The ISO method was used to study the X-ray sensitometric characteristics of blue and green screen/film systems for general radiography, including blue-sensitive and orthochromatic films most widely used in Russia. Speed, average gradient, and minimum and maximum density values were compared for films automatically processed using chemicals from three manufacturers.
Similar content being viewed by others
References
Rüdiger, J., Golovkova, S. I., Kavtorova, V. P, et al., “To the applicability of foreign medical radiographic films during various chemophotographic treatments,” Vestn. Rentgenol.Radiol., No. 3, 60-62 (2000).
Golovkova, S. I., Myagkova, M. G., Rüdiger, J., and Shevchenko, V. N., “Parameters of contemporary X-ray films,” All-Russian National Congress of Radiation Diagnosticians and Therapists, ‘Radiology-2011,’ Moscow, May 25-27, 2011, Diagnost. Intervent. Radiol., 5, No. 2, 126-127 (2011).
Golovkova, S. I., Myagkova, M. G., Rüdiger, J., and Shevchenko, V. N., “X-ray sensitometric parameters of common-purpose medical radiographic films,” Vestnik RNTsRR, No. 11 (2011); http://vestnik.rncrr.ru/vestnik/v11/papers/golov_v11.htm (accessed September 24, 2018).
Golovkova, S. I. and Rüdiger, J., “Investigation of chemical kits “RENMED-AUTO” for automatic processing of medical X-ray films,” Vestnik RNTsRR, 1, No.13 (2011); http://vestnik.rncrr.ru/vestnik/v13/papers/rudiger_v13.htm (accessed September 24, 2018).
Golovkova, S. I. and Rüdiger, J., “Changes in sensitometric parameters of medical X-Ray films. Part 1: Evaluation using automatic processing,” Biomed. Eng., 47, No. 5, 264-267 (2014).
OST 6-17-54–80. Monochrome Photographic Materials on Transparent Substrate. Method of X-ray Sensitometric Testing of Films for Radiography and Fluorography [in Russian].
GOST ISO 9236-1–2011. Sensitometry of screen/film systems for medical radiography. Part 1. Determination of sensitometric curve shape, speed and average gradient [in Russian].
Golovkova, S. I. and Rüdiger, J., “Comparison of two methods of X-ray sensitometry,” Vestnik RNTsRR, 15, No. 3 (2015); http://vestnik.rncrr.ru/vestnik/v15/papers/golovkova_v15-3.htm (accessed September 24, 2018).
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Meditsinskaya Tekhnika, Vol. 53, No. 4, Jul.-Aug., 2019, pp. 26-28.
Rights and permissions
About this article
Cite this article
Golovkova, S.I., Rüdiger, J. X-Ray Sensitometric Characteristics of Systems for General Radiography with Automatic Film Processing Using Various Chemicals. Biomed Eng 53, 262–265 (2019). https://doi.org/10.1007/s10527-019-09922-z
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10527-019-09922-z