Skip to main content
Log in

Analysis of refractive artifacts by reconstructed three-dimensional ultrasound imaging

  • ORIGINAL ARTICLE
  • Published:
Journal of Medical Ultrasonics Aims and scope Submit manuscript

Abstract

Purpose

Refractive artifacts are frequently encountered in clinical settings, and they have been analyzed on the basis of conventional two-dimensional (2-D) ultrasound (US) images, but this method is restricted to monoplane data and is limited by its inability to assess the three-dimensional (3-D) structure of refractive artifacts. The aim of this study was to evaluate the role of reconstructed 3-D US images in the analysis of refractive artifacts.

Methods

The following representative refractive artifacts were analyzed on the basis of reconstructed 3-D US images: (a) a distorted image of a fine tube behind a cyst (balloon); (b) a deformed image of the bottom of a balloon; and (c) a duplication artifact due to the acoustic lens effect.

Results

(a) A tube was imaged as a fine echogenic line with two points of sudden interruption, unlike a curved needle, which was imaged without interruption. (b) 3-D US allowed us to visualize the mode of deformity in the image of the bottom of a fluid-filled balloon in a water bath. When the acoustic velocity in the fluid was greater than that in the surrounding water, the bottom of the balloon appeared to be shrunken. When the acoustic velocity in the fluid was less than that in the surrounding water, the bottom of the balloon appeared to be swollen. (c) When we placed two pieces of white chicken meat in front of a fine needle, the needle was duplicated in the resulting image. In this case, the needle appeared to be vague and fuzzy. In this case, 3-D US did not add further information to the 2-D images.

Conclusions

Our study suggests that reconstructed 3-D US images provide a better understanding of the mode of refractive artifacts than do 2-D US images.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. KA Scanlan (1991) ArticleTitleSonographic artifacts and their origins AJR Am J Roentgenol 156 1267–72 Occurrence Handle1:STN:280:By6B38fpsVA%3D Occurrence Handle2028876

    CAS  PubMed  Google Scholar 

  2. WR Hedrick DL Hykes DE Starchman (1995) Images artifacts WR Hedrick DL Hykes DE Starchman (Eds) Ultrasound physics and instrumentation Mosby St Louis 314–29

    Google Scholar 

  3. MC Ziskin PS Lafolette K Blathras et al. (1990) ArticleTitleEffect of scan format on refraction artifacts Ultrasound Med Biol 16 183–91 Occurrence Handle10.1016/0301-5629(90)90147-5 Occurrence Handle1:STN:280:By%2BB38zovVw%3D Occurrence Handle2183462

    Article  CAS  PubMed  Google Scholar 

  4. H Ishida H Yagisawa P Morikawa et al. (1988) ArticleTitleSigne du drapeau: nouvel aspect echographique de la cirrhose macronodular JEMU 9 133–8

    Google Scholar 

  5. H Ishida H Yagisawa H Naganuma et al. (1996) ArticleTitleRotation of the diaphragmatic echo behind the liver tumor: clinical significance and computer analysis Eur J Ultrasound 3 267–75 Occurrence Handle10.1016/0929-8266(95)00159-X

    Article  Google Scholar 

  6. K Konno H Ishida A Uno et al. (1997) ArticleTitleAccuracy of liver puncture under US guidance: re-evaluation by microcomputer simulation model J Clin Ultrasound 25 127–32 Occurrence Handle10.1002/(SICI)1097-0096(199703)25:3<127::AID-JCU5>3.0.CO;2-I Occurrence Handle1:STN:280:ByiB3M7is1c%3D Occurrence Handle9058261

    Article  CAS  PubMed  Google Scholar 

  7. A Uno H Ishida K Konno et al. (2001) ArticleTitlePost-tumoral disturbed vascular image: diagnostic problem of sonogram J Med Ultrasound 28 89–96

    Google Scholar 

  8. A Uno H Ishida K Konno et al. (2003) ArticleTitleErrors in measuring blood flow velocity behind hepatic mass lesions using color Doppler sonography J Med Ultrasonics 30 133–40

    Google Scholar 

  9. K Konno H Ishida T Komatsuda et al. (2003) ArticleTitleImage distortion in US-guided liver tumor puncture with curbed linear array Eur Radiol 13 1291–6 Occurrence Handle12764644

    PubMed  Google Scholar 

  10. DH Pretorius TR Nelson JS Jaff (1992) ArticleTitle3-D dimensional sonographic analysis based on color flow Doppler and gray scale image data: a preliminary report J Ultrasound Med 11 225–32 Occurrence Handle1:STN:280:By2B28bktFQ%3D Occurrence Handle1588693

    CAS  PubMed  Google Scholar 

  11. RN Rankin A Fenster DB Downey (1993) ArticleTitleThree-dimensional sonographic reconstruction: techniques and diagnostic applications AJR Am J Roentgenol 161 695–702 Occurrence Handle1:STN:280:ByyA1cznslQ%3D Occurrence Handle8372741

    CAS  PubMed  Google Scholar 

  12. UM Hamper V Trapanotto S Sheth (1994) ArticleTitleThree-dimensional US: preliminary clinical experience Radiology 191 397–401 Occurrence Handle1:STN:280:ByuB3cvitFQ%3D Occurrence Handle8153312

    CAS  PubMed  Google Scholar 

  13. A Moskalik PL Carson CR Meyer et al. (1995) ArticleTitleRegistration of three-dimensional compound ultrasound scan of the breast for refraction and motion correction Ultrasound Med Biol 21 769–78 Occurrence Handle10.1016/0301-5629(95)00018-M Occurrence Handle1:STN:280:BymD2cfmvFQ%3D Occurrence Handle8571465

