Abstract
Precast segmental column has been developed in recent years as one of the widely used prefabricated structures to accelerate construction speed. However, its applications are limited in the areas of low seismicity due to insufficient knowledge about its performance under seismic loading. Recently, some research works have been performed to understand the seismic performance of precast segmental columns. However, only the uniaxial cyclic loading was considered. In reality, the seismic excitation is not uniaxial. Considering responses of columns to uniaxial loading only may not accurately reflect the true structural response during an earthquake. In this study, comprehensive numerical analyses are carried out to investigate the seismic performances of circular precast segmental columns under biaxial lateral cyclic loadings. A three-dimensional numerical model is firstly developed and validated against the experimental results of a precast concrete-filled tube segmental column under uniaxial cyclic loading. Six biaxial cyclic loading cases are then applied to the validated model. The numerical results indicate that biaxial cyclic loading paths can significantly influence the strength, ductility and energy dissipation of the column. In addition, the residual displacement of the segmental column increases obviously under biaxial cyclic loading compared with that of the column under uniaxial cyclic loading. Shape memory alloy is found to be effective to minimize the residual displacement of the segmental column under biaxial loading. Moreover, the axial loading ratio has a more pronounced effect on the strength degradations of the column under biaxial lateral cyclic loading than that of the column under uniaxial loading.
Similar content being viewed by others
References
Auricchio F, Taylor RL, Lubliner J (1997) Shape-memory alloys: macromodelling and numerical simulations of the superelastic behavior. Comput Methods Appl Mech Eng 146:281–312
Billington SL, Yoon J (2004) Cyclic response of unbonded posttensioned precast columns with ductile fiber-reinforced concrete. J Bridge Eng 9:353–363
Bousias SN, Verzeletti G, Fardis MN, Gutierrez E (1995) Load-path effects in column biaxial bending with axial force. J Eng Mech 121:596–605
Bu ZY, Ou YC, Song JW, Zhang NS, Lee GC (2015) Cyclic loading test of unbonded and bonded posttensioned precast segmental bridge columns with circular section. J Bridge Eng 21:04015043
Cai Z-K, Wang Z, Yang TY (2018a) Experimental testing and modeling of precast segmental bridge columns with hybrid normal- and high-strength steel rebars. Constr Build Mater 166:945–955. https://doi.org/10.1016/j.conbuildmat.2018.01.159
Cai Z-K, Zhou Z, Wang Z (2018b) Influencing factors of residual drifts of precast segmental bridge columns with energy dissipation bars. Adv Struct Eng. https://doi.org/10.1177/1369433218780545
Chang S-Y (2009) Experimental studies of reinforced concrete bridge columns under axial load plus biaxial bending. J Struct Eng 136:12–25
Chou CC, Chen YC (2006) Cyclic tests of post-tensioned precast CFT segmental bridge columns with unbonded strands. Earthq Eng Struct Dyn 35:159–175
Chou CC, Chang HJ, Hewes JT (2013) Two-plastic-hinge and two dimensional finite element models for post-tensioned precast concrete segmental bridge columns. Eng Struct 46:205–217
Dawood H, ElGawady M, Hewes J (2011) Behavior of segmental precast posttensioned bridge piers under lateral loads. J Bridge Eng 17:735–746
ElGawady MA, Sha’lan A (2010) Seismic behavior of self-centering precast segmental bridge bents. J Bridge Eng 16:328–339
ElGawady M, Booker AJ, Dawood HM (2010) Seismic behavior of posttensioned concrete-filled fiber tubes. J Compos Constr 14:616–628
Goto Y, Jiang K, Obata M (2006) Stability and ductility of thin-walled circular steel columns under cyclic bidirectional loading. J Struct Eng 132:1621–1631. https://doi.org/10.1061/(ASCE)0733-9445(2006)132:10(1621)
Goto Y, Muraki M, Obata M (2009) Ultimate state of thin-walled circular steel columns under bidirectional seismic accelerations. J Struct Eng 135:1481–1490
Han L-H, Yao G-H, Tao Z (2007) Performance of concrete-filled thin-walled steel tubes under pure torsion Thin Wall Struct 45:24–36
Hewes JT, Priestley MN (2002) Seismic design and performance of precast concrete segmental bridge columns, vol no. SSRP-2001/25. University of California, San Diego
Khaled A, Massicotte B, Tremblay R (2010) Cyclic testing of large-scale rectangular bridge columns under bidirectional earthquake components. J Bridge Eng 16:351–363
Leitner EJ, Hao H (2016) Three-dimensional finite element modelling of rocking bridge piers under cyclic loading and exploration of options for increased energy dissipation. Eng Struct 118:74–88. https://doi.org/10.1016/j.engstruct.2016.03.042
Li C, Hao H, Bi K (2017a) Numerical study on the seismic performance of precast segmental concrete columns under cyclic loading. Eng Struct 148:373–386. https://doi.org/10.1016/j.engstruct.2017.06.062
