Skip to main content
Log in

Study of the Adequacy of a Nonlinear Electric Skin Model

  • Published:
Biomedical Engineering Aims and scope

The adequacy of a nonlinear equivalent circuit for the electrical admittance of the skin was investigated in relation to the type of decomposition and the number of members in a power series approximating the nonlinear conductivity. This work showed that in the case of decompositions of nonlinear components in terms of voltage powers, the response function of the model was adequate for five or more decomposition components, while in the case of decompositions of nonlinear components in terms of test current powers, the response function of the model was inadequate over the whole range of the number of decomposition components studied. These results provide evidence supporting selection of a model for describing the electrical admittance of human skin.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Zimlichman, E., Kanevsky, A., and Shoenfeld, Y., "Diagnosing diseases by measurement of electrical skin resistance: A novel technique," in: IFMBE Proceedings, ICEBI (2007), Vol. 17, pp. 172–176 (2007).

    Article  Google Scholar 

  2. Johnsen, G. K., Martinsen, O. G., and Grimnes, S., "Water gradient and calibration of stratum corneum hydration measurements," in: IFMBE Proceedings, ICEBI (2007), Vol. 17, pp. 158–160 (2007).

    Article  Google Scholar 

  3. Kim, S. et al., "Characteristics of skin impedance for biological active points using dry electrode measurement," in: IFMBE Proceedings, ICEBI (2007), Vol. 17, pp. 177–180 (2007).

    Article  Google Scholar 

  4. Indenbom, V. A. and Chizmadzhev, Yu. A., "Kinetics of current flow through human skin under the action of lowamplitude voltage pulses," Biol. Membr., 18, No. 1, 29–37 (2001).

    CAS  Google Scholar 

  5. Zarnitsin, V. G., Prauzints, M. R., and Chizmadzhev, Yu. A., "Physical methods for the transfer of nucleic acids into tissues and cells," Biol. Membr., 21, No. 5, 355–373 (2004).

    Google Scholar 

  6. Indenbom, V. A., "Activation of the conductivity of the stratum corneum under the action of iontophoretic cell current," Biol. Membr., 19, No. 3, 202–208 (2002).

    CAS  Google Scholar 

  7. Shpunt, V. Kh., "Dynamic electrical properties of human skin," Med. Tekh., No. 4, 38–47 (1997).

  8. Martinsen, O. G., et al., "Memristance in human skin," J. Phys. Conf. Ser., 224, No. 1, 12071 (2010).

  9. Karpukhin, V. A. and Kosorukov, A. E., "Method for identification of nonlinear equivalent circuit parameters of electric admittance of skin," Biomed. Eng., 44, No. 2, 62–65 (2010).

    Article  Google Scholar 

  10. Karpukhin, V. A. and Kosorukov, A. E., "Study of a method for identification of parameters of the nonlinear equivalent circuit of electric admittance of skin," Biomed. Eng., 47, No. 1, 39-42 (2013).

    Article  Google Scholar 

  11. Augambaev, M., Ivanov, A. Z., and Terekhov, Yu. I., Fundamentals of Planning Research Experiments [in Russian], Ukituvchi, Tashkent (1994), pp. 335–336.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. A. Burtsev.

Additional information

Translated from Meditsinskaya Tekhnika, Vol. 57, No. 2, March–April, 2023, pp. 16–19.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Karpukhin, V.A., Kosorukov, A.E., Samorodov, A.V. et al. Study of the Adequacy of a Nonlinear Electric Skin Model. Biomed Eng 57, 97–101 (2023). https://doi.org/10.1007/s10527-023-10277-9

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10527-023-10277-9

Navigation