Abstract

A fiber optic plethysmograph (FOP) has been redesigned and used to monitor cardiac activity in real time during apnoea. The device was tested using four healthy subjects aged between 23 and 31, and it is concluded that the device performs reliably. Advanced algorithms have been developed and implemented to perform the cardiac signal extraction. A strong correlation is noted between the signals derived using the FOP and the respiratory inductive plethysmograph (RIP) when the latter has also been applied to monitor cardiac activity. The approach developed for interpreting thoracocardiograms (TCGs) and abdominocardiograms (ACGs) derived from the RIP is therefore directly applicable to the interpretation of the corresponding FOP signals. The prospect of using the FOP system for real-time gating in a magnetic resonance (MR) scanner environment is discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

FIGURE 1.
FIGURE 2.
FIGURE 3.
FIGURE 4.
FIGURE 5.
FIGURE 6.
FIGURE 7.

Similar content being viewed by others

REFERENCES

  1. Augousti, A. T., and A. Raza. The development of a fibre optic respiratory plethysmograph. In: Sensors VI: Technology, Systems and Applications. Bristol: Institute of Physics Publishing, 1993, 401–406.

  2. Babchenko, A., B. Khanoch, Y. Shomer, and M. Nitzan. Fibre optic sensor for the measurement of respiratory chest circumference changes. J. Biomed. Opt. 4:224–229, 1999.

    Article  Google Scholar 

  3. Babchenko, A., B. Khanoch, Y. Shomer, and M. Nitzan. A fibre optic sensor for the measurement of breathing effort. SPIE Proc. 2631:64–71, 1999.

    Article  Google Scholar 

  4. Bazett, H. C. An analysis of the time relation of electrocardiograms. Heart 7:353–370, 1920.

    Google Scholar 

  5. Bloch, K. E., S. Jugoon, and M. A. Sackner. Thoracocardiography: Non-invasive monitoring of left ventricular filling. J. Crit. Care 14:177–185, 1999.

    Article  PubMed  CAS  Google Scholar 

  6. Bloch, K. E., S. Jugoon, H. De Socarraz, K. E. Manning, and M. A. Sackner. Thoracocardiography: Non-invasive monitoring of left ventricular stroke volume. J. Crit. Care 13:146–157, 1998.

    Article  PubMed  CAS  Google Scholar 

  7. Jordan, C., K. Henke, A. Stone, L. Brandwayn, A. Belsito, and M. Sackner. Measurement of systolic time intervals during exercise using inductive plethysmography. Int. J. Clin. Monit. Comput. 1:137–146, 1984.

    Article  PubMed  CAS  Google Scholar 

  8. Raza, A., and A. T. Augousti. Further development of a fibre optic respiratory plethysmograph. In: Proceedings of Applied Optics and OptoElectronic Conference, UK pp. 271–273, 1994.

  9. Raza, A., A. T. Augousti, and M. Graves. Optical instrumentation for respiration measurement in magnetic resonance scanners. In: Proceedings of 7th IEE Progress in Fibre Optic Sensors and Their Applications. pp. 15/1–15/5, 1995.

  10. Sanchez-Ortiz, G. I., and P. Burger. A Novel Gating Technique for Cardiac NMR Imaging using Heartbeat Time Intervals Forecast. International Workshop on Nonlinear Dynamics, Fractality and Self Organization of Complex Systems, p. D7, Wuerzburg, Germany, 1994.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. T. Augousti.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Augousti, A.T., Maletras, F.X. & Mason, J. Evaluation of Cardiac Monitoring Using Fiber Optic Plethysmography. Ann Biomed Eng 34, 416–425 (2006). https://doi.org/10.1007/s10439-005-9060-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10439-005-9060-x

Keywords

Navigation