The next generation of tissue engineered constructs (TECs) requires the incorporation of a controllable and optimized microstructure if they are to chemically, mechanically, and biologically mimic tissue function. In order to obtain TECs with optimized microstructures, a combination of spatiotemporally regulated mechanical and biochemical stimuli is necessary during the formation of the construct. While numerous efforts have been made to create functional tissue constructs, there are few techniques available to stimulate TECs in a localized manner. We herein describe the design of a microdevice which can stimulate TECs in a localized, inhomogeneous, and predefined anisotropic fashion using ferromagnetically doped polydimethylsiloxane microflaps (MFs). Specifically, a sequential magneto-structural finite element model of the proposed microdevice is constructed and utilized to understand how changes in magnetic and geometrical properties of the device affect MF deflection. Our study indicates that a relatively small density of ferromagnetic material is required to result in adequate force and MF defection (175 μm ~7% TEC strain). We also demonstrate that MF to magnet distance is more important than inherent MF magnetic permeability in determining resulting MF deflection. An experimental validation test setup was used to validate the computational solutions. The comparison shows reasonable agreement indicating a 5.9% difference between experimentally measured and computationally predicted MF displacement. Correspondingly, an apparatus with two MFs and two magnets has been made and is currently undergoing construct testing. The current study presents the design of a novel magnetic microactuator for tissue engineering applications. The computational results reported here will form the foundation in the design and optimization of a functional microdevice with multiple MFs and magnets capable of stimulating TECs in nonhomogenous and preferred directions with relevant spatial resolution.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

References

  • M. Eastwood, V.C. Mudera, D.A. McGrouther, R.A. Brown, Effect of precise mechanical loading on fibroblast populated collagen lattices: morphological changes. Cell Motil Cytoskeleton 40(1), 13–21 (1998)

    Article  Google Scholar 

  • K. Kanda, T. Matsuda, Mechanical stress-induced orientation and ultrastructural change of smooth muscle cells cultured in three-dimensional collagen lattices. Cell Transplant 3(6), 481–92 (1994)

    Google Scholar 

  • D. Seliktar, R.A. Black, R.P. Vito, R.M. Nerem, Dynamic mechanical conditioning of collagen-gel blood vessel constructs induces remodeling in vitro. Ann Biomed Eng 28(4), 351–62 (2000)

    Article  Google Scholar 

  • S.W. Liao, K. Hida, J.S. Park, S. Li, Mechanical regulation of matrix reorganization and phenotype of smooth muscle cells and mesenchymal stem cells in 3D matrix. Conf Proc IEEE Eng Med Biol Soc 7, 5024–7 (2004)

    Google Scholar 

  • G.E. Wnek, G.L. Bowlin, Encyclopedia of Biomaterials and Biomedical Engineering. Vol. Tissue Engineering of Skeletal Muscle. Informa Health Care. (2008)

  • N. L'Heureux, S. Paquet, R. Labbe, L. Germain, F.A. Auger, A completely biological tissue-engineered human blood vessel. FASEB J 12(1), 47–56 (1998)

    Google Scholar 

  • J.A. McKee, S.S. Banik, M.J. Boyer, N.M. Hamad, J.H. Lawson, L.E. Niklason, C.M. Counter, Human arteries engineered in vitro. EMBO Rep 4(6), 633–8 (2003)

    Article  Google Scholar 

  • L.E. Niklason, J. Gao, W.M. Abbott, K.K. Hirschi, S. Houser, R. Marini, R. Langer, Functional arteries grown in vitro. Science 284(5413), 489–93 (1999)

    Article  Google Scholar 

  • D.H. Kim, P.K. Wong, J. Park, A. Levchenko, and Y. Sun, Microengineered Platforms for Cell Mechanobiology. Annu Rev Biomed Eng. (2009)

  • D. Armani, Re-configurable fluid circuits by PDMS elastomer micromachining. in Twelfth IEEE International Conference on Micro Electrical Mechanical Systems. (1999)

  • K. Miller, How to test very soft biological tissues in extension? J Biomech 34(5), 651–7 (2001)

    Article  Google Scholar 

  • J.L. Tan, J. Tien, D.M. Pirone, D.S. Gray, K. Bhadriraju, C.S. Chen, Cells lying on a bed of microneedles: an approach to isolate mechanical force. Proc Natl Acad Sci U S A 100(4), 1484–9 (2003)

    Article  Google Scholar 

  • M. Khoo, C. Liu, Micro magnetic silicone elastomer membrane actuator. Sensors and Actuators 89, 259–266 (2001)

    Article  Google Scholar 

  • A. Kretschmer, R. Drake, M. Neidhoefer, M. Wilhelm, Quantification of composition and domain sizes of industrial poly(phthalamide)/poly(dimethylsiloxane) block copolymers using different 1H solid state NMR methods. Solid State Nucl Magn Reson 22(2–3), 204–17 (2002)

    Article  Google Scholar 

  • D. Sadler, T. Liakopoulos, J. Cropp, C. Ahn, T. Henderson, Protopye microvalve using a new magnetic microactuator. SPIE Conference on Microfluidic Devices and Systems 3515, 3515–03 (1998)

    Google Scholar 

  • N.J. Sniadecki, A. Anguelouch, M.T. Yang, C.M. Lamb, Z. Liu, S.B. Kirschner, Y. Liu, D.H. Reich, C.S. Chen, Magnetic microposts as an approach to apply forces to living cells. Proc Natl Acad Sci U S A 104(37), 14553–8 (2007)

    Article  Google Scholar 

  • K&J Magnetics, I. Neodymium Magnet Physical Properties. Available from: http://www.kjmagnetics.com/specs.asp 2007

  • J. Gere, Mechanics of Materials. Sixth Edition ed. Brooks/Cole. 599. (2004)

  • A.E. Brown, Rationale and summary of methods for determining ultrasonic properties of materials at Lawrence Livermore Laboratory. (1995)

  • X. Wang, M. Tillack, S.S. Harilal, 2-D Magnetic circuit analysis for a permanent magnet used in laser ablation plume expansion experiments (University of California, La Jolla, 2003)

    Google Scholar 

  • ANSYS, I., Theory Reference. Canonsburg: ANSYS, Inc. (2006)

  • D. Askeland, The Science and Engineering of Materials. Fourth Edition ed. Thomas-Engineering. (2002)

  • C.A. Lemmon, N.J. Sniadecki, S.A. Ruiz, J.L. Tan, L.H. Romer, C.S. Chen, Shear force at the cell-matrix interface: enhanced analysis for microfabricated post array detectors. Mech Chem Biosyst 2(1), 1–16 (2005)

    Google Scholar 

  • R. Serway, R. Beichner, J.W. Jewett, Physics for Scientists, 5th edn. (Saunders College Publishing, Orlando, 2000)

    Google Scholar 

  • J.H. Ashton, J.P. Vande Geest, B.R. Simon, D.G. Haskett, Compressive mechanical properties of the intraluminal thrombus in abdominal aortic aneurysms and fibrin-based thrombus mimics. J Biomech 42(3), 197–201 (2009)

    Article  Google Scholar 

Download references

Acknowledgements

The authors would like to especially thank Jennifer Watson. Partial funding for this work was provided by an NSF CAREER (0644570) award to JPVG.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jonathan P. Vande Geest.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Keyes, J., Junkin, M., Wong, P.K. et al. Computational simulation of a magnetic microactuator for tissue engineering applications. Biomed Microdevices 11, 1259–1267 (2009). https://doi.org/10.1007/s10544-009-9345-1

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10544-009-9345-1

Keywords

Navigation