Skip to main content
Log in

Collapse shake-table testing of a clay-URM building with chimneys

  • Original Research
  • Published:
Bulletin of Earthquake Engineering Aims and scope Submit manuscript

Abstract

This paper discusses the results of a unidirectional shake-table test carried out on a full-scale unreinforced clay-brick masonry building with chimneys. The specimen embodied construction details representative of old detached single-storey houses of the Groningen province in the Netherlands, without any specific seismic-resistant detailing. The house featured a typical Dutch gambrel roof that allowed for living space above the attic floor, with high gables that were vulnerable to out-of-plane excitation. The floor consisted of timber joists and planks, resulting in a flexible diaphragm. Two clay-brick chimneys were included to investigate the performance of falling non-structural masonry elements in earthquakes. A cumulative incremental dynamic test was performed up to collapse conditions, using input ground motions compatible with induced seismicity scenarios for the examined region. The paper summarises the key characteristics of the specimen and the observations from the shake-table tests, illustrating the evolution of the structural and non-structural damage, and the dynamic response of the building. The attainment of significant damage limit states is correlated with experimentally defined engineering demand parameters and ground-motion intensity measures for the performance-based seismic assessment of unreinforced masonry buildings. All data from the tests are available upon request on www.eucentre.it/nam-project.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
Fig. 20
Fig. 21
Fig. 22
Fig. 23
Fig. 24
Fig. 25
Fig. 26
Fig. 27

Similar content being viewed by others

References

  • Arias A (1970) A measure of earthquake intensity. In: Hansen RJ (ed) Seismic design of nuclear power plants, 1st edn. MIT Press, Cambridge, pp 438–483

    Google Scholar 

  • Baggio C, Bernardini A, Colozza R, Corazza L, Della Bella M, Di Pasquale G, Dolce M, Goretti A, Martinelli A, Orsini G, Papa F, Zuccaro G (2007) Field manual for post-earthquake damage and safety assessment and short term countermeasures (AeDES). JRC research report EUR 22868 EN, European Commission, Joint Research Centre, Institute for the Protection and Security of the Citizen, Luxemburg

  • Bianchini M, Diotallevi P, Baker JW (2009) Prediction of inelastic structural response using an average of spectral accelerations. In: Proceedings of the 10th international conference on structural safety and reliability (ICOSSAR09), Osaka

  • Bommer JJ, Martinez-Pereira A (1999) The effective duration of earthquake strong motion. J Earthq Eng 3(2):127–172. https://doi.org/10.1080/13632469909350343

    Article  Google Scholar 

  • Bommer JJ, Crowley H, Pinho R (2015a) A risk-mitigation approach to the management of induced seismicity. J Seismol 19(2):623–646. https://doi.org/10.1007/s10950-015-9478-z

    Article  Google Scholar 

  • Bommer JJ, Crowley H, Pinho R, Polidoro B (2015b) Selection of acceleration time-series for shake table testing of Groningen masonry building at the EUCENTRE, Pavia. Report on Groningen field seismic hazard and risk assessment project, EUCENTRE, Pavia

  • Bourne SJ, Oates SJ, Bommer JJ, Dost B, Van Elk J, Doornhof D (2015) A Monte Carlo method for probabilistic hazard assessment of induced seismicity due to conventional natural gas production. Bull Seismol Soc Am 105(3):1721–1738. https://doi.org/10.1785/0120140302

    Article  Google Scholar 

  • Brown D (2018) Tracker 5.0: video analysis and modelling tool. Open source physics. https://physlets.org/tracker. Accessed 12 Oct 2019

  • Calvi GM (1999) A displacement-based approach for vulnerability evaluation of classes of buildings. J Earthq Eng 3(3):411–438. https://doi.org/10.1142/S136324699900017X

    Article  Google Scholar 

  • Casapulla C, Portioli F (2016) Experimental tests on the limit states of dry-jointed tuff blocks. Mater Struct 49(3):751–767. https://doi.org/10.1617/s11527-015-0536-3

