1063/1.3360812 (2010)
C.T. Ho, R.Z. Lin, H.Y. Chang, C.H. Liu, Micromachined electrochemical T-switches for cell sorting applications. Lab Chip. 5(11), 1248–1258 (2005)
H.W. Hou, A.A.S. Bhagat, W.C. Lee, S. Huang, J. Han, C.T. Lim, Microfluidic devices for blood fractionation. Micromachines. 2(3), 319–343 (2011)
P. Howell, J. Golden, L. Hilliard, J. Erickson, D. Mott, F. Ligler, Two simple and rugged designs for creating microfluidic sheath flow. Lab Chip. 8(7), 1097–1103 (2008)
S.C. Hur, N.K. Henderson-MacLennan, E.R.B. McCabe, D. Di Carlo, Deformability-based cell classification and enrichment using inertial microfluidics. Lab Chip. 11(5), 912–920 (2011)
D.W. Inglis, R. Riehn, R.H. Austin, J.C. Sturm, Continuous microfluidic immunomagnetic cell separation. Appl. Phys. Lett. 85(21), 5093–5095 (2004)
R. Johann, P. Renaud, A simple mechanism for reliable particle sorting in a microdevice with combined electroosmotic and pressure-driven flow. Electrophoresis. 25(21–22), 3720–3729 (2004)
I.D. Johnston, D.K. McCluskey, C.K.L. Tan, M.C. Tracey, Mechanical characterization of bulk Sylgard 184 for microfluidics and microengineering. J. Micromech. Microeng. 24, 035017 (2014)
A. Lenshof, T. Laurell, Continuous separation of cells and particles in microfluidic systems. Chem. Soc. Rev. 39(3), 1203–1217 (2010)
S. Li, X. Ding, Z. Mao, Y. Chen, N. Nama, F. Guo, P. Li, L. Wang, C.E. Cameron, T.J. Huang, Standing surface acoustic wave (SSAW)-based cell waching. Lab Chip. 15, 331–338 (2015)
J. Lin, K. Owsley, M. Bahr, E. Diebold, D.D. Carlo, A frequency-multiplexed, microfluidic parallel flow cytometer for high-throughput screening. In: 20th International Conference on Miniaturized Systems for Chemistry and Life Sciences, pp. 208–209 (2016)
M. Liu, J. Sun, Y. Sun, C. Bock, Q. Chen, Thickness-dependent mechanical properties of polydimethylsiloxane membranes. J. Micromech. Microeng. 19(3), 035028 (2009)
M.P. MacDonald, G.C. Spalding, K. Dholakia, Microfluidic sorting in an optical lattice. Nature 426, 421–424 (2003)
D. Mattanovich, N. Borth, Applications of cell sorting in biotechnology. Microb. Cell Fact. 5(1), 12 (2006)
L. Mazutis, J. Gilbert, W.L. Ung, D.A. Weitz, A.D. Griffiths, J.A. Heyman, Single-cell analysis and sorting using droplet-based microfluidics. Nat. Protocols. 8(5), 870–891 (2013)
B. Michel, A. Bernard, A. Bietsch, E. Delamarche, M. Geissler, D. Juncker, H. Kind, J.P. Renault, H. Rothuizen, H. Schmid, P. SchmidtWinkel, R. Stutz, H. Wolf, Printing meets lithography: soft approaches to high-resolution patterning (vol 45, pg 697, 2001). IBM J. Res. Dev. 45(6), 870 (2001)
B. Nelson, I. Kaliakatsos, J. Abbott, Microrobots for minimally invasive medicine. Annu. Rev. Biomed. Eng. 12, 55–85 (2010)
J. Nguyen, Y. Wei, Y. Zheng, C. Wang, Y. Sun, On-chip sample preparation for complete blood count from raw blood. Lab Chip. 15(6), 1533–1544 (2015)
A.T. Ohta, P.Y. Chiou, T.H. Han, J.C. Liao, U. Bhardwaj, E.R.B. McCabe, F. Yu, R. Sun, M.C. Wu, Dynamic cell and microparticle control via optoelectronic tweezers. J. Microelectromech. Syst. 16(3), 491–499 (2007)
Q. Ramadan, V. Samper, D.P. Poenar, C. Yu, An integrated microfluidic platform for magnetic microbeads separation and confinement. Biosens. Bioelectron. 21(9), 1693–1702 (2006)
X. Ren, M. Bachman, C. Sims, G.P. Li, N. Allbritton, Electroosmotic properties of microfluidic channels composed of poly(dimethylsiloxane). J. Chromatogr. B Biomed. Sci. Appl. 762(2), 117–125 (2001)
A. Russom, A.K. Gupta, S. Nagrath, D.D. Carlo, J.F. Edd, M. Toner, Differential inertial focusing of particles in curved low-aspect-ratio microchannels. New J Phys. 11(7), 075025 (2009)
