X-Ray Sensitometric Characteristics of Systems for General Radiography with Automatic Film Processing Using Various Chemicals

  • Published:
Biomedical Engineering Aims and scope

The ISO method was used to study the X-ray sensitometric characteristics of blue and green screen/film systems for general radiography, including blue-sensitive and orthochromatic films most widely used in Russia. Speed, average gradient, and minimum and maximum density values were compared for films automatically processed using chemicals from three manufacturers.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Rüdiger, J., Golovkova, S. I., Kavtorova, V. P, et al., “To the applicability of foreign medical radiographic films during various chemophotographic treatments,” Vestn. Rentgenol.Radiol., No. 3, 60-62 (2000).

  2. Golovkova, S. I., Myagkova, M. G., Rüdiger, J., and Shevchenko, V. N., “Parameters of contemporary X-ray films,” All-Russian National Congress of Radiation Diagnosticians and Therapists, ‘Radiology-2011,’ Moscow, May 25-27, 2011, Diagnost. Intervent. Radiol., 5, No. 2, 126-127 (2011).

  3. Golovkova, S. I., Myagkova, M. G., Rüdiger, J., and Shevchenko, V. N., “X-ray sensitometric parameters of common-purpose medical radiographic films,” Vestnik RNTsRR, No. 11 (2011); http://vestnik.rncrr.ru/vestnik/v11/papers/golov_v11.htm (accessed September 24, 2018).

  4. Golovkova, S. I. and Rüdiger, J., “Investigation of chemical kits “RENMED-AUTO” for automatic processing of medical X-ray films,” Vestnik RNTsRR, 1, No.13 (2011); http://vestnik.rncrr.ru/vestnik/v13/papers/rudiger_v13.htm (accessed September 24, 2018).

  5. Golovkova, S. I. and Rüdiger, J., “Changes in sensitometric parameters of medical X-Ray films. Part 1: Evaluation using automatic processing,” Biomed. Eng., 47, No. 5, 264-267 (2014).

    Article  Google Scholar 

  6. OST 6-17-54–80. Monochrome Photographic Materials on Transparent Substrate. Method of X-ray Sensitometric Testing of Films for Radiography and Fluorography [in Russian].

  7. GOST ISO 9236-1–2011. Sensitometry of screen/film systems for medical radiography. Part 1. Determination of sensitometric curve shape, speed and average gradient [in Russian].

  8. Golovkova, S. I. and Rüdiger, J., “Comparison of two methods of X-ray sensitometry,” Vestnik RNTsRR, 15, No. 3 (2015); http://vestnik.rncrr.ru/vestnik/v15/papers/golovkova_v15-3.htm (accessed September 24, 2018).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. Rüdiger.

Additional information

Translated from Meditsinskaya Tekhnika, Vol. 53, No. 4, Jul.-Aug., 2019, pp. 26-28.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Golovkova, S.I., Rüdiger, J. X-Ray Sensitometric Characteristics of Systems for General Radiography with Automatic Film Processing Using Various Chemicals. Biomed Eng 53, 262–265 (2019). https://doi.org/10.1007/s10527-019-09922-z

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10527-019-09922-z

Navigation