Development, manufacturing and application of double-sided flexible implantable microelectrodes

  • Published:
Biomedical Microdevices Aims and scope Submit manuscript

Abstract

Many neuroprosthetic applications require the use of very small, flexible multi-channel microelectrodes (e.g. polyimide-based film-like electrodes) to fit anatomical constraints. By arranging the electrode contacts on both sides of the polyimide film, selectivity can be further increased without increasing size. In this work, two approaches to create such double-sided electrodes are described and compared: sandwich electrodes prepared by precisely gluing two single-sided structures together, and monolithic electrodes created using a new double-sided photolithography process. Both methods were successfully applied to manufacture double-sided electrodes for stimulation of the vestibular system. In a case study, the electrodes were implanted in the semicircular canals of three guinea pigs and proven to provide electrical stimulation of the vestibular nerve. For both the monolithic electrodes and the sandwich electrodes, long-term stability and functionality was observed over a period of more than 12 months. Comparing the two types of electrodes with respect to the manufacturing process, it can be concluded that monolithic electrodes are the preferred solution for very thin electrodes (<20 μm), while sandwich electrode technology is especially suitable for thicker electrodes (40–50 μm).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11

Similar content being viewed by others

References

  • K.D. Wise et al., Wireless implantable microsystems: High-density electronic interfaces to the nervous system. Proc. IEEE 92, 76–97 (Jan 2004)

  • S.P. Lacour et al., Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces. Med. Biol. Eng. Comput. 48, 945–954 (Oct 2010)

  • T. Lefurge et al., Chronically Implanted Intrafascicular Recording Electrodes. Ann. Biomed. Eng. 19, 197–207 (1991)

    Article  Google Scholar 

  • V.S. Polikov et al., Response of brain tissue to chronically implanted neural electrodes. J. Neurosci. Methods 148, 1–18 (2005)

    Article  Google Scholar 

  • T. Stieglitz et al., Micromachined, Polyimide-Based Devices for flexible interfaces. Biomed. Microdevices 2, 283–294 (2000)

    Article  Google Scholar 

  • K.P. Gao et al., Fabrication of flexible microelectrode arrays integrated with microfluidic channels for stable neural interfaces. Sensors Actuators A Phys. 197, 9–14 (2013)

    Article  Google Scholar 

  • A. Blau et al., Flexible, all-polymer microelectrode arrays for the capture of cardiac and neuronal signals. Biomaterials 32, 1778–1786 (Mar 2011)

  • J.H. Choi et al., High Resolution Electroencephalography in Freely Moving Mice. J. Neurophysiol. 104, 1825–1834 (Sep 2010)

  • P.J. Rousche et al., Flexible polyimide-based intracortical electrode arrays with bioactive capability. IEEE Trans. Biomed. Eng. 48, 361–371 (Mar 2001)

  • K.C. Cheung et al., Flexible polyimide microelectrode array for in vivo recordings and current source density analysis. Biosens. Bioelectron. 22, 1783–1790 (2007)

    Article  Google Scholar 

  • D.B. Shire et al., Development and Implantation of a Minimally Invasive Wireless Subretinal Neurostimulator. Ieee Transactions on Biomedical Engineering 56, 2502–2511 (Oct 2009)

  • B. Rubehn, T. Stieglitz, In vitro evaluation of the long-term stability of polyimide as a material for neural implants. Biomaterials 31, 3449–3458 (May 2010)

  • Y. Sun et al., Assessment of the biocompatibility of photosensitive polyimide for implantable medical device use. J. Biomed. Mater. Res. 90A, 648–655 (2009)

  • N. Lago et al., Long term assessment of axonal regeneration through polyimide regenerative electrodes to interface the peripheral nerve. Biomaterials 26, 2021–2031 (May 2005)

  • D. Ceballos et al., Morphologic and functional evaluation of peripheral nerve fibers regenerated through polyimide sieve electrodes over long-term implantation. J. Biomed. Mater. Res. 60, 517–528 (2002)

    Article  Google Scholar 

  • T. Stieglitz et al., “Microflex” - A new assembling technique for interconnects. J. Intell. Mater. Syst. Struct. 11, 417–425 (Jun 2000)

  • J. DiGiovanna et al., Development of a closed-loop neural prosthesis for vestibular disorders. Journal of Automatic Control 20, 27–32 (2010)

    Article  Google Scholar 

  • W.S. Gong, D.M. Merfeld, System design and performance of a unilateral horizontal semicircular canal prosthesis. Ieee Transactions on Biomedical Engineering 49, 175–181 (Feb 2002)

