Advertisement

Biomedical Engineering

, Volume 51, Issue 6, pp 449–452 | Cite as

Effect of Antenna Shape on Wireless Data Channel Bandwidth in Batteryless Implants

  • R. R. Aubakirov
  • A. A. Danilov
Article
  • 15 Downloads

The effect of the shapes of the transmitter and receiver antennas on the voltage gain and the bandwidth of the wireless channel of inductive powering units was evaluated. Antennas with square and round coils were compared. It was shown that under otherwise identical conditions square-coil antennas provided higher voltage gain and broader bandwidth of the wireless channel.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Amar, A. B., Kouki, A. B., and Cao, H., “Power approaches for implantable medical devices sensors,” 15, No. 11, 28889-28914 (2015).Google Scholar
  2. 2.
    Agarwal, K., Jegadeesan, R., Guo, Y. X., and Thakor, N. V., “Wireless power transfer strategies for implantable bioelectronics: Methodological review,” IEEE Rev. Biomed. Eng., in press.Google Scholar
  3. 3.
    Nopper, R., Has, R., and Reindl, L., “A wireless sensor readout system – circuit concept, simulation, and accuracy,” IEEE Trans. Instr. Meas., 60, No. 8, 1-8 (2011).CrossRefGoogle Scholar
  4. 4.
    RamRakhyani, A. K., “On the design of efficient multi-coil telemetry system for biomedical implants,” IEEE Trans. Biomed. Circ. Sys., 7, No. 1, 11-23 (2012).CrossRefGoogle Scholar
  5. 5.
    Galbraith, D. C., Soma, M., and White, R. L., “A wide-band efficient inductive transdermal power and data link with coupling insensitive gain,” IEEE Trans. Biomed. Eng., 34, No. 4, 265-275 (1987).CrossRefGoogle Scholar
  6. 6.
    Bosshard, R., Mühlethaler, J., Kolar, J. W., and Stevanović, I., “Optimized magnetic design for inductive power transfer coils,” in: 28th IEEE APEC (2013), pp. 1812-1819.Google Scholar
  7. 7.
    Zierhofer, C. M. and Hochmair, E. S., “Geometric approach for coupling enhancement of magnetically coupled coils,” IEEE Trans. Biomed. Eng., 43, No. 7, 704-714 (1996).CrossRefGoogle Scholar
  8. 8.
    Danilov, A. A., Mindubaev, E. A., and Selishchev, S. V., “Design and evaluation of an inductive powering unit for implantable medical devices using GPU computing,” Progr. Electromagn. Res. B, 69, 61-73 (2016).CrossRefGoogle Scholar
  9. 9.
    Jow, U. and Ghovanloo, M., “Design and optimization of printed spiral coils for efficient transcutaneous inductive power transmission,” IEEE Trans. Biomed. Circ. Sys., 1, No. 3, 193-202 (2007).CrossRefGoogle Scholar
  10. 10.
    McDonough, M. and Fahimi, B., Comparison between circular and square coils for use in Wireless Power Transmission, in: CEM (2014), pp. 1-2.Google Scholar
  11. 11.
    Ezhil, R. J., Ankit, D., and Praveen, K., “Accurate computation of mutual inductance of two air core square coils with lateral and angular misalignments in a flat planar surface,” IEEE Trans. Magnet., 50, No. 1, 1-9 (2014).Google Scholar
  12. 12.
    Aubakirov, R. R., “Numerical simulation of inductive transcutaneous wireless energy transfer using square coils,” in: Microelectronics and Informatics 2017 Collection [in Russian], (2017), pp. 8-13.Google Scholar
  13. 13.
    Danilov, A. A. and Mindubaev, E. A., “ Influence of angular coil displacements on effectiveness of wireless transcutaneous inductive energy transmission,” Med. Tekh., No. 3, 33-35 (2015).Google Scholar

Copyright information

© Springer Science+Business Media, LLC, part of Springer Nature 2018

Authors and Affiliations

  1. 1.AO ZITC, ZelenogradMoscowRussia

Personalised recommendations