Abstract
Various microfluidic architectures designed for in vivo and point-of-care diagnostic applications require larger channels, autonomous actuation, and portability. In this paper, we present a normally closed microvalve design capable of fully autonomous actuation for wide diameter microchannels (tens to hundreds of µm). We fabricated the multilayer plunger-membrane valve architecture using the silicone elastomer, poly-dimethylsiloxane (PDMS) and optimized it to reduce the force required to open the valve. A 50-µm Nitinol (NiTi) shape memory alloy wire is incorporated into the device and can operate the valve when actuated with 100-mA current delivered from a 3-V supply. We characterized the valve for its actuation kinetics using an electrochemical assay and tested its reliability at 1.5-s cycle duration for 1 million cycles during which we observed no operational degradation.
Similar content being viewed by others
References
Amin AM, Thakur R, Madren S et al (2013) Software-programmable continuous-flow multi-purpose lab-on-a-chip. Microfluid Nanofluidics. https://doi.org/10.1007/s10404-013-1180-2
Au AK, Lai H, Utela BR, Folch A (2011) Microvalves and micropumps for BioMEMS. Micromachines 2:179–220. https://doi.org/10.3390/mi2020179
Augustine S, Gu P, Zheng X et al (2015) Low-power electrically controlled thermoelastic microvalves integrated in thermoplastic microfluidic devices. Microfluid Nanofluidics 19:1385–1394. https://doi.org/10.1007/s10404-015-1653-6
Baek JY, Park JY, Il JuJ et al (2005) A pneumatically controllable flexible and polymeric microfluidic valve fabricated via in situ development. J. Micromechanics Microengineering 15:1015–1020. https://doi.org/10.1088/0960-1317/15/5/017
Chen H, Gu W, Cellar N et al (2008) Electromechanical properties of pressure-actuated poly (dimethylsiloxane) microfluidic push-down valves. Anal. Chem. 80:6110–6113
Chen S, Lu S, Liu Y et al (2016) A normally-closed piezoelectric micro-valve with flexible stopper. AIP Adv. https://doi.org/10.1063/1.4947301
Chuang H-S, Thakur R, Wereley ST (2012) Characterizations of gas purge valves for liquid alignment and gas removal in a microfluidic chip. J Micromechanics Microengineering. https://doi.org/10.1088/0960-1317/22/8/085023
Desai AV, Tice JD, Apblett CA, Kenis PJA (2012) Design considerations for electrostatic microvalves with applications in poly(dimethylsiloxane)-based microfluidics. Lab Chip 12:1078. https://doi.org/10.1039/c2lc21133e
Díaz-González M, Fernández-Sánchez C, Baldi A (2016) Multiple actuation microvalves in wax microfluidics. Lab Chip. https://doi.org/10.1039/C6LC00800C
Evans AT, Park JM, Chiravuri S, Gianchandani YB (2010) A low power, microvalve regulated architecture for drug delivery systems. Biomed. Microdevices 12:159–168. https://doi.org/10.1007/s10544-009-9372-y
Gui L, Ren CL (2011) Exploration and evaluation of embedded shape memory alloy (SMA) microvalves for high aspect ratio microchannels. Sensors Actuators A Phys. 168:155–161. https://doi.org/10.1016/j.sna.2011.03.038
Guler MT, Beyazkilic P, Elbuken C (2017) A versatile plug microvalve for microfluidic applications. Sensors Actuators A Phys. 265:224–230. https://doi.org/10.1016/j.sna.2017.09.001
Herr AE, Hatch AV, Throckmorton DJ et al (2007) Microfluidic immunoassays as rapid saliva-based clinical diagnostics. Proc. Natl. Acad. Sci. 104:5268–5273. https://doi.org/10.1073/pnas.0607254104
Jang L-W, Razu ME, Jensen EC et al (2016) A fully automated microfluidic micellar electrokinetic chromatography analyzer for organic compound detection. Lab Chip 16:3558–3564. https://doi.org/10.1039/C6LC00790B
Jensen EC, Stockton AM, Chiesl TN et al (2013) Digitally programmable microfluidic automaton for multiscale combinatorial mixing and sample processing. Lab Chip 13:288–296. https://doi.org/10.1039/C2LC40861A
Kim J, Kang M, Jensen EC, Mathies RA (2012) Lifting gate polydimethylsiloxane microvalves and pumps for microfluidic control. Anal. Chem. 84:2067–2071. https://doi.org/10.1021/ac202934x
Kim J, Stockton AM, Jensen EC, Mathies RA (2016) Pneumatically actuated microvalve circuits for programmable automation of chemical and biochemical analysis. Lab Chip 16:812–819. https://doi.org/10.1039/C5LC01397F
Mark D, Haeberle S, Roth G et al (2010) Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications. NATO Sci. Peace Secur. Ser. A Chem. Biol. https://doi.org/10.1007/978-90-481-9029-4-17
Mohan R, Schudel BR, Desai AV et al (2011) Design considerations for elastomeric normally closed microfluidic valves. Sensors Actuators B Chem. 160:1216–1223. https://doi.org/10.1016/j.snb.2011.09.051
Oh KW, Ahn CH (2006) A review of microvalves. J. Micromechanics Microengineering 16:R13–R39. https://doi.org/10.1088/0960-1317/16/5/R01
Rogers CI, Oxborrow JB, Anderson RR et al (2014) Microfluidic valves made from polymerized polyethylene glycol diacrylate. Sensors Actuators B Chem. 191:438–444. https://doi.org/10.1016/j.snb.2013.10.008
Vyawahare S, Sitaula S, Martin S et al (2008) Electronic control of elastomeric microfluidic circuits with shape memory actuators. Lab Chip 8:1530. https://doi.org/10.1039/b804515a
Weibel DB, Kruithof M, Potenta S et al (2005) Torque-actuated valves for microfluidics. Anal Chem 77:4726–4733. https://doi.org/10.1021/ac048303p
Acknowledgements
We thank Kevin King, Annie Mao, and Scott Sterrett for previous microfluidics work toward safe DC stimulator design. We also acknowledge the funding sources that made this work possible: MedEl Corporate Grant: FK2350 and NIH R01NS092726.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Cheng, C., Nair, A.R., Thakur, R. et al. Normally closed plunger-membrane microvalve self-actuated electrically using a shape memory alloy wire. Microfluid Nanofluid 22, 29 (2018). https://doi.org/10.1007/s10404-018-2049-1
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s10404-018-2049-1