Abstract
Computational fluid dynamics (CFD) has been used for several years to identify mechanical risk factors associated with aneurysmal evolution and rupture as well as to understand flow characteristics before and after surgical treatments in order to help the clinical decision making process. We used the keywords, “CFD” and “aneurysms” to search recent publications since about 2000, and categorized them into (i) studies of rupture risk factors and (ii) investigations of pre- and post-evaluations of surgical treatment with devices like coils and flow diverters (FD). This search enables us to examine the current status of CFD as a clinical tool and to determine if CFD can potentially become an important part of the routine clinical practice for the evaluation and treatment of aneurysms in near future. According to previous reports, it has been argued that CFD has become a quite robust non-invasive tool for the evaluation of surgical devices, especially in the early stages of device design and it has also been applied successfully to the study of rupture risk assessment. However, we find that due to the large number of pre-processing inputs further efforts of validation and reproducibility of CFD with larger clinical datasets are still essential to identify standardized mechanical risk factors. As a result, we identify the following needs to have a robust CFD tool for clinical use: (i) more reliability tests through validation studies, (ii) analyses of larger generalized clinical datasets to find converging universal risk parameters, (iii) fluid structure interaction (FSI) analyses to better understand the detailed vascular remodeling processes associated with aneurysm growth, evolution and rupture, and (iv) better coordinated and organized communications and collaborations between engineers and clinicians.
Similar content being viewed by others
References
AneuriskWeb project website, http://ecm2.mathcs.emory.edu/aneuriskweb. Emory University, Department of Math&CS, 2012.
Antiga, L., M. Piccinelli, L. Botti, B. Ene-Iordache, A. Remuzzi, and D. A. Steinman. An image-based modeling framework for patient-specific computational hemodynamics. Med. Biol. Eng. Comput. 46(11):1097–1112, 2008.
Antiga, L., and D. A. Steinman. Rethinking turbulence in blood. Biorheology 46:77–81, 2009.
Babiker, M. H., B. Chong, L. F. Gonzalez, S. Cheema, and D. H. Frakes. Finite element modeling of embolic coil deployment: multifactor characterization of treatment effects on cerebral aneurysm hemodynamics. J. Biomech. 46(16):2809–2816, 2013.
Babiker, M. H., L. F. Gonzalez, J. Ryan, F. Albuquerque, D. Collins, A. Elvikis, and D. H. Frakes. Influence of stent configuration on cerebral aneurysm fluid dynamics. J. Biomech. 45(3):440–447, 2012.
Bacigaluppi, S., M. Piccinelli, L. Antiga, A. Veneziani, T. Passerini, P. Rampini, M. Zavanone, P. Severi, G. Tredici, G. Zona, T. Krings, E. Boccardi, S. Penco, and M. Fontanella. Factors affecting formation and rupture of intracranial saccular aneurysms. Neurosurg. Rev. 37:1–14, 2014.
Baek, H., M. V. Jayaraman, and G. E. Karniadakis. Wall shear stress and pressure distribution on aneurysms and infundibulae in the posterior communicating artery bifurcation. Ann. Biomed. Eng. 37(12):2469–2487, 2009.
Baek, H., M. V. Jayaraman, P. D. Richardson, and G. E. Karniadakis. Flow instability and wall shear stress variation in intracranial aneurysms. J. R. Soc. Interface 7(47):967–988, 2010.
Berg, P., D. Stucht, G. Janiga, O. Beuing, O. Speck, and D. Thévenin. Cerebral blood flow in a healthy Circle of Willis and two intracranial aneurysms: computational fluid dynamics versus four-dimensional phase-contrast magnetic resonance imaging. J. Biomech. Eng. 136(4):041003, 2014.
Bordás, R., S. Seshadhri, G. Janiga, M. Skalej, and D. Thévenin. Experimental validation of numerical simulations on a cerebral aneurysm phantom model. Interv. Med. Appl. Sci. 4(4):193–205, 2012.
Byun, H. S., and K. Rhee. CFD modeling of blood flow following coil embolization of aneurysms. Med. Eng. Phys. 26(9):755–761, 2004.
Castro, M. A., C. M. Putman, and J. R. Cebral. Computational fluid dynamics modeling of intracranial aneurysms: effects of parent artery segmentation on intra-aneurysmal hemodynamcis. AJNR 27:1703–1709, 2006.
Castro, M. A., C. M. Putman, and J. R. Cebral. Patient-specific computational modeling of cerebral aneurysms with multiple avenues of flow from 3D rotational angiography images. Acad. Radiol. 13(7):811–821, 2006.
Castro, M. A., C. M. Putman, M. J. Sheridan, and J. R. Cebral. Hemodynamic patterns of anterior communicating artery aneurysms: a possible association with rupture. AJNR Am. J. Neuroradiol. 30:297–302, 2009.