    Article  Google Scholar 

  • Correia AA, Tomassetti U, Campos AC, Penna A, Magenes G, Graziotti F (2018) Collapse shake-table test on a URM-timber roof substructure. In: Proceedings of the 16th European conference on earthquake engineering (ECEE), Thessaloniki

  • Crowley H, Polidoro B, Pinho R, Van Elk J (2017) Framework for developing fragility and consequence models for local personal risk. Earthq Spectra 33(4):1325–1345. https://doi.org/10.1193/083116EQS140M

    Article  Google Scholar 

  • Crowley H, Pinho R, Cavalieri F (2019a) Report on the v6 fragility and consequence models for the Groningen field. Report on Groningen field seismic hazard and risk assessment project, Pavia. https://www.nam.nl/feiten-en-cijfers. Accessed 12 Oct 2019

  • Crowley H, Pinho R, Van Elk J, Uilenreef J (2019b) Probabilistic damage assessment of buildings due to induced seismicity. Bull Earthq Eng 17(8):4495–4516. https://doi.org/10.1007/s10518-018-0462-1

    Article  Google Scholar 

  • Dost B, Kraaijpoel D (2013) The August 16, 2012 earthquake near Huizinge (Groningen). KNMI technical report, Royal Netherlands Meteorological Institute, De Bilt. http://bibliotheek.knmi.nl. Accessed 12 Oct 2019

  • Dost B, Goutbeek T, Van Eck T, Kraaijpoel D (2012) Monitoring induced seismicity in the North of the Netherlands: status report 2010. KNMI scientific report WR 2012-2013, Royal Netherlands Meteorological Institute, De Bilt

  • Drosos V, Anastasopoulos I (2014) Shaking table testing of multidrum columns and portals. Earthq Eng Struct Dyn 43(11):1703–1723. https://doi.org/10.1002/eqe.2418

    Article  Google Scholar 

  • Electrical Power Research Institute (EPRI) (1988) A criterion for determining exceedance of the operating basis earthquake. EPRI report NP-5930, Electrical Power Research Institute, Palo Alto

  • Esposito R, Messali F, Ravenshorst GJP, Schipper HR, Rots JG (2019) Seismic assessment of a lab-tested two-storey unreinforced masonry Dutch terraced house. Bull Earthq Eng 17(8):4601–4623. https://doi.org/10.1007/s10518-019-00572-w

    Article  Google Scholar 

  • European Committee for Standardization (CEN) (1998) EN 1052-1: methods of test for masonry—part 1: determination of compressive strength. European Committee for Standardization, Brussels

    Google Scholar 

  • European Committee for Standardization (CEN) (1999a) EN 1015-11: methods of test for mortar for masonry—part 11: determination of flexural and compressive strength of hardened mortar. European Committee for Standardization, Brussels

    Google Scholar 

  • European Committee for Standardization (CEN) (1999b) EN 1052-2: methods of test for masonry—part 2: determination of flexural strength. European Committee for Standardization, Brussels

    Google Scholar 

  • European Committee for Standardization (CEN) (2002) EN 1052-3: methods of test for masonry—part 3: determination of initial shear strength. European Committee for Standardization, Brussels

    Google Scholar 

  • European Committee for Standardization (CEN) (2005) EN 1052-5: methods of test for masonry—part 5: determination of bond strength by the bond wrench method. European Committee for Standardization, Brussels

    Google Scholar 

  • European Committee for Standardization (CEN) (2011) EN 772-1: methods of test for masonry units—part 1: determination of compressive strength. European Committee for Standardization, Brussels

    Google Scholar 

  • Giaretton M, Ingham JM, Dizhur D (2017) Experimental validation of seismic retrofit solutions for URM chimneys. Bull Earthq Eng 16(1):295–313. https://doi.org/10.1007/s10518-017-0200-0

    Article  Google Scholar 

  • Giaretton M, Dizhur D, Ingham JM (2018) Shake table testing of seismically restrained clay-brick masonry parapets. Earthq Spectra 34(1):99–119. https://doi.org/10.1193/040716EQS054M