    Article  CAS  PubMed  Google Scholar 

  14. L Mercier T Lango F Lindeth et al. (2005) ArticleTitleA review of calibration techniques for freehand 3-D ultrasound systems J Ultrasound Med 31 449–71

    Google Scholar 

  15. AH Andreassen I Ellingsen LB Nesje et al. (2005) ArticleTitle3-D endobronchial ultrasonography: a post mortem study J Ultrasound Med 31 473–6

    Google Scholar 

  16. QH Huang YP Zheng (2005) ArticleTitleA new scanning approach for limb extremities using a water bag in freehand 3-D ultrasound J Ultrasound Med 31 575–83 Occurrence Handle1:STN:280:DC%2BD2M7pvVCrsQ%3D%3D

    CAS  Google Scholar 

  17. HX Xu XY Yin (2003) ArticleTitleComparison of three-and two-dimensional sonography in diagnosis of gallbladder diseases J Ultrasound Med 22 181–91 Occurrence Handle12562123

    PubMed  Google Scholar 

  18. HX Xu L Liu MD Liu et al. (2003) ArticleTitleThree- and two-dimensional power Doppler imaging in depicting vascularity in hepatocellular carcinoma J Ultrasound Med 22 1147–54 Occurrence Handle14620884

    PubMed  Google Scholar 

  19. HX Xu XY Yin MD Lu et al. (2003) ArticleTitleUsefulness of three-dimensional sonography in procedures of ablation for liver cancer: initial experience J Ultrasound Med 22 1239–47 Occurrence Handle14620896

    PubMed  Google Scholar 

  20. A Kobayashi T Yamaguchi T Ishihara et al. (2005) ArticleTitleAssessment of portal vein invasion in pancreatic cancer by fusion 3-dimensional ultrasonography J Ultrasound Med 24 363–9 Occurrence Handle15723849

    PubMed  Google Scholar 

  21. AH Bhat V Corbett N Carpenter et al. (2004) ArticleTitleFetal ventricular mass determination on three-dimensional echocardiography: studies in normal fetuses and validation experiments Circulation 110 1054–60 Occurrence Handle10.1161/01.CIR.0000139848.33468.22 Occurrence Handle15326076

    Article  PubMed  Google Scholar 

  22. A Tsutsui S Okamura N Muguruma et al. (2005) ArticleTitleThree-dimensional reconstruction of endosonographic images of gastric lesions: preliminary experience J Clin Ultrasound 33 112–8 Occurrence Handle10.1002/jcu.20100 Occurrence Handle15756663

    Article  PubMed  Google Scholar 

  23. AZ Abhamad (2005) ArticleTitleStandarization of 3-dimensional volumes in obstetric sonography J Ultrasound Med 24 397–401

    Google Scholar 

  24. AC Fleischer MR Milam MA Crispens et al. (2005) ArticleTitleSonographic depiction of intratumoral vascularity with 2-and 3-dimensional color Doppler techniques J Ultrasound Med 24 533–7 Occurrence Handle15784771

    PubMed  Google Scholar 

  25. JE Bailey RO Bude T Tuthill (2001) ArticleTitleUS artifacts: effects on out-of-plane US images reconstructed from three-dimensional data sets Radiology 218 592–7 Occurrence Handle1:STN:280:DC%2BD3M3lvVehtA%3D%3D Occurrence Handle11161184

    CAS  PubMed  Google Scholar 

  26. Y Yoshida N Kato H Ishida et al. (1991) ArticleTitleMeasurement of sound velocity in soft tissues using sing-around method Jpn J Med Ultrasonics 58 IssueIDSuppl 559–60

    Google Scholar 

  27. SA Goss RL Johnston F Dunn (1978) ArticleTitleComprehensive compilation of empirical ultrasonic properties of mammalian tissues J Acoust Soc Am 64 423–57 Occurrence Handle10.1121/1.382016 Occurrence Handle1:STN:280:CSaD2cfptlI%3D Occurrence Handle361793

    Article  CAS  PubMed  Google Scholar 

  28. L Weng AP Tirumalai CM Lowery et al. (1997) ArticleTitleUS extended-field-of-view imaging technology Radiology 203 877–80 Occurrence Handle1:STN:280:ByiA3MzhtFI%3D Occurrence Handle9169720

    CAS  PubMed  Google Scholar 

  29. H Ishida K Konno T Komatsuda et al. (1999) ArticleTitleMultinodular fatty change in the liver in patients with chronic hepatic porphyria Abdom Imaging 24 481–3 Occurrence Handle1:STN:280:DyaK1Mvgs1Crsw%3D%3D Occurrence Handle10475932

    CAS  PubMed  Google Scholar 

  30. WR Hedrick DL Hykes DE Starchman (1995) Basic ultrasound physics WR Hedrick DL Hykes DE Starchman (Eds) Ultrasound physics and instrumentation Mosby St Louis 1–30

    Google Scholar 

  31. RB Jeffrey SuffixJr PW Ralls (1995) The liver RB Jeffrey SuffixJr PW Ralls (Eds) Sonography of the abdomen Raven Press New York 71–178

    Google Scholar 

  32. RB Jeffrey SuffixJr PW Ralls (1995) The spleen RB Jeffrey SuffixJr PW Ralls (Eds) Sonography of the abdomen Raven Press New York 359–88

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hideaki Ishida.

About this article

Cite this article

Sato, M., Ishida, H., Konno, K. et al. Analysis of refractive artifacts by reconstructed three-dimensional ultrasound imaging. J Med Ultrasonics 33, 11–16 (2006). https://doi.org/10.1007/s10396-005-0072-9

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10396-005-0072-9

Key words