Cavazzuti, M., M. Atherton, M. Collins, and G. Barozzi. Beyond the virtual intracranial stenting challenge 2007: non-Newtonian and flow pulsatility effects. J. Biomech. 43(13):2645–2647, 2010.
Cavazzuti, M., M. A. Atherton, M. W. Collins, and G. S. Barozzi. Non-newtonian and flow pulsatility effects in simulation models of a stented intracranial aneurysm. Proc. Inst. Mech. Eng. H 225(6):597–609, 2011.
Cebral, J. R., M. A. Castro, J. E. Burgess, R. Pergolizzi, and C. M. Putman. Characterization of cerebral aneurysm for assessing risk of rupture using patient-specific computational hemodynamics models. AJNR Am. J. Neuroradiol. 26:2550–2559, 2005.
Cebral, J. R., and M. Raschi. Suggested connections between risk factors of intracranial aneurysms: a review. Ann. Biomed. Eng. 41(7):1366–1383, 2013.
Cebral, J. R., and H. Meng. Counterpoint: realizing the clinical utility of computational fluid dynamics-closing the gap. AJNR Am. J. Neuroradiol. 33:396–398, 2012.
Cebral, J. R., F. Mut, M. Raschi, E. Scrivano, R. Ceratto, P. Lylyk, and C. M. Putman. Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment. AJNR Am. J. Neuroradiol. 32(1):27–33, 2011.
Cebral, J. R., F. Mut, D. Sforza, R. Löhner, E. Scrivano, P. Lylyk, and C. M. Putman. Clinical application of image-based CFD for cerebral aneurysms. Int. J. Numer. Methods Biomed. Eng. 27(7):977–992, 2011.
Cebral, J. R., F. Mut, J. Weir, and C. M. Putman. Association of hemodynamic characteristics and cerebral aneurysm rupture. Am. J. Neuroradiol. 32(2):264–270, 2011.
Cebral, J. R., F. Mut, J. Weir, and C. Putman. Quantitative characterization of the hemodynamic environment in ruptured and unruptured brain aneurysms. Am. J. Neuroradiol. 32(1):145–151, 2011.
Cebral, J. R., R. S. Pergolizzi, Jr., and C. M. Putman. Computational fluid dynamics modeling of intracranial aneurysms: qualitative comparison with cerebral angiography. Acad. Radiol. 14(7):804–813, 2007.
Chien, A., S. Tateshima, M. Castro, J. Sayre, J. Cebral, and F. Viñuela. Patient-specific flow analysis of brain aneurysms at a single location: comparison of hemodynamic characteristics in small aneurysms. Med. Biol. Eng. Comput. 46(11):1113–1120, 2008.
Dhar, S., M. Tremmel, J. Mocco, M. Kim, J. Yamamoto, A. H. Siddiqui, L. N. Hopkins, and H. Meng. Morphology parameters for intracranial aneurysm rupture risk assessment. Neurosurgery 63:185–197, 2008.
Dempere-Marco, L., E. Oubel, M. Castro, C. Putman, A. Frangi, and J. Cebral. CFD analysis incorporating the influence of wall motion: application to intracranial aneurysms. Med. Image Comput. Comput. Assist. Interv. 9(2):438–445, 2006.
Evju, Ø., K. Valen-Sendstad, and K. A. Mardal. A study of wall shear stress in 12 aneurysms with respect to different viscosity models and flow conditions. J. Biomech. 46(16):2802–2808, 2013.
Ford, M. D., N. Alperin, S. H. Lee, D. W. Holdsworth, and D. A. Steinman. Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries. Physiol. Meas. 26:477–488, 2005.
Ford, M. D., Y. Hoi, M. Piccinelli, L. Antiga, and D. A. Steinman. An objective approach to digital removal of saccular aneurysms: technique and applications. Br. J. Radiol. 82:S55–S61, 2009.
Ford, M. D., H. N. Nikolov, J. S. Milner, S. P. Lownie, E. M. Demont, W. Kalata, F. Loth, D. W. Holdsworth, and D. A. Steinman. PIV-measured versus CFD-predicted flow dynamics in anatomically realistic cerebral aneurysm models. J. Biomech. Eng. 130(2):021015, 2008.
Ford, M. D., G. R. Stuhne, H. N. Nikolov, D. F. Habets, S. P. Lownie, D. W. Holdsworth, and D. A. Steinman. Virtual angiography for visualization and validation of computational models of aneurysm hemodynamics. IEEE Trans. Med. Imaging 24(12):1586–1592, 2005.
Fukasaku, K., M. Negoro, H. Iwase, K. Yokoi, and R. Himeno. Computational fluid dynamics for brain circulation and aneurysm with therapeutic devices. Interv. Neuroradiol. 10(Suppl 2):108–112, 2004.
