Skip to main content
Log in

Antegradely insertable aortic balloon occlusion catheter for aortic arch repair

  • ORIGINAL ARTICLE
  • Published:
Heart and Vessels Aims and scope Submit manuscript

Abstract

 We have developed an antegradely insertable aortic balloon occlusion catheter for aortic arch repair, and review our experiences of using it. The purpose of the present study was to examine the usefulness of the balloon for surgical treatment of aortic arch aneurysm. In 30 patients with aortic arch aneurysm, including 22 with a non-ruptured and 8 with a ruptured aneurysm, the catheter was antegradely inserted into the descending thoracic aorta through the aortic arch or the aneurysm without opening the pleural space after establishing antegrade selective cerebral perfusion and obtaining cardiac arrest. During distal anastomosis, the catheter occluded the aorta with continuous perfusion of the lower half of the body through an arterial cannula inserted into the femoral artery. Among the patients with a nonruptured aneurysm, two deaths (9.1%) occurred because of aorto-broncho-esophageal fistulae or cardiac arrest due to severe asthma attack within 30 days, and the other three hospital deaths were due to aspiration pneumonia, multiple organ failure with preoperative renal dysfunction, or low cardiac output syndrome due to perioperative myocardial infarction. Among the patients with a ruptured aneurysm, three deaths (37.5%) were due to acute myocardial infarction, respiratory failure, or intractable arrhythmia within 30 days, and another hospital death was caused by mediastinitis. No paraplegia was caused in any patient excluding one of the patients with a ruptured aneurysm who could not be weaned from the extracorporeal circulation due to perioperative myocardial infarction. There was no early postoperative serious visceral organ dysfunction except for two patients with postoperative low cardiac output syndrome or preoperative severe renal dysfunction. This catheter was effective in protecting the visceral organs and the spinal cord in the repair of an aortic arch aneurysm.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: March 7, 2002 / Accepted: November 29, 2002

Rights and permissions

Reprints and permissions

About this article

Cite this article

Takagi, H., Hirose, H., Mori, Y. et al. Antegradely insertable aortic balloon occlusion catheter for aortic arch repair. Heart Vessels 18, 75–78 (2003). https://doi.org/10.1007/s10380-002-0688-3

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10380-002-0688-3

Navigation