Skip to main content
Log in

DQE and eDQE of the KARS-BKS2 Digital Slot Scan X-Ray System

  • Published:
Biomedical Engineering Aims and scope

DQE and eDQE were evaluated for a slot scan X-ray system using four standard radiation qualities: RQA3, RQA5, RQA7, and RQA9. The results showed that the system under consideration, KARS-BKS2 fluorograph, provided maximal DQE(u,v) and eDQE(u′,v′) in the case of radiation quality RQA5 and a small focal point. At null spatial frequencies DQE(0) was greater than 40% and eDQE(0) was 35%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Samei, E., Ranger, N. T., MacKenzie, A., Honey, I. D., Dobbins III, J. T., and Ravin, C. E., “Detector or system? Extending the concept of detective quantum efficiency to characterize the performance of digital radiographic imaging systems,” Radiology, 249, No. 3, 926-937 (2008).

  2. “Assessment of digital radiographic detectors and systems using eDQE”, Carl E. Ravin Advanced Imaging Laboratories website: http:deckard.duhs.duke.edu/railabs/radiographicassessment.html (accessed May 25, 2019).

  3. Zelikman, M. I., Kabanov, S. P., and Kruchinin, S. A., “Assessment of effect of radiation scattered in a patient’s body on parameters of digital X-ray image formation channel,” Biomed. Eng., 47, 228-234 (2014).

    Article  Google Scholar 

  4. Samei, E., Ranger, N. T., MacKenzie, A., Honey, I. D., Dobbins III, J. T., and Ravin, C. E., “Effective DQE (eDQE) and speed of digital radiographic systems: An experimental methodology,” Med. Phys., 36, No. 8, 3806-3817 (2009).

    Article  Google Scholar 

  5. Bertolini, M., Nitrosi, A., Rivetti, S., Lanconelli, N., Pattacini, P., Ginocchi, V., and Iori, M., “A comparison of digital radiography systems in terms of effective detective quantum efficiency,” Med. Phys., 39, No. 5, 2617-2627 (2012).

    Article  Google Scholar 

  6. Ranger, N. T., Mackenzie, A., Honey, I. D., Dobbins III, J. T., Ravin, C. E., and Samei, E., “Extension of DQE to include scatter, grid, magnification, and focal spot blur: A new experimental technique and metric,” Proc. SPIE, 7258, 1-12 (2009).

    Google Scholar 

  7. Samei, E., Ranger, N. T., Dobbins, III, J. T., and Ravin, C. E., “Effective dose efficiency: An application-specific metric of quality and dose for digital radiography,” Phys. Med. Biol., 56, No. 16, 5099-5118 (2011).

    Article  Google Scholar 

  8. Yalcin, A. and Olgar, T., “Characterizing the digital radiography system in terms of effective detective quantum efficiency and CDRAD measurement,” Nuclear Instr. Meth. Phys. Res., A 896, 113-121 (2018).

    Article  Google Scholar 

  9. Alves, A. F. F., Alvarez, M., Ribeiro, S. M., Duarte, S. B., Miranda, J. R. A., and Pina, D. R., “Association between subjective evaluation and physical parameters for radiographic images optimization,” Phys. Med., 32, No. 1, 123-132 (2016).

    Article  CAS  Google Scholar 

  10. Clavel, A. H., Monnin, P., Létang, J. M., Verdun, F. R., and Darbon, A., “Characterising the EOS slot-scanning system with the effective detective quantum efficiency,” Rad. Prot. Dos., 169, 319-324 (2016).

    Article  CAS  Google Scholar 

  11. Kabanov, S. P., Studies and Development of Methods for Programmable Systems for Monitoring the Recording Quantum Efficiency of Digital X-Ray Image Receivers [in Russian], Dissertation for Master’s Degree in Technical Sciences (2011).

  12. Bor, D., Guven, A., Yusuf, A. R., Birgul, O., Yuksel, S., Yalcin, A., Marshall, N., and Olgar, T., “A modified formulation of eDQE for digital radiographic imaging,” Rad. Phys. Chem., 156, 6-14 (2019).

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. A. Labusov.

Additional information

Translated from Meditsinskaya Tekhnika, Vol. 55, No. 3, May-Jun., 2021, pp. 39-43.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Bekhterev, A.V., Kotkov, R.V., Labusov, V.A. et al. DQE and eDQE of the KARS-BKS2 Digital Slot Scan X-Ray System. Biomed Eng 55, 204–209 (2021). https://doi.org/10.1007/s10527-021-10103-0

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10527-021-10103-0

Navigation