Computational and experimental studies of the possibility of determining the fissile and matrix materials by means of differential neutron attenuation are presented. The time response of 235U fission under the action of 14 MeV neutrons from an ING-07T pulsed neutron generator, fabricated by VNIIA, on a 70-liter steel container holding uranium in graphite, iron and polyethylene matrices is analyzed. It is shown that milligram quantities of 235U can be detected and the matrix type and density as well as the location of fissile material inside a container can be determined.
Similar content being viewed by others
References
H. Menlove, L. Foster, and J. Baca, NBC Operational Manual Including the Multiposition Add-a-Source Function, LA 12737-M (1994).
F. Jallu and F. Loche, “Improvement of non-destructive fissile mass assays in a low-level waste drums: a matrix correction method based on neutron capture gamma-rays and a neutron generator,” Nucl. Instrum. Meth. in Phys. Res. B, 266, 3674–3690 (2008).
S. Melton, R. Estep, and C. Hollas, Development of Advanced Matrix Correction Techniques for Active Interrogation of Waste Drums Using of the CTEN Instrument, Preprint LA-UR-97-399 (1997).
Yu. N. Barmakov, E. P. Bogolyubov, O. V. Bochkarev, et al., “System of combined active and passive control of fissile materials and their nuclide composition in nuclear wastes,” Int. J. Nucl. Energy Sci. Technol., 6, No. 2, 127–135 (2011).
G. M. Bezhunov, I. P. Matveenko, and G. M. Mikhailov, “Active system with a pulsed neutron generator for measuring the amount of fissile materials in containers with wastes,” in: Portable Neutron Generators and Technologies Based on Them: Inter-Industry Sci. Techn. Conf., VNIIA, Moscow, May 26–30, 2003, p. 177.
E. P. Bogolyubov, N. V. Isaev, L. A. Korytko, et al., “Use of portable neutron generators for monitoring fissile materials in wastes and process solutions,” Vopr. At. Nauki Tekhn. Ser. Yad. Priborostr., Prib. Oborud. Ucheta Kontr. Yad. Mater., No. 1(18), 37 (2000).
V. A. Lippov, V. G. Nikolaev, D. F. Rau, and V. L. Romodanov, “Method of determining fissile substances in unirradiated fuel assemblies,” Vopr. At. Nauki Tekhn. Ser. Rad. Tekhn., No. 1(27), 78 (1984).
MCNP – General Monte Carlo N-Particle Transport Code, Vers. 4C, LA-13709-M (2000).
Author information
Authors and Affiliations
Additional information
Translated from Atomnaya Énergiya, Vol. 115, No. 2, pp. 99–104, August, 2013.
Rights and permissions
About this article
Cite this article
Batyaev, V.F., Bochkarev, O.V., Sklyarov, S.V. et al. Monitoring Fissile and Matrix Materials in Closed Containers by Means of Pulsed Neutron Sources. At Energy 115, 116–122 (2013). https://doi.org/10.1007/s10512-013-9758-z
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10512-013-9758-z