Fukazawa, K., F. Ishida, Y. Umeda, Y. Miura, S. Shimosaka, S. Matsushima, W. Taki, and H. Suzuki. Using computational fluid dynamics analysis to characterize local hemodynamic features of middle cerebral artery aneurysm rupture points. World Neurosurg. pii:S1878-8750(13)00277-5, 2013.
Gonzalez, C. F., Y. I. Choi, H. V. Ortega, and J. Moret. Intracranial aneurysms: flow analysis of their origin and progression. AJNR Am. J. Neuroradiol. 13:181–188, 1992.
Goubergrits, L., J. Schaller, U. Kertzscher, N. van den Bruck, K. Poethkow, Ch Petz, H. C. Hege, and A. Spuler. Statistical wall shear stress maps of ruptured and unruptured middle cerebral artery aneurysms. J. R. Soc. Interface 9:677–688, 2012.
Graziano, F., V. M. Russo, W. Wang, D. Khismatullin, and A. J. Ulm. 3D computational fluid dynamics of a treated vertebrobasilar giant aneurysm: a multistage analysis. Am. J. Neuroradiol. 34(7):1387–1394, 2013.
Grinberg, L., D. A. Fedosov, and G. E. Karniadakis. Parallel multiscale simulations of a brain aneurysm. J. Comput. Phys. 244:131–147, 2013.
Hassan, T., M. Ezura, E. V. Timofeev, T. Tominaga, T. Saito, A. Takahashi, K. Takayama, and T. Yoshimoto. Computational simulation of therapeutic parent artery occlusion to treat giant vertebrobasilar aneurysm. AJNR Am. J. Neuroradiol. 25(1):63–68, 2004.
Hademenos, G. J., and T. F. Massoud. Biophysical mechanisms of stroke. Stroke 28(10):2067–2077, 1997.
Hodis, S., S. Uthamaraj, G. Lanzino, D. F. Kallmes, and D. Dragomir-Daescu. Computational fluid dynamics simulation of an anterior communicating artery ruptured during angiography. J. Neurointerv. Surg. 6(2):e14, 2014.
Hodis, S., S. Uthamaraj, A. L. Smith, K. D. Dennis, D. F. Kallmes, and D. Dragomir-Daescu. Grid convergence errors in hemodynamic solution of patient-specific cerebral aneurysms. J. Biomech. 45:2907–2913, 2012.
Hoi, Y., S. H. Woodward, M. Kim, D. B. Taulbee, and H. Meng. Validation of CFD simulations of cerebral aneurysms with implication of geometric variations. J. Biomech. Eng. 128(6):844–851, 2006.
Isaksen, J. G., Y. Bazilevs, T. Kvamsdal, Y. Zhang, J. H. Kaspersen, K. Waterloo, B. Romner, and T. Ingebrigtsen. Determination of wall tension in cerebral artery aneurysms by numerical simulation. Stroke 39:3172–3178, 2008.
Isoda, H., Y. Ohkura, T. Kosugi, M. Hirano, M. T. Alley, R. Bammer, N. J. Pelc, H. Namba, and H. Sakahara. Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamics. Neuroradiology 52(10):913–920, 2010.
Kallmes, D. F. Point: CFD-computational fluid dynamics or confounding factor dissemination. AJNR Am. J. Neuroradiol. 33:395–396, 2012.
Karmonik, C., G. Chintalapani, T. Redel, Y. J. Zhang, O. Diaz, R. Klucznik, and R. G. Grossman. Hemodynamics at the ostium of cerebral aneurysms with relation to post-treatment changes by a virtual flow diverter: a computational fluid dynamics study. Conf. Proc. IEEE Eng. Med. Biol. Soc. 2013:1895–1898, 2013.
Karmonik, C., R. Klucznik, and G. Benndorf. Comparison of velocity patterns in an AComA aneurysm measured with 2D phase contrast MRI and simulated with CFD. Technol. Health Care 16:119–128, 2008.
Karmonik, C., C. Yen, O. Diaz, R. Klucznik, R. G. Grossman, and G. Benndorf. Temporal variations of wall shear stress parameters in intracranial aneurysms-importance of patient-specific inflow waveforms for CFD calculations. Acta Neurochir. 152:1391–1398, 2010.
Karmonik, C., C. Yen, E. Gabriel, S. Partovi, M. Horner, Y. J. Zhang, R. P. Klucznik, O. Diaz, and R. G. Grossman. Quantification of speed-up and accuracy of multi-CPU computational flow dynamics simulations of hemodynamics in a posterior communicating artery aneurysm of complex geometry. J. Neurointerv. Surg. 5(Suppl 3):iii48–55, 2013.
