This study reports a transparent indium tin oxide (ITO)-based microheater chip and its applicability for perfusion cell culture outside a cell incubator. The attempt of the proposed ITO microheater is to take the role of conventional bulky incubator for cell culture in order to improve integratability with the experimental setup for continuous/perfusion cell culture, to facilitate microscopic observation or other online monitoring activities during cell culture, or even to provide portability of cell culture operation. In this work, numerical simulation and experimental evaluation have been conducted to justify that the presented device is capable of providing a spatially uniform thermal environment and precise temperature control with a mild deviation of ±0.2°C, which is suitable for a general cell culture practice. Besides, to testify that the thermal environment generated by the presented device is well compatible with conventional cell incubator, chondrocyte perfusion culture was carried out. Results demonstrated that the physiology of the cultured chondrocytes on the developed ITO microheater chip was consistent with that of an incubator. All these not only demonstrate the feasibility of using the presented ITO microheater as a thermal control system for cell culture outside a cell incubator but also reveal its potential for other applications in which excellent thermal control is required.

Keywords

Microheater Indium tin oxide ITO Temperature control Perfusion cell culture Microbioreactor 

References

  1. C. Brandam, C. Castro-Martínez, M.L. Délia, F. Ramón-Portugal, P. Strehaiano, Effect of temperature on Brettanomyces bruxellensis: metabolic and kinetic aspects. Can. J. Microbiol. 54, 11–18 (2008)CrossRefGoogle Scholar
  2. M. Butler, Animal Cell Culture & Technology, 1st edn. (BIOS Scientific Publishers, Oxford, 2004), p. 54Google Scholar
  3. Y.A. Cengel, Heat Transfer, 2nd edn. (McGraw-Hill, New York, 2004), pp. 25–27Google Scholar
  4. Y.H. Chang, G.B. Lee, F.C. Huang, Y.Y. Chen, J.L. Lin, Integrated polymerase chain reaction chips utilizing digital microfluidics. Biomed. Microdevices 8, 215–225 (2006)CrossRefGoogle Scholar
  5. P.C. Chen, D.E. Nikitopoullos, S.A. Soper, M.C. Murphy, Temperature distribution effects on micro-CFPCR performance. Biomed. Microdevices 10, 141–152 (2008)CrossRefGoogle Scholar
  6. J.Y. Cheng, M.H. Yen, C.T. Kuo, T.H. Young, A transparent cell-culture microchamber with a variably controlled concentration gradient generator and flow field rectifier. Biomicrofluidics 2, 024105 (2008)CrossRefGoogle Scholar
  7. S.L. Chong, D.G. Mou, A.M. Ali, S.H. Lim, B.T. Tey, Cell growth, cell cycle progress and antibody production in hybridoma cells cultured under mild hypothermic conditions. Hybridoma 27, 107–111 (2008)CrossRefGoogle Scholar
  8. Z.F. Cui, X. Xu, N. Trainor, J.T. Triffitt, J.P. Urban, U.K. Tirlapur, Application of multiple parallel perfused microbioreactors and three-dimensional stem cell culture for toxicity testing. Toxicol. In Vitro 21, 1318–1324 (2007)CrossRefGoogle Scholar
  9. L. De Bartolo, S. Saleron, S. Morelli, L. Giorno, M. Rende, B. Memoli, A. Procino, V.E. Andreucci, A. Bader, E. Drioli, Long-term maintenance of human hepatocytes in oxygen-permeable membrane bioreactor. Biomaterials 27, 4794–4803 (2006)CrossRefGoogle Scholar
  10. J. El-Ali, I.R. Perch-Nielsen, C.R. Poulsen, D.D. Bang, P. Telleman, A. Wolff, Simulation and experimental validation of a SU-8 based PCR thermocycler chip with integrated heaters and temperature sensor. Sens. Actuators A 110, 3–10 (2004)CrossRefGoogle Scholar
  11. R.W. Farndale, D.J. Buttle, A.J. Barrett, Improved quantitation and discrimination of sulphated glycosaminoglycans by use of dimethylmethylene blue. J. Biochim. Biophys. Acta. 883, 173–177 (1986)Google Scholar
  12. A.M. Freyria, M.C. Ronziere, S. Roche, C.F. Rousseau, D. Herbage, Regulation of growth, protein synthesis and maturation of foetal bovine chondrocytes grown in high-density culture in the presence of ascorbic acid, retinoic acid and dihydrocytochalasin B. J. Cell Biochem. 76, 84–98 (1999)CrossRefGoogle Scholar
  13. C.D. Hoemann, J. Sun, V. Chrzanowski, M.D. Buschmann, A multivalent assay to detect glycosaminoglycan, protein, collagen, RNA, DNA content in milligram samples of cartilage or hydrogel-based repair cartilage. Anal. Biochem. 300, 1–10 (2002)CrossRefGoogle Scholar