    Article  Google Scholar 

  • Graziotti F, Rossi A, Mandirola M, Penna A, Magenes G (2016a) Experimental characterisation of calcium-silicate brick masonry for seismic assessment. In: Brick and block masonry and proceedings of the 16th international brick and block masonry conference (IBMAC), Padova. https://doi.org/10.1201/b21889-215

    Chapter  Google Scholar 

  • Graziotti F, Tomassetti U, Penna A, Magenes G (2016b) Out-of-plane shaking table tests on URM single leaf and cavity walls. Eng Struct 125:455–470. https://doi.org/10.1016/j.engstruct.2016.07.011

    Article  Google Scholar 

  • Graziotti F, Tomassetti U, Kallioras S, Penna A, Magenes G (2017) Shaking table test on a full-scale URM cavity wall building. Bull Earthq Eng 15(12):5329–5364. https://doi.org/10.1007/s10518-017-0185-8

    Article  Google Scholar 

  • Graziotti F, Penna A, Magenes G (2019a) A comprehensive in situ and laboratory testing programme supporting seismic risk analysis of URM buildings subjected to induced earthquakes. Bull Earthq Eng 17(8):4575–4599. https://doi.org/10.1007/s10518-018-0478-6

    Article  Google Scholar 

  • Graziotti F, Tomassetti U, Sharma S, Grottoli L, Magenes G (2019b) Experimental response of URM single leaf and cavity walls in out-of-plane two-way bending generated by seismic excitation. Constr Build Mater 195(20):650–670. https://doi.org/10.1016/j.conbuildmat.2018.10.076

    Article  Google Scholar 

  • Grünthal G (ed) (1998) European macroseismic scale 1998 (EMS-98). Cahiers du Centre Européen de Géodynamique et de Séismologie 15. Centre Européen de Géodynamique et de Séismologie, Luxembourg

  • Housner GW (1952) Intensity of ground motion during strong earthquakes. Caltech technical report, California Institute of Technology, Pasadena. http://authors.library.caltech.edu. Accessed 12 Oct 2019

  • Kallioras S, Guerrini G, Tomassetti U, Marchesi B, Penna A, Graziotti F, Magenes G (2018a) Experimental seismic performance of a full-scale unreinforced clay-masonry building with flexible timber diaphragms. Eng Struct 161:231–249. https://doi.org/10.1016/j.engstruct.2018.02.016

    Article  Google Scholar 

  • Kallioras S, Correia AA, Marques A, Bernardo V, Candeias PX, Graziotti F (2018b) LNEC-BUILD-3: experimental investigation of the seismic response of a Dutch detached URM house with chimneys. EUCENTRE technical report EUC203/2018U, EUCENTRE, Pavia. http://www.eucentre.it/nam-project. Accessed 12 Oct 2019

  • Kallioras S, Correia AA, Candeias PX, Campos AC, Graziotti F (2019) Dataset from the dynamic shake-table tests of a full-scale unreinforced clay-masonry building with chimneys. Submitted for publication in data in brief

  • Kempton JJ, Stewart JP (2006) Prediction equations for significant duration of earthquake ground motions considering site and near-source effects. Earthq Spectra 22(4):985–1013. https://doi.org/10.1193/1.2358175

    Article  Google Scholar 

  • Kounadis AN (2015) New findings in the rocking instability of one and two rigid block systems under ground motion. Meccanica 50(9):2219–2238. https://doi.org/10.1007/s11012-015-0167-3

    Article  Google Scholar 

  • Lagomarsino S, Cattari S (2015) PERPETUATE guidelines for seismic performance-based assessment of cultural heritage masonry structures. Bull Earthq Eng 13(1):13–47. https://doi.org/10.1007/s10518-014-9674-1

    Article  Google Scholar 

  • Magenes G, Penna A, Senaldi IE, Rota M, Galasco A (2014) Shaking table test of a strengthened full-scale stone masonry building with flexible diaphragms. Int J Archit Herit Conserv Anal Restor 8(3):349–375. https://doi.org/10.1080/15583058.2013.826299