Li C, Hao H, Zhang X, Bi K (2017b) Experimental study of precast segmental columns with unbonded tendons under cyclic loading. Adv Struct Eng. https://doi.org/10.1177/1369433217717119
Nikbakht E, Rashid K, Hejazi F, Osman SA (2014) A numerical study on seismic response of self-centring precast segmental columns at different post-tensioning forces. Lat Am J Solids Struct 11:864–883
Nikbakht E, Rashid K, Hejazi F, Osman SA (2015) Application of shape memory alloy bars in self-centring precast segmental columns as seismic resistance. Struct Infrastruct Eng 11:297–309
Ou YC, Wang PH, Tsai MS, Chang KC, Lee GC (2009) Large-scale experimental study of precast segmental unbonded posttensioned concrete bridge columns for seismic regions. J Struct Eng 136:255–264
Ou YC, Tsai MS, Chang KC, Lee GC (2010) Cyclic behavior of precast segmental concrete bridge columns with high performance or conventional steel reinforcing bars as energy dissipation bars. Earthq Eng Struct Dyn 39:1181–1198
Qiu F, Li W, Pan P, Qian J (2002) Experimental tests on reinforced concrete columns under biaxial quasi-static loading. Eng Struct 24:419–428
Rodrigues H, Varum H, Arêde A, Costa A (2012) A comparative analysis of energy dissipation and equivalent viscous damping of RC columns subjected to uniaxial and biaxial loading. Eng Struct 35:149–164. https://doi.org/10.1016/j.engstruct.2011.11.014
Rodrigues H, Arêde A, Varum H, Costa A (2013a) Damage evolution in reinforced concrete columns subjected to biaxial loading. Bull Earthq Eng 11:1517–1540
Rodrigues H, Arêde A, Varum H, Costa AG (2013b) Experimental evaluation of rectangular reinforced concrete column behaviour under biaxial cyclic loading. Earthq Eng Struct Dyn 42:239–259. https://doi.org/10.1002/eqe.2205
Rodrigues H, Arêde A, Furtado A, Rocha P (2015a) Seismic behavior of strengthened RC columns under biaxial loading: an experimental characterization. Constr Build Mater 95:393–405. https://doi.org/10.1016/j.conbuildmat.2015.07.149
Rodrigues H, Furtado A, Arêde A (2015b) Behavior of rectangular reinforced-concrete columns under biaxial cyclic loading and variable axial loads. J Struct Eng 142:04015085
Rodrigues H, Furtado A, Arêde A (2017) Experimental evaluation of energy dissipation and viscous damping of repaired and strengthened RC columns with CFRP jacketing under biaxial load. Eng Struct 145:162–175. https://doi.org/10.1016/j.engstruct.2017.05.021
Rodrigues H, Furtado A, Arêde A, Vila-Pouca N, Varum H (2018) Experimental study of repaired RC columns subjected to uniaxial and biaxial horizontal loading and variable axial load with longitudinal reinforcement welded steel bars solutions. Eng Struct 155:371–386. https://doi.org/10.1016/j.engstruct.2017.11.043
Saiidi MS, O’Brien M, Sadrossadat-Zadeh M (2009) Cyclic response of concrete bridge columns using superelastic nitinol and bendable concrete. ACI Struct J 106:69
Shim CS, Chung C-H, Kim HH (2008) Experimental evaluation of seismic performance of precast segmental bridge piers with a circular solid section. Eng Struct 30:3782–3792
Shirmohammadi F, Esmaeily A (2015) Performance of reinforced concrete columns under bi-axial lateral force/displacement and axial load. Eng Struct 99:63–77. https://doi.org/10.1016/j.engstruct.2015.04.042
Shrestha B, Hao H (2015) Parametric study of seismic performance of super-elastic shape memory alloy-reinforced bridge piers. Struct Infrastruct Eng 12:1076–1089. https://doi.org/10.1080/15732479.2015.1076856
Sideris P, Aref AJ, Filiatrault A (2014) Quasi-static cyclic testing of a large-scale hybrid sliding-rocking segmental column with slip-dominant joints. J Bridge Eng 19:04014036
Simulia DS (2012) Abaqus 6.12 documentation Providence, Rhode Island
Sun Z, Wang D, Bi K, Si B (2016) Experimental and numerical investigations on the seismic behavior of bridge piers with vertical unbonded prestressing strands. Bull Earthq Eng 14:501–527
Ucak A, Tsopelas P (2014) Load path effects in circular steel columns under bidirectional lateral cyclic loading. J Struct Eng 141:04014133
Wilson JC, Wesolowsky MJ (2005) Shape memory alloys for seismic response modification: a state-of-the-art review. Earthq Spect 21:569–601. https://doi.org/10.1193/1.1897384
Acknowledgements
The authors would like to acknowledge the financial support from Australian Research Council (DP 150104346) to carry out this research work. The first author would also like to acknowledge Curtin University and China Scholarship Council for providing the scholarship.
Author information
Authors and Affiliations
Corresponding authors
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Rights and permissions
About this article
Cite this article
Li, C., Hao, H. & Bi, K. Seismic performance of precast concrete-filled circular tube segmental column under biaxial lateral cyclic loadings. Bull Earthquake Eng 17, 271–296 (2019). https://doi.org/10.1007/s10518-018-0443-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10518-018-0443-4