  14. C.W. Huang, G.B. Lee, A microfluidic system for automatic cell culture. J. Micromech. Microeng. 17, 1266–1274 (2007)CrossRefMathSciNetGoogle Scholar
  15. F.C. Huang, C.S. Liao, G.B. Lee, Integrated microfluidic chips for DNA/RNA amplification. Electrophoresis 27, 3297–3305 (2006)CrossRefGoogle Scholar
  16. H. Kaji, M. Nishizawa, T. Matsue, Localized chemical stimulation to micropatterned cells using multiple laminar fluid flows. Lab Chip 3, 208–211 (2003)CrossRefGoogle Scholar
  17. T. Kraus, E. Verpoorte, V. Linder, W. Franks, A. Hierlemann, F. Heer, S. Hafizovic, T. Fujii, N.F. de Rooij, S. Koster, Characterization of a microfluidic dispensing system for localized stimulation of cellular networks. Lab Chip 6, 218–229 (2006)CrossRefGoogle Scholar
  18. R.B. Lee, J.P.G. Urban, Biochem. Evidence of a negative Pasteur effect in articular cartilage. Biochem. J. 321, 95–102 (1997)Google Scholar
  19. W.C. Lee, K.Y. Lien, G.B. Lee, H.Y. Lei, An integrated microfluidic system using magnetic beads for virus detection. Diagn. Microbiol. Infect. Dis. 60, 51–58 (2008)CrossRefGoogle Scholar
  20. Y.C. Lin, Y. Yamanishi, F. Arai, Proceedings of 2nd IEEE International Conference on Nano/Micro Engineered and Molecular Systems, pp. 659–663 (2007)Google Scholar
  21. Y. Matsubara, Y. Murakami, M. Kobayashi, Y. Morita, E. Tamiya, Application of on-chip cell cultures for the detection of allergic response. Biosens. Bioelectron. 19, 741–747 (2004)CrossRefGoogle Scholar
  22. T.M. Pearce, J.A. Wilson, S.G. Oakes, S.Y. Chiu, J.C. Williams, Integrated microelectrode array and microfluidics for temperature clamp of sensory neurons in culture. Lab Chip 5, 97–101 (2005)CrossRefGoogle Scholar
  23. I.F. Peng, B.A. Berke, Y. Zhu, W.H. Lee, W. Chen, C.F. Wu, Temperature-dependent developmental plasticity of Drosophila neurons: cell-autonomous roles of membrane excitability, Ca+2 flux and cAMP signaling. J. Neurosci. 27, 12611–12622 (2007)CrossRefGoogle Scholar
  24. S.S. Schultz, P.A. Lucas, Human stem cells isolated from adult skeletal muscle differentiate into neural phenotypes. J. Neurosci. Methods 15, 144–155 (2006)CrossRefGoogle Scholar
  25. N. Szita, P. Boccazzi, Z. Zhang, P. Boyle, A.J. Sinskey, K.F. Jensen, Development of a multiplexed microbioreactor system for high-throughput bioprocessing. Lab Chip 5, 819–826 (2005)CrossRefGoogle Scholar
  26. M.H. Wu, J.P.G. Urban, Z. Cui, Z.F. Cui, Development of PDMS microbioreactor with well-defined and homogenous culture environment for chondrocyte 3-D culture. Biomed. Microdevices 8, 331–340 (2006)CrossRefGoogle Scholar
  27. M.H. Wu, J.P.G. Urban, Z.F. Cui, Z. Cui, X. Xu, Effect of extracellular pH on matrix symthesis by chondrocytes in agarose gel. Biotechnol. Prog. 23, 430–434 (2007)CrossRefGoogle Scholar
  28. M.H. Wu, S.B. Huang, Z.F. Cui, Z. Cui, G.B. Lee, Development of perfusion-based micro 3-D cell culture platform and its application for high throughput drug testing. Sens. Actuators B Chem. 129, 231–240 (2008)CrossRefGoogle Scholar
  29. Q. Xiang, B. Xu, R. Fu, D. Li, Real time PCR on disposable PDMS chip with a miniaturized thermal cycler. Biomed. Microdevices 7, 273–279 (2005)CrossRefGoogle Scholar
  30. X. Xu, J.P.G. Urban, U. Tirlapur, M.H. Wu, Z. Cui, Z.F. Cui, Influences of perfusion on metabolism and matrix production by bovine articular chondrocytes in hydrogel scaffolds. Biotechnol. Bioeng. 93, 1103–1111 (2006)CrossRefGoogle Scholar
  31. X. Xu, J.P.G. Urban, J.A. Browning, U. Tirlapur, R.J. Wilkins, M.H. Wu, Z. Cui, Z.F. Cui, Influences of buffer systems on chondrocyte growth during long-term culture in alginate. Osteoarthr. Cartil. 15, 396–402 (2007)CrossRefGoogle Scholar
  32. S.K. Yoon, Y.H. Ahn, M.H. Jeong, Effect of culture temperature on follicle-stimulating hormone production by Chinese hamster ovary cells in a perfusion bioreactor. Appl. Microbiol. Biotechnol. 76, 83–89 (2007)CrossRefGoogle Scholar
  33. K.S. Yun, E. Yoon, Micro/Nanofluidic device for single-cell-based assay. Biomed. Microdevices 7, 35–40 (2005)CrossRefGoogle Scholar

Copyright information

© Springer Science+Business Media, LLC 2010

Authors and Affiliations

  • Jr-Lung Lin
    • 1
  • Min-Hsien Wu
    • 2
  • Chun-Yen Kuo
    • 2
  • Kun-Da Lee
    • 1
  • Ying-Liang Shen
    • 1
  1. 1.Department of Mechanical and Automation EngineeringI-Shou UniversityKaohsiungTaiwan
  2. 2.Graduate Institute of Biochemical and Biomedical EngineeringChang Gung UniversityTaoyuanTaiwan

Personalised recommendations