Kim, M., C. Ionita, R. Tranquebar, K. R. Hoffmann, D. B. Taulbee, H. Meng, and S. Rudin. Evaluation of an asymmetric stent patch design for a patient specific intracranial aneurysm using Computational Fluid Dynamic (CFD) calculations in the Computed Tomography (CT) derived lumen. Proc. Soc. Photo Opt. Instrum. Eng. 6143. pii:61432G, 2006.
Koebbe, C. J., E. Veznedaroglu, P. Jabbour, and R. H. Rosenwasser. Endovascular management of intracranial aneurysms: current experience and future advances. Neurosurgery 59(5 Suppl 3):S93–S102; discussion S3–13. Review, 2006.
Kono, K., and T. Terada. Hemodynamics of 8 different configurations of stenting for bifurcation aneurysms. AJNR Am. J. Neuroradiol. 34(10):1980–1986, 2013.
Kono, K., and T. Terada. Treatment strategy and follow-up evaluation for an unruptured anterior communicating artery aneurysm associated with pseudo-occlusion of the internal carotid artery using computational fluid dynamics simulations. Turk. Neurosurg. 24(1):111–116, 2014.
Kono, K., N. Tomura, R. Yoshimura, and T. Terada. Changes in wall shear stress magnitude after aneurysm rupture. Acta Neurochir. Wien 155(8):1559–1563, 2013.
Kulcsár, Z., L. Augsburger, P. Reymond, V. M. Pereira, S. Hirsch, A. S. Mallik, J. Millar, S. G. Wetzel, I. Wanke, and D. A. Rüfenacht. Flow diversion treatment: intra-aneurismal blood flow velocity and WSS reduction are parameters to predict aneurysm thrombosis. Acta Neurochir. Wien 154(10):1827–1834, 2012.
Kurokawa, Y., S. Abiko, and K. Watanabe. Noninvasive detection of intracranial vascular lesions by recording blood flow sounds. Stroke 25:397–402, 1994.
Larrabide, I., M. L. Aguilar, H. G. Morales, A. J. Geers, Z. Kulcsár, D. A. Rüfenacht, and A. F. Frangi. Intra-aneurysmal pressure and flow changes induced by flow diverters: relation to aneurysm size and shape. AJNR Am. J. Neuroradiol. 34(4):816–822, 2013.
Larrabide, I., M. Kim, L. Augsburger, M. C. Villa-Uriol, D. Rüfenacht, and A. F. Frangi. Fast virtual deployment of self-expandable stents: method and in vitro evaluation for intracranial aneurysmal stenting. Med. Image Anal. 16(3):721–730, 2012.
Lauric, A., J. Hippelheuser, A. D. Cohen, L. M. Kadasi, and A. M. Malek. Wall shear stress association with rupture status in volume matched sidewall aneurysms. J. NeuroIntervent. Surg. 0:1–8, 2013.
Lee, C. J., Y. Zhang, H. Takao, Y. Murayama, and Y. Qian. A fluid-structure interaction study using patient-specific ruptured and unruptured aneurysm: the effect of aneurysm morphology, hypertension and elasticity. J. Biomech. 46(14):2402–2410, 2013.
Lieber, B. B., and C. Sadasivan. Endoluminal scaffolds for vascular reconstruction and exclusion of aneurysms from the cerebral circulation. Stroke 41(10 Suppl.):S21–S25, 2010.
Liou, T. M., and S. N. Liou. A review on in vitro studies of hemodynamic characteristics in terminal and lateral aneurysm models. Proc. Natl. Sci. Counc. Repub. China B 23(4):133–148, 1999.
Lu, G., L. Huang, X. L. Zhang, S. Z. Wang, Y. Hong, Z. Hu, and D. Y. Geng. Influence of hemodynamic factors on rupture of intracranial aneurysms: patient-specific 3D mirror aneurysms model computational fluid dynamics simulation. AJNR Am. J. Neuroradiol. 32(7):1255–1261, 2011.
Ma, D., G. F. Dargush, S. K. Natarajan, E. I. Levy, A. H. Siddiqui, and H. Meng. Computer modeling of deployment and mechanical expansion of neurovascular flow diverter in patient-specific intracranial aneurysms. J. Biomech. 45(13):2256–2263, 2012.
Mantha, A., C. Karmonik, G. Benndorf, C. Strother, and R. Metcalfe. Hemodynamics in a cerebral artery before and after the formation of an aneurysm. AJNR Am. J. Neuroradiol. 27:1113–1118, 2006.
Marzo, A., P. Singh, I. Larrabide, A. Radaelli, S. Coley, M. Gwilliam, I. D. Wilkinson, P. Lawford, P. Reymond, U. Patel, A. Frangi, and D. R. Hose. Computational hemodynamics in cerebral aneurysms: the effects of modeled versus measured boundary conditions. Ann. Biomed. Eng. 39(2):884–896, 2011.