    Article  Google Scholar 

  • Ministry of Infrastructures and Transport (MIT) (2018) Norme tecniche per le costruzioni (NTC18). Decreto Ministeriale del 17 gennaio 2018, Supplemento ordinario n. 8 alla Gazzetta Ufficiale n. 42 del 20 febbraio 2018, Ministry of Infrastructures and Transport, Rome (in Italian)

  • Netherlands Standardization Institute (NEN) (2018) Assessment of structural safety of buildings in case of erection, reconstruction, and disapproval—basic rules for seismic actions: induced earthquakes (NPR 9998). Netherlands Standardization Institute, Delft (in Dutch). The code response spectra are available at http://seismischekrachten.nen.nl/webtool.php. Accessed 12 Oct 2019

  • Pinho R, Malomo D, Brunesi E (2017) Nonlinear dynamic analysis of index buildings for v5 fragility and consequence models. Report on the v5 fragility and consequence models for the Groningen Field, Mosayk, Pavia. https://www.nam.nl/feiten-en-cijfers. Accessed 12 Oct 2019

  • Rots JG, Messali F, Esposito R, Mariani V, Jafari S (2017) Multi-scale approach towards Groningen masonry and induced seismicity. Key Eng Mater 747:653–661. https://doi.org/10.4028/www.scientific.net/KEM.747.653

    Article  Google Scholar 

  • Tomassetti U, Correia AA, Candeias PX, Graziotti F, Campos Costa A (2019) Two-way bending out-of-plane collapse of a full-scale URM building tested on a shake-table. Bull Earthq Eng 17(4):2165–2198. https://doi.org/10.1007/s10518-018-0507-5

    Article  Google Scholar 

  • Tondelli M, Graziotti F, Rossi A, Magenes G (2015) Characterization of masonry materials in the Groningen area by means of in situ and laboratory testing. EUCENTRE technical report, EUCENTRE, Pavia. http://www.eucentre.it/nam-project. Accessed 12 Oct 2019

  • Vaculik J, Griffith MC (2018) Out-of-plane shaketable testing of unreinforced masonry walls in two-way bending. Bull Earthq Eng 16(7):2839–2876. https://doi.org/10.1007/s10518-017-0282-8

    Article  Google Scholar 

  • Van Elk J, Bourne SJ, Oates SJ, Bommer JJ, Pinho R, Crowley H (2019) A probabilistic model to evaluate options for mitigating induced seismic risk. Earthq Spectra 35(2):537–564. https://doi.org/10.1193/050918EQS118M

    Article  Google Scholar 

  • Zapico BB, Tondelli M, Jafari S, Graziotti F, Millekamp H, Rots J, Palmieri M (2018) A masonry catalogue for the Groningen region. In: Proceedings of the 16th European conference on earthquake engineering (ECEE), Thessaloniki

Download references

Acknowledgements

This work is part of the EUCENTRE Project “Study of the vulnerability of masonry buildings in Groningen”, within the research framework programme on hazard and risk of induced seismicity in the Groningen province, sponsored by the Nederlandse Aardolie Maatschappij BV (NAM). The authors would like to thank all parties involved in this Project: the Dutch construction team of Ronda BV and the local Portuguese carpenters for their diligent work and enthusiasm in building the test house; the technical staff of the Earthquake Engineering and Structural Dynamics Unit of LNEC, who performed the tests; and partners NAM, Arup, and TU Delft for their insight and contributions related to the shake-table test programme. The valuable advice of R. Pinho was essential to the Project and is gratefully acknowledged. Thanks also go to J. Uilenreef, J. Klement-Kroezen, P. X. Candeias, A.I. Marques, V. Bernardo, and L. Grottoli for the practical support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Francesco Graziotti.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kallioras, S., Correia, A.A., Graziotti, F. et al. Collapse shake-table testing of a clay-URM building with chimneys. Bull Earthquake Eng 18, 1009–1048 (2020). https://doi.org/10.1007/s10518-019-00730-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10518-019-00730-0

Keywords

Navigation