Skip to main content
Log in

Monitoring Fissile and Matrix Materials in Closed Containers by Means of Pulsed Neutron Sources

  • Published:
Atomic Energy Aims and scope

Computational and experimental studies of the possibility of determining the fissile and matrix materials by means of differential neutron attenuation are presented. The time response of 235U fission under the action of 14 MeV neutrons from an ING-07T pulsed neutron generator, fabricated by VNIIA, on a 70-liter steel container holding uranium in graphite, iron and polyethylene matrices is analyzed. It is shown that milligram quantities of 235U can be detected and the matrix type and density as well as the location of fissile material inside a container can be determined.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. H. Menlove, L. Foster, and J. Baca, NBC Operational Manual Including the Multiposition Add-a-Source Function, LA 12737-M (1994).

  2. F. Jallu and F. Loche, “Improvement of non-destructive fissile mass assays in a low-level waste drums: a matrix correction method based on neutron capture gamma-rays and a neutron generator,” Nucl. Instrum. Meth. in Phys. Res. B, 266, 3674–3690 (2008).

    Article  ADS  Google Scholar 

  3. S. Melton, R. Estep, and C. Hollas, Development of Advanced Matrix Correction Techniques for Active Interrogation of Waste Drums Using of the CTEN Instrument, Preprint LA-UR-97-399 (1997).

  4. Yu. N. Barmakov, E. P. Bogolyubov, O. V. Bochkarev, et al., “System of combined active and passive control of fissile materials and their nuclide composition in nuclear wastes,” Int. J. Nucl. Energy Sci. Technol., 6, No. 2, 127–135 (2011).

    Article  Google Scholar 

  5. G. M. Bezhunov, I. P. Matveenko, and G. M. Mikhailov, “Active system with a pulsed neutron generator for measuring the amount of fissile materials in containers with wastes,” in: Portable Neutron Generators and Technologies Based on Them: Inter-Industry Sci. Techn. Conf., VNIIA, Moscow, May 26–30, 2003, p. 177.

  6. E. P. Bogolyubov, N. V. Isaev, L. A. Korytko, et al., “Use of portable neutron generators for monitoring fissile materials in wastes and process solutions,” Vopr. At. Nauki Tekhn. Ser. Yad. Priborostr., Prib. Oborud. Ucheta Kontr. Yad. Mater., No. 1(18), 37 (2000).

  7. V. A. Lippov, V. G. Nikolaev, D. F. Rau, and V. L. Romodanov, “Method of determining fissile substances in unirradiated fuel assemblies,” Vopr. At. Nauki Tekhn. Ser. Rad. Tekhn., No. 1(27), 78 (1984).

  8. MCNP – General Monte Carlo N-Particle Transport Code, Vers. 4C, LA-13709-M (2000).

Download references

Author information

Authors and Affiliations

Authors

Additional information

Translated from Atomnaya Énergiya, Vol. 115, No. 2, pp. 99–104, August, 2013.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Batyaev, V.F., Bochkarev, O.V., Sklyarov, S.V. et al. Monitoring Fissile and Matrix Materials in Closed Containers by Means of Pulsed Neutron Sources. At Energy 115, 116–122 (2013). https://doi.org/10.1007/s10512-013-9758-z

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10512-013-9758-z

Keywords

Navigation