Mitsos, A. P., N. M. Kakalis, Y. P. Ventikos, and J. V. Byrne. Haemodynamic simulation of aneurysm coiling in an anatomically accurate computational fluid dynamics model: technical note. Neuroradiology 50(4):341–347, 2008.
Morales, H. G., I. Larrabide, A. J. Geers, L. San Román, J. Blasco, J. M. Macho, and A. F. Frangi. A virtual coiling technique for image-based aneurysm models by dynamic path planning. IEEE Trans. Med. Imaging 32(1):119–129, 2013.
Morales, H. G., I. Larrabide, A. J. Geers, M. L. Aguilar, and A. F. Frangi. Newtonian and non-Newtonian blood flow in coiled cerebral aneurysms. J. Biomech. 46(13):2158–2164, 2013.
Mut, F., R. Löhner, A. Chien, S. Tateshima, F. Viñuela, C. M. Putman, and J. R. Cebral. Computational hemodynamics framework for the analysis of cerebral aneurysms. Int. J. Numer. Methods Biomed. Eng. 27(6):822–839, 2011.
Mut, F., M. Raschi, E. Scrivano, C. Bleise, J. Chudyk, R. Ceratto, P. Lylyk, and J. R. Cebral. Association between hemodynamic conditions and occlusion times after flow diversion in cerebral aneurysms. J. NeuroIntervent. Surg. 0:1–5, 2014.
Omodaka, S., S. Sugiyama, T. Inoue, K. Funamoto, M. Fujimura, H. Shimizu, T. Hayase, A. Takahashi, and T. Tominaga. Local hemodynamics at the rupture point of cerebral aneurysms determined by computational fluid dynamics analysis. Cerebrovasc. Dis. 34(2):121–129, 2012.
Onishi, Y., K. Aoki, K. Amaya, T. Shimizu, H. Isoda, Y. Takehara, H. Sakahara, and T. Kosugi. Accurate determination of patient-specific boundary conditions in computational vascular hemodynamics using 3D cine phase-contrast MRI. Int. J Numer. Methods Biomed. Eng. 29(10):1089–1103, 2013.
Ortega, H. V. Computer simulation helps predict cerebral aneurysms. J. Med. Eng. Technol. 22(4):179–181, 1998.
Passerini, T., L. M. Sangalli, S. Vantini, M. Piccinelli, S. Bacigaluppi, L. Antiga, E. Boccardi, P. Secchi, and A. Veneziani. An integrated statistical investigation of internal carotid arteries of patients affected by cerebral aneurysms. Cardiovasc. Eng. Technol. 3(1):26–40, 2012.
Pereira, V. M., O. Brina, A. Marcos Gonzales, A. P. Narata, P. Bijlenga, K. Schaller, K. O. Lovblad, and R. Ouared. Evaluation of the influence of inlet boundary conditions on computational fluid dynamics for intracranial aneurysms: a virtual experiment. J. Biomech. 46(9):1531–1539, 2013.
Piccinelli, M., D. A. Steinman, Y. Hoi, F. Tong, A. Veneziani, and L. Antiga. Automatic neck plane detection and 3D geometric characterization of aneurysmal sacs. Ann. Biomed. Eng. 40(10):2188–2211, 2012.
Piccinelli, M., A. Veneziani, D. A. Steinman, A. Remuzzi, and L. Antiga. A framework for geometric analysis of vascular structures: application to cerebral aneurysms. IEEE Trans. Med. Imaging 28(8):1141–1155, 2009.
Polevaya, N. V., M. Y. Kalani, G. K. Steinberg, and V. C. Tse. The transition from hunterian ligation to intracranial aneurysm clips: a historical perspective. Neurosurg. Focus 20(6):E3, 2006.
Qian, Y., H. Takao, M. Umezu, and Y. Murayama. Risk analysis of unruptured aneurysms using computational fluid dynamics technology: preliminary results. Am. J. Neuroradiol. 32(10):1948–1955, 2011.
Qiu, X., Z. Fei, W. Wang, and Z. Cao. Numerical analysis on hemodynamics of cerebral aneurysm clip. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 29(1):102–106, 111, 2012.
Radae, A. G., lli, L. Augsburger, J. R. Cebral, M. Ohta, D. A. Rüfenacht, R. Balossino, G. Benndorf, D. R., Hose, A. Marzo, R. Metcalfe, P. Mortier, F. Mut, P. Reymond, L. Socci, B. Verhegghe, and A. F. Frangi. Reproducibility of haemodynamical simulations in a subject-specific stented aneurysm model-a report on the Virtual Intracranial Stenting Challenge 2007. J. Biomech. 41(10):2069–2081, 2008.
