Skip to main content
Log in

Out-of-plane behaviour of existing stone masonry buildings: experimental evaluation

  • Original Research Paper
  • Published:
Bulletin of Earthquake Engineering Aims and scope Submit manuscript

Abstract

Masonry structures can be considered as the simplest type of structures concerning its assemblage but, at the same time, it is one of the most complex construction materials in terms of mechanical properties and correct behaviour assessment. In this context, the work herein presented aims at describing an experimental testing campaign recently carried out in order to characterize the out-of-plane behaviour of traditional masonry constructions. Taking advantage of the existence of a traditional two-storey masonry building abandoned after the 1998 Azores earthquake, several in-situ tests were defined and performed with the application of quasi-static cyclic loads at the building top level in the out-of-plane direction. In addition, the efficiency of retrofitting and/or strengthening techniques applied during the 1998 Azores reconstruction process was also experimentally evaluated. Finally, an overall discussion of these techniques is presented, resorting also to previous tests’ results carried out by the same authors, aiming at inferring and suggesting quantifications of strengthening techniques’ contributions for future interventions on existing buildings. For this purpose, simple analytical mechanical approaches were adopted in order to provide numerical estimates of strength that were found in good agreement with the experimental results.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bothara JK, Dhakal RP, Mander JB (2010) Seismic performance of an unreinforced masonry building: an experimental investigation. Earthq Eng Struct Dyn 39(1): 45–68. doi:10.1002/eqe.932

    Google Scholar 

  • Carvalho A (1996) Madeiras portuguesas—estrutura anatómica, propriedades, utilizações, vol 2. Direcção Geralde Florestas

  • Carvalho E, Oliveira CS, Fragoso M, Miranda V (1998) Regras gerais de reabilitação e reconstrução de edifícios correntes afectados pela crise sísmica do faial, pico e s. Jorge iniciada pelo sismo de 9 de julho de 1998. Laboratório Nacional de Engenharia Civil (LNEC), Lisbon

  • CEN (2004) Eurocode 5: design of timber structures—part 1-1: general—common rules and rules for buildings. EN 1995-1. CEN, Brussels

  • Costa A (2002) Determination of mechanical properties of traditional masonry walls in dwellings of faial island, azores. Earthq Eng Struct Dyn 37: 1361–1382. doi:10.1002/eqe.167

    Article  Google Scholar 

  • Costa A, Arêde A (2006) Strengthening of structures damaged by the azores earthquake of 1998. Constr Build Mater 20: 252–268. doi:10.1016/j.conbuildmat.2005.08.029

    Article  Google Scholar 

  • Costa AA, Arêde A, Costa A, Oliveira CS (2011) In-situ cyclic tests on existing stone masonry walls and strengthening solutions. Earthq Eng Struct Dyn 40(4): 449–471. doi:10.1002/eqe.1046

    Article  Google Scholar 

  • D’Ayala D, Speranza E (2000) An integrated procedure for the assessment of seismic vulnerability of historic buildings. In: 12th world conference on earthquake engineering, Auckland

  • Derakhshan H (2011) Seismic assessment of out-of-plane loaded unreinforced masonry walls. PhD dissertation. University of Auckland, Auckland

  • Dusi A, Mezzi M, Manzoni E, Dusi C (2007) The use of polymeric grids for the seismic enhancement of brick masonry buildings. In: Delgado R, Costa A, Romão X (eds) \({{7^{\rm{\underline{o}}}}}\) congresso de Sismologia e Engenharia Sísmica. FEUP, SPES, Porto

  • Griffith MC, Vaculik J, Lam NTK, Wilson J, Lumantarna E (2007) Cyclic testing of unreinforced masonry walls in two-way bending. Earthq Eng Struct Dyn 36: 801–822. doi:10.1002/eqe.654

    Article  Google Scholar 

  • Magenes G, Penna A, Galasco A (2010) A full-scale shaking table test on a two-storey stone masonry building. In: Paper presented at the 14th European conference on earthquake engineering, Ohrid

  • Mosallam AS (2007) Out-of-plane flexural behavior of unreinforced red brick walls strengthened with frp composites. Compos Part B 38: 559–574. doi:10.1016/j.compositesb.2006.07.019

    Article  Google Scholar 

  • Neves F, Costa A, Oliveira CS. Vulnerabilidade sísmica do parque habitacional das ilhas do faial e pico (parte 1—danos exteriores). In: Delgado R, Costa A, Romão X (eds) \({{7^{\rm{\underline{o}}}}}\) congresso de Sismologia e Engenharia Sísmica. FEUP, SPES, Porto

  • Neves F, Costa A, Vicente R, Oliveira C, Varum H (2011) Seismic vulnerability assessment and characterisation of the buildings on faial island, azores. Bul Earthq Eng:1–18. doi:10.1007/s10518-011-9276-0

  • Penna A, Calvi GM, Costa AA. Prestazioni sismiche del calcestruzzo cellulare. In: ANIDIS 2007—XII convengo Nazionale L’Ingegneria Sismica in Italia, Pisa

  • Willis CR, Griffith MC, Lawrence SJ (2004) Horizontal bending of unreinforced clay brick masonry. Mason Int 17(3): 109–122

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alexandre A. Costa.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Costa, A.A., Arêde, A., Costa, A. et al. Out-of-plane behaviour of existing stone masonry buildings: experimental evaluation. Bull Earthquake Eng 10, 93–111 (2012). https://doi.org/10.1007/s10518-011-9332-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10518-011-9332-9

Keywords

Navigation