Abstract
The purpose, structure, and basic characteristics of an acoustic system for monitoring coolant leaks in the first loop of a VVER reactor are presented. The principle of operation of the diagnostics algorithm is described. The system has been checked on a special stand. The system satisfies all sensitivity and temporal requirements. In 2005, SAKT was put into experimental operation in the No. 3 unit of the Kalinin nuclear power plant.
Similar content being viewed by others
References
V. A. Kiselev and E. Yu. Rivkin, “Application of the leak before rupture concept in the analysis of nuclear power plant safety,” At. Énerg., 25, No. 6, 426–430 (1993).
S. A. Morozov, S. N. Kovtun, A. Yu. Uralets, et al., “Piezoelectric transducer of acoustic emission,” Russian Federation patent No. 2089897, Byull. Izobret., No. 25, 334 (1997).
S. A. Morozov, A. A. Budarin, S. N. Kovtun, et al., “Main sources of background acoustic noise of the main circulation loop of a VVER-1000 nuclear facility,” At. Énerg., 103, No. 3, 161–166 (2007).
S. A. Morozov, S. N. Kovtun, A. A. Budarin, et al., “Acoustic leak monitoring system (SAKT),” Preprint FÉI-3082 (2006).
Author information
Authors and Affiliations
Additional information
__________
Translated from Atomnaya Énergiya, Vol. 103, No. 6, pp. 342–347, December, 2007.
Rights and permissions
About this article
Cite this article
Morozov, S.A., Kovtun, S.N., Budarin, A.A. et al. Development of an acoustic leak monitoring system. At Energy 103, 925–931 (2007). https://doi.org/10.1007/s10512-007-0149-1