Raschi, M., F. Mut, G. Byrne, C. M. Putman, S. Tateshima, F. Viñuela, T. Tanoue, K. Tanishita, and J. R. Cebral. CFD and PIV analysis of hemodynamics in a growing intracranial aneurysm. Int. J. Numer. Methods Biomed. Eng. 28:214–228, 2012.
Rayz, V. L., L. Boussel, G. Acevedo-Bolton, A. J. Martin, W. L. Young, M. T. Lawton, R. Higashida, and D. Saloner. Numerical simulations of flow in cerebral aneurysms: comparison of CFD results and in vivo MRI measurements. J. Biomech. Eng. 130(5):051011, 2008.
Reymond, P., F. Merenda, F. Perren, D. Rüfenacht, and N. Stergiopulos. Validation of a one-dimensional model of the systemic arterial tree. Am. J. Physiol. Heart Circ. Physiol. 297(1):H208–H222, 2009.
Robertson, A. M., and P. N. Watton. Computational fluid dynamics in aneurysm research: critical reflections, future directions. AJNR Am. J. Neuroradiol. 33:992–995, 2012.
O’Rourke, M. J., and J. P. McCullough. A comparison of the measured and predicted flowfield in a patient-specific model of an abdominal aortic aneurysm. Proc. Inst. Mech. Eng. H 222(5):737–750, 2008.
Russell, J. H., N. Kelson, M. Barry, M. Pearcy, D. F. Fletcher, and C. D. Winter. Computational fluid dynamic analysis of intracranial aneurysmal bleb formation. Neurosurgery 73(6):1061–1068, 2013.
Sangalli, L. M., P. Secchi, S. Vantini, and A. Veneziani. A case study in exploratory functional data analysis: geometrical features of the internal carotid artery. J. Am. Stat. Assoc. 104(485):37–48, 2009.
Sangalli, L. M., P. Secchi, S. Vantini, and V. Vitelli. Functional clustering and alignment methods with applications. CAIM. 1(1):205–224, 2010.
Sangalli, L. M., P. Secchi, S. Vantini, and V. Vitelli. K-mean alignment for curve clustering. Comput. Stat. Data Anal. 54:1219–1233, 2010.
Schneiders, J. J., S. P. Ferns, P. van Ooij, M. Siebes, A. J. Nederveen, R. van den Berg, J. van Lieshout, G. Jansen, E. vanBavel, and C. B. Majoie. Comparison of phase-contrast MR imaging and endovascular sonography for intracranial blood flow velocity measurements. AJNR Am. J. Neuroradiol. 33(9):1786–1790, 2012.
Schneiders, J. J., H. A. Marquering, L. Antiga, R. van den Berg, E. VanBavel, and C. B. Majoie. Intracranial aneurysm neck size overestimation with 3D rotational angiography: the impact on intra-aneurysmal hemodynamics simulated with computational fluid dynamics. AJNR Am. J. Neuroradiol. 34(1):121–128, 2013.
Schneiders, J. J., H. A. Marquering, R. van den Berg, E. VanBavel, B. Velthuis, G. J. E. Rinkel, and C. B. Majoie. Rupture-associated changes of cerebral aneurysm geometry: high-resolution 3D imaging before and after rupture. AJNR Am. J. Neuroradiol. 2014. doi:10.3174/ajnr.A3866.
Seifert, V., H. A. Trost, and D. Stolke. Management morbidity and mortality in grade IV and V patients with aneurysmal subarachnoid haemorrhage. Acta Neurochir. Wien 103(1–2):5–10, 1990.
Sforza, D. M., R. Löhner, C. Putman, and J. Cebral. Hemodynamic analysis of intracranial aneurysms with moving parent arteries: basilar tip aneurysms. Int. J. Numer. Methods Biomed. Eng. 26(10):1219–1227, 2010.
Sforza, D. M., C. M. Putman, E. Scrivano, P. Lylyk, and J. R. Cebral. Blood-flow characteristics in a terminal basilar tip aneurysm prior to its fatal rupture. AJNR Am. J. Neuroradiol. 31(6):1127–1131, 2010.
Shi, C., M. Kojima, H. Anzai, C. Tercero, S. Ikeda, M. Ohta, T. Fukuda, F. Arai, Z. Najdovski, M. Negoro, and K. Irie. In vitro strain measurements in cerebral aneurysm models for cyber-physical diagnosis. Int. J. Med. Robot. 9(2):213–222, 2013.
Shimogonya, Y., T. Ishikawa, Y. Imai, N. Matsuki, and T. Yamaguchi. Can temporal fluctuation in spatial wall shear stress gradient initiate a cerebral aneurysm? A proposed novel hemodynamic index, the gradient oscillatory number (GON). J. Biomech. 42:550–554, 2009.