L. Schmid, D. Weitz, T. Franke, Sorting drops and cells with acoustics: acoustic microfluidic fluorescence-activated cell sorter. Lab Chip. 14(19), 3710–3718 (2014)
G.J. Shah, A.T. Ohta, E.P.Y. Chiou, M.C. Wu, C.J. Kim, EWOD-driven droplet microfluidic device integrated with optoelectronic tweezers as an automated platform for cellular isolation and analysis. Lab Chip. 9(12), 1732–1739 (2009)
C. Wyatt Shields IV, C. Reyes, G. López, Microfluidic cell sorting: a review of the advances in the separation of cells from debulking to rare cell isolation. Lab Chip. 15(5), 1230–1249 (2015)
S.L. Stott, C.H.C.H. Hsu, D.I. Tsukrov, M. Yu, D.T. Miyamoto, Ba. Waltman, S.M. Rothenberg, A.M. Shah, M.E. Smas, G.K. Korir, F.P. Floyd, A.J. Gilman, J.B. Lord, D. Winokur, S. Springer, D. Irimia, S. Nagrath, L.V. Sequist, R.J. Lee, K.J. Isselbacher, S. Maheswaran, Da. Haber, M. Toner, Isolation of circulating tumor cells using a microvortex-generating herringbone-chip. Proc Natl Acad Sci USA. 18(35), 392–397 (2010)
P. Szaniszlo, N. Wang, M. Sinha, L.M. Reece, J.W. Van Hook, B. Luxon, J.F. Leary, Getting the right cells to the array: gene expression microarray analysis of cell mixtures and sorted cells. Cytometry A. 59, 191–202 (2004)
L. Wang, La. Flanagan, E. Monuki, N.L. Jeon, A.P. Lee, Dielectrophoresis switching with vertical sidewall electrodes for microfluidic flow cytometry. Lab Chip. 7(9), 1114–20 (2007)
X. Wang, S. Chen, M. Kong, Z. Wang, K. Costa, R. Li, D. Sun, Enhanced cell sorting and manipulation with combined optical tweezer and microfluidic chip technologies. Lab Chip. 11, 3656–3662 (2011)
M.E. Warkiani, G. Guan, K.B. Luan, W.C. Lee, A.A.S. Bhagat, P.K. Chaudhuri, D.S.W. Tan, W.T. Lim, S.C. Lee, P.C.Y. Chen, C.T. Lim, J. Han, Slanted spiral microfluidics for the ultra-fast, label-free isolation of circulating tumor cells. Lab Chip. 14(1), 128–37 (2014)
H.W. Wu, X.Z. Lin, S.M. Hwang, G.B. Lee, A microfluidic device for separation of amniotic fluid mesenchymal stem cells utilizing louver-array structures. Biomed Microdevices. 11(6), 1297–1307 (2009)
Y. Yamanishi, S. Sakuma, K. Onda, F. Arai, Powerful actuation of magnetized microtools by focused magnetic field for particle sorting in a chip. Biomed. Microdevices. 12, 745–752 (2010)
M. Zborowski, J.J. Chamers, Rare cell separation and analysis by magnetic sorting. Anal. Chem. 83(21), 8050–8056 (2011)
J. Zhang, E. Diller, Tetherless mobile micrograsping using a magnetic elastic composite material. Smart Mater. Struct. 25, 11LT03 (2016)
J. Zhang, P. Jain, E. Diller, Independent control of two millimeter-scale soft-bodied magnetic robotic swimmers. In: IEEE International Conference on Robotics and Automation, pp. 1933–1938 (2016)
J. Zhang, O. Onaizah, K. Middleton, L. You, E. Diller, Reliable grasping of three-dimensional untethered mobile magnetic microgripper for autonomous pick-and-place. IEEE Robot. Autom. Lett. 2(2), 835–840 (2017)
Acknowledgements
The authors acknowledge the use of the Centre for Microfluidic Systems in Chemistry and Biology at the University of Toronto for providing equipment access.
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
(MP4 3.45 MB)
(MP4 1.09 MB)
(MP4 3.44 MB)
Rights and permissions
About this article
Cite this article
Zhang, J., Onaizah, O., Sadri, A. et al. A generic label-free microfluidic microobject sorter using a magnetic elastic diverter. Biomed Microdevices 19, 43 (2017). https://doi.org/10.1007/s10544-017-0183-2
Published:
DOI: https://doi.org/10.1007/s10544-017-0183-2