  • D.M. Merfeld et al., Acclimation to chronic constant-rate peripheral stimulation provided by a vestibular prosthesis. Ieee Transactions on Biomedical Engineering 53, 2362–2372 (Nov 2006)

  • C.C. Della Santina et al., A multichannel semicircular canal neural prosthesis using electrical stimulation to restore 3-D vestibular sensation. Ieee Transactions on Biomedical Engineering 54, 1016–1030 (Jun 2007)

  • K. Nie et al., An experimental vestibular neural prosthesis: design and preliminary results with rhesus monkeys stimulated with modulated pulses. IEEE Trans. Biomed. Eng. 60, 1685–1692 (Jun 2013)

  • T.L. Rose, L.S. Robblee, Electrical-Stimulation with Pt Electrodes.8. Electrochemically Safe Charge Injection Limits with 0.2 Ms Pulses. Ieee Transactions on Biomedical Engineering 37, 1118–1120 (Nov 1990)

  • T. Stieglitz, Flexible biomedical microdevices with double-sided electrode arrangements for neural applications. Sensors and Actuators a-Physical 90, 203–211 (2001)

    Article  Google Scholar 

  • T. Stieglitz, M. Gross, Flexible BIOMEMS with electrode arrangements on front and back side as key component in neural prostheses and biohybrid systems. Sensors and Actuators B-Chemical 83, 8–14 (2002)

    Article  Google Scholar 

  • S. Metz et al., Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity. Biosens. Bioelectron. 19, 1309–1318 (2004)

    Article  Google Scholar 

  • A. Tooker et al., Polymer neural interface with dual-sided electrodes for neural stimulation and recording. Conf Proc IEEE Eng Med Biol Soc 2012, 5999–6002 (2012)

    Google Scholar 

  • S.F. Cogan, Neural stimulation and recording electrodes. Annu. Rev. Biomed. Eng. 10, 275–309 (2008)

    Article  Google Scholar 

  • H. Jansen et al., The Black Silicon Method - a Universal Method for Determining the Parameter Setting of a Fluorine-Based Reactive Ion Etcher in Deep Silicon Trench Etching with Profile Control. J. Micromech. Microeng. 5, 115–120 (Jun 1995)

  • A. Ramachandran et al., Design, in vitro and in vivo assessment of a multi-channel sieve electrode with integrated multiplexer. J. Neural Eng. 3, 114–124 (Jun 2006)

  • A. Bahmer et al., Recording and analysis of electrically evoked compound action potentials (ECAPs) with MED-EL cochlear implants and different artifact reduction strategies in Matlab. J. Neurosci. Methods 191, 66–74 (2010)

    Article  Google Scholar 

  • T. A. K. Nguyen, et al., "Investigating ocular movements and Vestibular Evoked Potentials for a vestibular neuroprosthesis: Response to pulse trains and baseline stimulation," presented at the 6th International IEEE/EMBS Conference on Neural Engineering, San Diego, 2013

  • W. Poppendieck, et al., ‘A measurement set-up to determine the charge injection capacity of neural microelectrodes,’ in 11th World Congress on Medical Physics and Biomedical Engineering, Munich, 2009, pp. 162–165.

  • K. Nie et al., Characterization of the electrically evoked compound action potential of the vestibular nerve. Otol Neurotol 32, 88–97 (Jan 2011)

  • T. A. K. Nguyen, et al., ‘Investigating Vestibular Evoked Potentials as Feedback Signal in a Vestibular Neuroprosthesis: Relation to Eye Movement Velocity,’ in International Conference on Neurorehabilitation, Toledo, 2012, pp. 1325–1329.

  • J. Du et al., High-resolution three-dimensional extracellular recording of neuronal activity with microfabricated electrode arrays. J. Neurophysiol. 101, 1671–1678 (Mar 2009)

  • V. Sridhar, K. Takahata, A hydrogel-based passive wireless sensor using a flex-circuit inductive transducer. Sensors and Actuators a-Physical 155, 58–65 (Oct 2009)

  • M.F. Suesserman et al., In vitro measurement and characterization of current density profiles produced by non-recessed, simple recessed, and radially varying recessed stimulating electrodes. IEEE Trans. Biomed. Eng. 38, 401–408 (May 1991)

Download references

Acknowledgments

This work was supported by the European Commission in the Future & Emerging Technologies Open Scheme, Project 225929 (CLONS – A Closed-Loop Neural Prosthesis for Vestibular Disorders).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Wigand Poppendieck.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Poppendieck, W., Sossalla, A., Krob, MO. et al. Development, manufacturing and application of double-sided flexible implantable microelectrodes. Biomed Microdevices 16, 837–850 (2014). https://doi.org/10.1007/s10544-014-9887-8

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10544-014-9887-8

Keywords

Navigation