Shojima, M., M. Oshima, K. Takagi, R. Torii, M. Hayakawa, K. Katada, A. Morita, and T. Kirino. Magnitude and role of wall shear stress on cerebral aneurysm: computational fluid dynamic study of 20 middle cerebral artery aneurysms. Stroke 35(11):2500–2505, 2004.
Shojima, M., A. Morita, T. Kimura, M. Oshima, T. Kin, and N. Saito, Computational fluid dynamic simulation of a giant basilar tip aneurysm with eventual rupture following Hunterian ligation. World Neurosurg. pii: S1878-8750(13)01218-7, 2013.
Singh, P. K., A. Marzo, S. C. Coley, G. Berti, P. Bijlenga, P. V. Lawford, M. Villa-Uriol, D. A. Rufenacht, K. M. McCormack, A. Frangi, U. J. Patel, and D. R. Hose. The role of computational fluid dynamics in the management of unruptured intracranial aneurysms: a clinicians’ view. Comput. Intell. Neurosci. 2009, Article ID 760364, 2009.
Spiegel, M., T. Redel, Y. Zhang, T. Struffert, J. Hornegger, R. G. Grossman, A. Doerfler, and C. Karmonik. Tetrahedral and polyhedral mesh evaluation for cerebral hemodynamic simulation—a comparison. Conf. Proc. IEEE Eng. Med. Biol. Soc. 2009:2787–2790, 2009.
Spiegel, M., T. Redel, Y. J. Zhang, T. Struffert, J. Hornegger, R. G. Grossman, A. Doerfler, and C. Karmonik. Tetrahedral vs. polyhedral mesh size evaluation on flow velocity and wall shear stress for cerebral hemodynamic simulation. Comput. Methods Biomech. Biomed. Eng. 14(1):9–22, 2011.
Stehbens, W. E. Etiology of intracranial berry aneurysms. J. Neurosurg. 70:823–831, 1989.
Steiger, H. J and H. J. Reulen. Low frequency flow fluctuations in saccular aneurysms. Acta Neurochir. Wien 83:131–137, 1986.
Steinberg, G. K., C. G. Drake, and S. J. Peerless. Deliberate basilar or vertebral artery occlusion in the treatment of intracranial aneurysms. Immediate results and long-term outcome in 201 patients. J. Neurosurg. 79:161–173, 1993.
Steinman, D. A., Y. Hoi, P. Fahy, L. Morris, M. T. Walsh, N. Aristokleous, A. S. Anayiotos, Y. Papaharilaou, A. Arzani, S. C. Shadden, P. Berg, G. Janiga, J. Bols, P. Segers, N. W. Bressloff, M. Cibis, F. H. Gijsen, S. Cito, J. Pallarés, L. D. Browne, J. A. Costelloe, A. G. Lynch, J. Degroote, J. Vierendeels, W. Fu, A. Qiao, S. Hodis, D. F. Kallmes, H. Kalsi, Q. Long, V. O. Kheyfets, E. A. Finol, K. Kono, A. M. Malek, A. Lauric, P. G. Menon, K. Pekkan, M. Esmaily Moghadam, A. L. Marsden, M. Oshima, K. Katagiri, V. Peiffer, Y. Mohamied, S. J. Sherwin, J. Schaller, L. Goubergrits, G. Usera, M. Mendina, K. Valen-Sendstad, D. F. Habets, J. Xiang, H. Meng, Y. Yu, G. E. Karniadakis, N. Shaffer, and F. Loth. Variability of computational fluid dynamics solutions for pressure and flow in a giant aneurysm: the ASME 2012 Summer Bioengineering Conference CFD Challenge. J. Biomech. Eng. 135(2):021016, 2013.
Steinman, D. A., J. S. Milner, C. J. Norley, S. P. Lownie, and D. W. Holdsworth. Image-based computational simulation of flow dynamics in a giant intracranial aneurysm. AJNR Am. J. Neuroradiol. 24:559–566, 2003.
Strother, C. M., and J. Jiang. Intracranial aneurysms, cancer, X-rays, and computational fluid dynamics. AJNR Am. J. Neuroradiol. 33:991–992, 2012.
Sun, Q., A. Groth, M. Bertram, I. Waechter, T. Bruijns, R. Hermans, and T. Aach. Phantom-based experimental validation of computational fluid dynamics simulations on cerebral aneurysms. Med. Phys. 37(9):5054–5065, 2010.
Sun, Q., A. Groth, and T. Aach. Comprehensive validation of computational fluid dynamics simulations of in vivo blood flow in patient-specific cerebral aneurysms. Med. Phys. 39(2):742–754, 2012.
Tanemura, H., F. Ishida, Y. Miura, Y. Umeda, K. Fukazawa, H. Suzuki, H. Sakaida, S. Matsushima, S. Shimosaka, and W. Taki. Changes in hemodynamics after placing intracranial stents. Neurol. Med. Chir. (Tokyo) 53(3):171–178, 2013.
