Effect of Elasticity of Tubes of the Hydraulic Pressure Simulator on Results of Calibration of Noninvasive Sphygmomanometers

  • Published:
Biomedical Engineering Aims and scope

The elasticity coefficient of tubes of a hydraulic pressure simulator used for complex automatic calibration of noninvasive sphygmomanometers was experimentally studied. The Frank and Roston models were used to test the effect of the elasticity of tubes of the hydraulic pressure simulator on the results of the calibration of the sphygmomanometers.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. R. N. Karataev, A. I. Soyko, I. N. Sinitsyn, et al., “A Device for Verification of Automated Sphygmomanometers”, RF Patent No. 2393758.

  2. A. I. Soyko and R. N. Karataev, Calibration Devices for Arterial Pressure Meters Based on Pulsed Flow Generation [in Russian], Otechestvo, Kazan (2009).

    Google Scholar 

  3. R. N. Karataev, A. I. Soyko, I. N. Sinitsyn, F. M. Galimov, et al., “A Human Hand Model for Verification of Arterial Pressure and Heart Rate Meters”, RF Patent No. 2405423.

  4. O. Frank, Z. Biol., No. 37, 483-526 (1899).

  5. O. Frank, Z. Biol., No. 85, 91-130 (1927).

  6. O. Frank, Z. Biol., No. 88, 249 (1928).

  7. N. Rashevsky, Some Medical Aspects of Mathematical Biology [Russian translation], Meditsina, Moscow (1966).

    Google Scholar 

  8. S. Roston, Bull. Math. Biophys., No. 24, 129-135 (1962).

  9. S. Roston and L. Leight, J. Clin. Invent., No. 38, 777-783 (1959).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. I. Soyko.

Additional information

Translated from Meditsinskaya Tekhnika, Vol. 48, No. 4, Jul.-Aug., 2014, pp. 11-14.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Soyko, A.I., Karataev, R.N. & Chrunina, A.I. Effect of Elasticity of Tubes of the Hydraulic Pressure Simulator on Results of Calibration of Noninvasive Sphygmomanometers. Biomed Eng 48, 182–186 (2014). https://doi.org/10.1007/s10527-014-9448-8

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10527-014-9448-8

Keywords

Navigation