The effectiveness of a setup for removing stresses in the steam header of a PGV-1000 steam generator is evaluated. The evaluation is based on an investigation of the stress state by means of magnetic anisotropy measurements performed in the zone of the No. 111 weld seam of the hot header of steam generators operating in one of the power-generating units with a V-320 series reactor arrangement. Inspections made it possible to obtain cartograms of the distribution of the difference of the principal mechanical stresses along the perimeter of the weld connection of a PGV-1000 header equipped with a cooling mantle and headers without such a mantle. By means of statistical analysis of the data, a diagram of the distribution of the principal mechanical stresses was obtained. In addition, the distribution of the standard deviation of the principal mechanical stresses as a measure of the dispersion of a random quantity relative to its mathematical expectation was determined.
Similar content being viewed by others
References
S. L. Lyakishev, V. V. Denisov, S. A. Kharchenko, and O. Yu. Petrova, “Analysis of the factors damaging to the headers of the steam generator PGV-1000M,” Vopr. At. Nauki Tekhn. Ser. Obesp. Bezopasn. AES, 19, 55–68 (2007).
A. P. Letunovskii, A. A. Antonov, and O. I. Steklov, “Removal of residual stresses by low-frequency vibratory treatment,” Zagotov. Proizv. Mashinostr., No. 8, 12–16 (2012).
S. L. Lyakishev, Investigation of the Stress-Strain State and Modernization of the Design of the Coolant Header of a Steam Generator in NPP with VVER: Auth. Abstr. Dissert. Cand. Techn. Sci., Gidropress OKB, Podolsk (2011).
A. K. Adamenkov, I. N. Veselova, and I. V. Malakhov, “Provision for monitoring thermomechanical stress load on the assembly for welding coolant header to a Dc 1200 pipe connection of PGV-1000 steam generators,” Global. Yad. Bezopasn., No. 4(17), 84–89 (2015).
Author information
Authors and Affiliations
Additional information
Translated from Atomnaya Énergiya, Vol. 123, No. 2, pp. 79–81, August, 2017.
Rights and permissions
About this article
Cite this article
Adamenkov, A.K., Malakhov, I.V. & Veselova, I.N. Operational Efficiency Evaluation of a Setup for Removing Stresses in the Steam Header of PGV-1000 Steam Generator. At Energy 123, 93–95 (2017). https://doi.org/10.1007/s10512-017-0307-z
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10512-017-0307-z