Tremmel, M., J. Xiang, S. K. Natarajan, L. N. Hopkins, A. H. Siddiqui, E. I. Levy, and H. Meng. Alteration of intra-aneurysmal hemodynamics for flow diversion using Enterprise and Vision stents. World Neurosurg. 74(2–3):306–315, 2010.
Valen-Sendstad, K., K. Mardal, M. Mortensen, B. A. P. Reif, and H. P. Langtangen. Direct numerical simulation of transitional flow in a patient-specific intracranial aneurysm. J. Biomech. 44:2826–2832, 2011.
Valen-Sendstad, K., K. Mardal, and D. A. Steinman. High-resolution CFD detects high-frequency velocity fluctuations in bifurcation, but not sidewall, aneurysms. J. Biomech. 46:402407, 2013.
Valencia, A., P. Burdiles, M. Ignat, J. Mura, E. Bravo, R. Rivera, and J. Sordo. Fluid structural analysis of human cerebral aneurysm using their own wall mechanical properties. Comput. Math. Methods Med. 2013:293128, 2013.
Walcott, B. P., J. M. Pisapia, B. V. Nahed, K. T. Kahle, and C. S. Ogilvy. Early experience with flow diverting endoluminal stents for the treatment of intracranial aneurysms. J. Clin. Neurosci. 18(7):891–894, 2011.
Wang, W., F. Graziano, V. Russo, A. J. Ulm, D. D. Kee, and D. B. Khismatullin. Giant intracranial aneurysm embolization with a yield stress fluid material: insights from CFD analysis. Biorheology 50(3–4):99–114, 2013.
Wong, G. K., and W. S. Poon. Current status of computational fluid dynamics for cerebral aneurysms: the clinician’s perspective. J. Clin. Neurosci. 18(10):1285–1288, 2011.
Xiang, J., M. Tremmel, J. Kolega, E. I. Levy, S. K. Natarajan, and H. Meng. Newtonian viscosity model could overestimate wall shear stress in intracranial aneurysm domes and underestimate rupture risk. J. Neurointerv. Surg. 4(5):351–357, 2012.
Xiang, J., S. K. Natarajan, M. Tremmel, D. Ma, J. Mocco, L. N. Hopkins, A. H. Siddiqui, E. I. Levy, and H. Meng. Hemodynamic-morphologic discriminants for intracranial aneurysm rupture. Stroke 42(1):144–152, 2011.
Xiang, J., V. M. Tutino, K. V. Snyder, and H. Meng. CFD: computational fluid dynamics or confounding factor dissemination? The role of hemodynamics in intracranial aneurysm rupture risk assessment. AJNR Am. J. Neuroradiol. Rev. 2013. doi:10.3174/ajnr.A3710.
Zeng, Z., M. J. Durka, D. F. Kallmes, Y. Ding, and A. M. Robertson. Can aspect ratio be used to categorize intra-aneurysmal hemodynamics? A study of elastase induced aneurysms in rabbit. J. Biomech. 44(16):2809–2816, 2011.
Zeng, Z., D. F. Kallmes, M. J. Durka, Y. Ding, D. Lewis, R. Kadirvel, and A. M. Robertson. Sensitivity of CFD based hemodynamic results in rabbit aneurysm models to idealizations in surrounding vasculature. J. Biomech. Eng. 132(9):091009, 2010.
Zhang, Y. X., Q. S. Lu, and Z. P. Jing. Multilayer stents, a new progress in the endovascular treatment of aneurysms. Chin. Med. J. (Engl.) 126(3):536–541, 2013.
Zhang, Y., H. Takao, Y. Murayama, and Y. Qian. Propose a wall shear stress divergence to estimate the risks of intracranial aneurysm rupture. ScientificWorldJournal. 2013:508131, 2013.
Zhang, Y. S., X. J. Yang, S. Z. Wang, A. K. Qiao, J. L. Chen, K. Y. Zhang, Z. C. Liu, Y. J. Zhao, Y. Zhang, B. Luo, and C. H. Li. Hemodynamic effects of stenting on wide-necked intracranial aneurysms. Chin. Med. J. (Engl.) 123(15):1999–2003, 2010.
Author information
Authors and Affiliations
Corresponding author
Additional information
Associate Editor Diego Gallo oversaw the review of this article.
Rights and permissions
About this article
Cite this article
Chung, B., Cebral, J.R. CFD for Evaluation and Treatment Planning of Aneurysms: Review of Proposed Clinical Uses and Their Challenges. Ann Biomed Eng 43, 122–138 (2015). https://doi.org/10.1007/s10439-014-1093-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10439-014-1093-6